The influence factors of SO2 removal in flue gas with a pulsed corona discharge

被引:0
|
作者
Li, J. [1 ]
Wu, Y. [1 ]
Wang, N. [1 ]
Li, G. [1 ]
Zhang, Y. [1 ]
机构
[1] Inst. of Electrostat./Specific Power, Dalian University of Technology, Dalian 116024, China
来源
Huanjing Kexue/Environmental Science | 2001年 / 22卷 / 05期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The influence of the operation parameters on SO2 removal rate with a pulsed corona discharge was studied in this paper, in order to promote the industrial applications of this technology. The flow rate of the flue gas was 1000 [similar to] 3000 m3/h. The SO2 removal rate reached 80%. The range of SO2 concentration in flue gas was 1000 [similar to] 2000 ml/m3. The flue gas temperature was 60°C [similar to] 80°C. The molecule ratio of NH3 to SO2 was 2. The energy consumption was 3 [similar to] 5W·h/Nm3. The wire-plane electrode structure and a positive high voltage pulse power supply were used in the experiment.
引用
收藏
页码:38 / 40
相关论文
共 50 条
  • [1] Electric discharge removal of SO2 and NOx from combustion flue gas by pulsed corona discharge
    Toyohashi Univ of Technology, Aichi, Japan
    Energy Convers Manage, 10-13 (1377-1387):
  • [2] Electric discharge removal of SO2 and NOx from combustion flue gas by pulsed corona discharge
    Onda, K
    Kasuga, Y
    Kato, K
    Fujiwara, M
    Tanimoto, M
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (10-13) : 1377 - 1387
  • [4] SO2 removal from industrial flue gases using pulsed corona discharge
    Wu, Y
    Wang, NH
    Zhu, YM
    Zhang, YB
    JOURNAL OF ELECTROSTATICS, 1998, 44 (1-2) : 11 - 16
  • [5] Influence of electrode configuration on energy utilization for SO2 removal in flue gas with pulsed corona plasma
    Dong, BY
    Li, GF
    Wu, Y
    Li, J
    CONFERENCE RECORD OF THE 2004 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4: COVERING THEORY TO PRACTICE, 2004, : 250 - 253
  • [6] Removal of NO and SO2 by pulsed corona discharge process
    Young Sun Mok
    Ho Won Lee
    Young Jin Hyun
    Sung Won Ham
    Jae Hak Kim
    In-Sik Nam
    Korean Journal of Chemical Engineering, 2001, 18 : 308 - 316
  • [7] Removal of NO and SO2 by pulsed corona discharge process
    Mok, YS
    Lee, HW
    Hyun, YJ
    Ham, SW
    Kim, JH
    Nam, IS
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2001, 18 (03) : 308 - 316
  • [8] Removal of SO2 from flue gas by water vapor DC corona discharge
    Division of Basic Courses, Shanghai Maritime University, Shanghai 200135, China
    不详
    Huanjing Kexue, 2006, 7 (1282-1285):
  • [9] Removal of NOx and SO2 in flue gas by corona discharge reactor with water film
    Dong, LM
    Sheng, SG
    Liu, LT
    Yang, JX
    Chi, XC
    2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2002, : 774 - 777