Causes analysis and treatment of damage in a shallow buried box metro tunnel

被引:0
|
作者
机构
[1] Liu, Ting-Jin
[2] Xia, Wen-Yu
[3] Zhou, Shu-Yang
[4] Cai, Ren-Xian
来源
Liu, Ting-Jin | 1600年 / Editorial Department of Journal of Railway Engineering Society, China卷 / 33期
关键词
Deformation; -; Diseases; Subways; Tunneling; (excavation); Groundwater;
D O I
暂无
中图分类号
学科分类号
摘要
Research purposes: Some damages such as leakage in deformation joint, disengaging and transverse cracks in ballast, water and sand gushing of ballast, have been found in the shallow buried box metro tunnel, which caused by excavation of adjacent deep foundation pit. In this paper, overview of the metro tunnel disease accident is researched, and then the main disease and distribution are sorted, at last, causes of tunnel disease are deeply investigated which provide reference for damage treatment. Research conclusions: (1) The structural differential settlement of tunnel is the main reason of leakage in deformation joint. Meanwhile, it is the important reason of disengaging, transverse cracks, water and sand gushing in ballast. (2) The compression of layer leads to huge and uneven settlement of tunnel structure which caused by the decrease of groundwater level. (3) As the shallow buried tunnel is weak to resist the excavation disturbance of adjacent foundation pit, ground fissure occurred above the metro tunnel caused by uncoordinated horizontal deformation between ground and tunnel structure, which will aggravate the tunnel leakage. (4) The reasonable treatment scheme of grouting reinforcement has been proposed. (5) The conclusion could be used for reference of similar engineering of metro tunnel. © 2016, Editorial Department of Journal of Railway Engineering Society. All right reserved.
引用
收藏
相关论文
共 50 条
  • [31] Disaster-induced mechanism and its treatment in shallow-buried karst tunnel
    Kang, Yong
    Yang, Chunhe
    Zhang, Peng
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2010, 29 (01): : 149 - 154
  • [32] Influence of Support Parameter and Excavation Methods on Statistical Distribution Characteristics of Surrounding Rock Pressure in Shallow-Buried Metro Tunnel
    Chen, Song
    Yang, Zhao
    Zheng, Yibo
    Yuan, Ying
    Sun, Jinglai
    Li, Liufang
    ADVANCES IN CIVIL ENGINEERING, 2023, 2023
  • [33] Analyzing the Causes of Tread Damage in Metro Vehicles
    Zhou, Chunmei
    Yue, Liming
    Yao, Fenglong
    Guo, Baili
    RESILIENCE AND SUSTAINABLE TRANSPORTATION SYSTEMS: PROCEEDINGS OF THE 13TH ASIA PACIFIC TRANSPORTATION DEVELOPMENT CONFERENCE, 2020, : 506 - 511
  • [34] Response of buried box-shaped road tunnel against internal BLEVE and its damage mitigation
    Cheng, Ruishan
    Chen, Wensu
    Hao, Hong
    Li, Jingde
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 138
  • [35] Damage analysis of urban metro tunnel under strike-slip fault
    Zhao, Ying
    Guo, En-Dong
    Liu, Zhi
    Gao, Lin
    Yantu Lixue/Rock and Soil Mechanics, 2014, 35 : 467 - 473
  • [36] Damage analysis of urban metro tunnel under strike-slip fault
    Zhao Ying
    Guo En-dong
    Liu Zhi
    Gao Lin
    ROCK AND SOIL MECHANICS, 2014, 35 : 467 - 473
  • [37] The control of building load on the shallow foundations close to the metro tunnel
    Chen, Bin
    Ye, Junneng
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 1287 - 1290
  • [38] Large deformation characteristics and mechanism analysis of excavating shallow buried tunnel in reclamation areas
    Gong, Huimin
    Xue, Yiguo
    Han, Min
    Kong, Fanmeng
    Fu, Kang
    Jiang, Xudong
    BULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT, 2025, 84 (01)
  • [39] The Application of the Strength Reduction Shortest Path Method to the Stability Analysis of Shallow Buried Tunnel
    Wei Wang
    Jiaqi Zhang
    Ao Li
    Geotechnical and Geological Engineering, 2022, 40 : 1091 - 1101
  • [40] Analysis of land subsidence deformation caused by urban shallow-buried tunnel construction
    Wang, Donglin, 1600, Bentham Science Publishers B.V., P.O. Box 294, Bussum, 1400 AG, Netherlands (08):