Evaluationof high-voltage circuit breaker interruption resource

被引:0
|
作者
Stognii B.S. [1 ]
Sopel M.F. [1 ]
Tretiakova L.D. [2 ]
Tankevych E.M. [1 ]
Panov A.V. [1 ]
Pankiv V.I. [1 ]
机构
[1] Institute of Electrodynamics of the National Academy of Sciences of Ukraine, Peremohy pr., 56, Kyiv
[2] National Technical University of Ukraine 'Kyiv Polytechnic Institute', Pr. Peremohy, 37, Kyiv
来源
Panov, A.V. (av-panov@yandex.ru) | 1600年 / Institute of Electrodynamics, National Academy of Sciences of Ukraine卷 / 2017期
关键词
Approximation; Current transformer; Current transformerhigh-voltage circuit breaker; High-voltage circuit breaker; Interrupted current; Interruption resource;
D O I
10.15407/techned2017.01.071
中图分类号
学科分类号
摘要
The overall effect of precision of interruption curve approximation, accuracy of current measurement and evaluation of root-mean-square value of circuit breaker interrupted current on precision its switching resource under condition was investigated. Based on the results of several ways of approximation of interruption curve of circuit breaker, using different amount of points, given by manufacturer, the conditions of qualitative and accurate approximation of such curve were identified. ABB HPL 362 B1 circuit breaker was considered as example and it was shown that one of the possible ways to increase the accuracy and improve technology of circuit breaker interruption resource evaluation is its resource curve approximation by using cubic spline and improving the accuracy of measurement of instantaneous values of fault currents in the period of interruption of fault currents.
引用
收藏
页码:71 / 80
页数:9
相关论文
共 50 条
  • [21] Interruption of inductive load currents with high-voltage circuit breakers
    Shleyfman I.L.
    Power Technology and Engineering, 2014, 48 (1) : 71 - 73
  • [22] The Voltage Distribution Characteristics of a Hybrid Circuit Breaker During High Current Interruption
    程显
    段雄英
    廖敏夫
    黄智慧
    罗彦
    邹积岩
    Plasma Science and Technology, 2013, (08) : 800 - 806
  • [23] The Voltage Distribution Characteristics of a Hybrid Circuit Breaker During High Current Interruption
    程显
    段雄英
    廖敏夫
    黄智慧
    罗彦
    邹积岩
    Plasma Science and Technology, 2013, 15 (08) : 800 - 806
  • [24] The Voltage Distribution Characteristics of a Hybrid Circuit Breaker During High Current Interruption
    Cheng Xian
    Duan Xiongying
    Liao Minfu
    Huang Zhihui
    Luo Yan
    Zou Jiyan
    PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (08) : 800 - 806
  • [25] Optimal dimensional synthesis of the trigger mechanism of a high-voltage circuit breaker
    Yu, Ming-Jung
    Wang, Li-Chun
    Huang, Shyh-Chin
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2013, 36 (02) : 146 - 156
  • [26] Review of Topologies for Medium- and High-voltage DC Circuit Breaker
    Wang C.
    Du C.
    Xu J.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (09): : 187 - 199
  • [27] Dynamic simulation of a high-voltage circuit breaker considering the mechanical efficiency
    Kim, Jae Yeol
    Kim, Jin Ho
    Kim, Hyun Woo
    Kim, Byung Hun
    Lee, Sung Ho
    Lee, Kun Ho
    Bae, Byung Tae
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 415 - 417
  • [28] Dynamic simulation of high-voltage circuit breaker concerning electrodynamic force
    Yang, Wu
    Rong, Ming-Zhe
    Wang, Xiao-Hua
    Jia, Shen-Li
    Chen, De-Gui
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (05): : 103 - 107
  • [29] Experiment and CFD simulation of exhaust tube in high-voltage circuit breaker
    Ye, Xiangyang
    Pisu, Francesco
    Grob, Stephan
    Dhotre, Mahesh
    Mantilla, Javier
    SIXTH INTERNATIONAL MULTI-CONFERENCE ON ENGINEERING AND TECHNOLOGY INNOVATION 2017 (IMETI 2017), 2018, 169
  • [30] A novel smart high-voltage circuit breaker for smart grid applications
    State Key Laboratory of Electrical Insulation and Power Equipments, Department of Electrical Engineering, Xi'An Jiaotong University, Xi'an, Shaanxi 710049, China
    不详
    IEEE Trans. Smart Grid, 1949, 2 (254-264):