Novel optimized models to enhance performance forecasting of grid-connected PERC PV string operating under semi-arid climate conditions

被引:0
|
作者
El Ainaoui, Khadija [1 ,2 ]
Zaimi, Mhammed [1 ]
Flouchi, Imane [2 ]
Elhamaoui, Said [2 ]
El Mrabet, Yasmine [2 ]
Ibaararen, Khadija [1 ]
Bouasria, Youssef [1 ]
Ghennioui, Abdellatif [2 ]
Assaid, El Mahdi [1 ]
机构
[1] Chouaib Doukkali Univ, Dept Phys, Lab Instrumentat Measure & Control, Fac Sci,Elect & Opt Semicond Nanostruct & Sustaina, El Jadida, Morocco
[2] Green Energy Pk, Elect Syst & Photovolta Dept, Benguerir, Morocco
关键词
PV string; PERC; Single diode model; Explicit models; Power forecasting; I -V characteristics; J-V MODEL; SINGLE-DIODE MODEL; SOLAR-CELL; MAXIMUM POWER; PARAMETERS; TRANSLATION; TEMPERATURE; IMPROVEMENT; EFFICIENCY; CURVE;
D O I
10.1016/j.solener.2024.112976
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study focuses on modeling and forecasting the performance of a grid-connected photovoltaic (PV) string, aiming to enhance the accuracy of output power prediction, which is crucial for the effective management and stability of the electrical grid. While previous research has extensively examined PV modules, there is a notable lack of studies specifically targeting PV string behaviors, especially in harsh climates prevailing in semi-arid regions. This study addresses this gap by investigating the modeling and performance prediction of a Passivated Emitter Rear Cell (PERC) PV string under semi-arid climate conditions using analytical and predictive approaches based on both implicit and explicit models as Single Diode Model (SDM), Das Model (DM), Boutana et al. Model (BM) and Power Law Model (PLM). New mathematical models of DM and BM shape parameters versus temperature and irradiance along with novel analytical formulas giving DM shape parameters as a function of PV metrics have been introduced. The proposed approaches are validated using real measurements of a PERC PV string incorporating 12 JKM405M-72H PV modules operating at Green Energy Park (GEP) research facility in Morocco. The reliability of these approaches is assessed by comparing I-V curves, P-V curves and peak power generated and predicted by SDM, DM, BM and PLM to actual measurements. The comparison reveals that generated and predicted outcomes align well with measured data, with an average value of Normalized Root Mean Square Error (NRMSE) not exceeding 4.16 % for all models throughout the day. The findings indicate that the proposed approaches effectively predict the performance of the PERC PV string, accounting for climatic influences and providing insights into optimizing PV system performance, thereby contributing to improved grid stability in semi-arid regions.
引用
收藏
页数:13
相关论文
共 22 条
  • [21] A Novel Modified Sine-Cosine Optimized MPPT Algorithm for Grid Integrated PV System under Real Operating Conditions
    Padmanaban, Sanjeevikumar
    Priyadarshi, Neeraj
    Holm-Nielsen, Jens Bo
    Bhaskar, Mahajan Sagar
    Azam, Farooque
    Sharma, Amarjeet Kumar
    Hossain, Eklas
    IEEE ACCESS, 2019, 7 : 10467 - 10477
  • [22] Effects of Genotype and Climate on Productive Performance of High Oleic Carthamus tinctorius L. under Rainfed Conditions in a Semi-Arid Environment of Sicily (Italy)
    Licata, Mario
    Farruggia, Davide
    Iacuzzi, Nicolo
    Matteo, Roberto
    Tuttolomondo, Teresa
    Di Miceli, Giuseppe
    PLANTS-BASEL, 2023, 12 (09):