Novel optimized models to enhance performance forecasting of grid-connected PERC PV string operating under semi-arid climate conditions

被引:0
|
作者
El Ainaoui, Khadija [1 ,2 ]
Zaimi, Mhammed [1 ]
Flouchi, Imane [2 ]
Elhamaoui, Said [2 ]
El Mrabet, Yasmine [2 ]
Ibaararen, Khadija [1 ]
Bouasria, Youssef [1 ]
Ghennioui, Abdellatif [2 ]
Assaid, El Mahdi [1 ]
机构
[1] Chouaib Doukkali Univ, Dept Phys, Lab Instrumentat Measure & Control, Fac Sci,Elect & Opt Semicond Nanostruct & Sustaina, El Jadida, Morocco
[2] Green Energy Pk, Elect Syst & Photovolta Dept, Benguerir, Morocco
关键词
PV string; PERC; Single diode model; Explicit models; Power forecasting; I -V characteristics; J-V MODEL; SINGLE-DIODE MODEL; SOLAR-CELL; MAXIMUM POWER; PARAMETERS; TRANSLATION; TEMPERATURE; IMPROVEMENT; EFFICIENCY; CURVE;
D O I
10.1016/j.solener.2024.112976
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study focuses on modeling and forecasting the performance of a grid-connected photovoltaic (PV) string, aiming to enhance the accuracy of output power prediction, which is crucial for the effective management and stability of the electrical grid. While previous research has extensively examined PV modules, there is a notable lack of studies specifically targeting PV string behaviors, especially in harsh climates prevailing in semi-arid regions. This study addresses this gap by investigating the modeling and performance prediction of a Passivated Emitter Rear Cell (PERC) PV string under semi-arid climate conditions using analytical and predictive approaches based on both implicit and explicit models as Single Diode Model (SDM), Das Model (DM), Boutana et al. Model (BM) and Power Law Model (PLM). New mathematical models of DM and BM shape parameters versus temperature and irradiance along with novel analytical formulas giving DM shape parameters as a function of PV metrics have been introduced. The proposed approaches are validated using real measurements of a PERC PV string incorporating 12 JKM405M-72H PV modules operating at Green Energy Park (GEP) research facility in Morocco. The reliability of these approaches is assessed by comparing I-V curves, P-V curves and peak power generated and predicted by SDM, DM, BM and PLM to actual measurements. The comparison reveals that generated and predicted outcomes align well with measured data, with an average value of Normalized Root Mean Square Error (NRMSE) not exceeding 4.16 % for all models throughout the day. The findings indicate that the proposed approaches effectively predict the performance of the PERC PV string, accounting for climatic influences and providing insights into optimizing PV system performance, thereby contributing to improved grid stability in semi-arid regions.
引用
收藏
页数:13
相关论文
共 22 条
  • [1] Analytical assessment of Ain Skhouna PV plant performance connected to the grid under a semi-arid climate in Algeria
    Ihaddadene, Razika
    Jed, Mohamed El Hassen
    Ihaddadene, Nabila
    De Souza, Amaury
    SOLAR ENERGY, 2022, 232 : 52 - 62
  • [2] MPPT Performance of a Grid-connected PV Inverter under Malaysian Conditions
    Azli, N. A.
    Salam, Z.
    Jusoh, A.
    Facta, M.
    Lim, B. C.
    Hossain, S.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 457 - +
  • [3] A Novel Hybrid Control Strategy for Grid-Connected PV- Battery System under Different Operating Conditions
    Pandey, Pawan Kumar
    El Khatib, Ziad
    Kumar, Ramesh
    Singla, Manish
    Safaraliev, Murodbek
    Kamalov, Firuz
    PRZEGLAD ELEKTROTECHNICZNY, 2024, 100 (09): : 287 - 291
  • [4] Outdoor performance analysis of different PV technologies under hot semi-arid climate
    Nour-eddine, Id Omar
    Lahcen, Boukhattem
    Fahd, Oudrhiri Hassani
    Amin, Bennouna
    Aziz, Oukennou
    ENERGY REPORTS, 2020, 6 : 36 - 48
  • [5] Evaluation, comparison and experimental validation of different PV power prediction models under semi-arid climate
    Hajjaj, Charaf
    Merrouni, Ahmed Alami
    Bouaichi, Abdellatif
    Benhmida, Mohammadi
    Sahnoun, Smail
    Ghennioui, Abdellatif
    Zitouni, Houssain
    ENERGY CONVERSION AND MANAGEMENT, 2018, 173 : 476 - 488
  • [6] Thermal performance analysis of a poly c-Si PV module under semi-arid conditions
    Lamaamar I.
    Tilioua A.
    Hamdi Alaoui M.A.
    Materials Science for Energy Technologies, 2022, 5 : 243 - 251
  • [7] Energy and exergy analysis of a 20-MW grid-connected PV plant operating under harsh climatic conditions
    Aoun, Nouar
    CLEAN ENERGY, 2024, 8 (01): : 281 - 296
  • [8] Experimental performance characterization and economic efficiency of 16.28 kwp grid-tied pv systems in semi-arid climate
    KHENNANE M.B.
    BOUGHALI S.
    BECHKI D.
    ZAGHBA L.
    FEZZANI A.
    MAHAMMED I.H.
    Diagnostyka, 2021, 22 (02): : 53 - 65
  • [9] Performance evaluation of a locally modified PV module to a PV/T solar collector under climatic conditions of semi-arid region
    Boumaaraf, Billel
    Boumaaraf, Houria
    Slimani, Mohamed El-Amine
    Tchoketch-Kebir, Selma
    Ait-cheikh, Mohamed Salah
    Touafek, Khaled
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2020, 167 : 135 - 154
  • [10] A Novel Grid-Connected PV System Based on MMC to Get the Maximum Power Under Partial Shading Conditions
    Rong, Fei
    Xichang, Gong
    Huang, Shoudao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (06) : 4320 - 4333