Reflections on odour concentration fluctuations and nuisance

被引:0
|
作者
Sozzi R. [1 ]
Bolignano A. [1 ]
Sironi S. [2 ]
Capelli L. [2 ]
机构
[1] ARPA Lazio, via Boncompagni 101, Roma
[2] Politecnico di Milano, Department of Chemistry Materials and Chemical Engineering 'Giulio Natta', Piazza Leonardo da Vinci 32, Milano
来源
关键词
D O I
10.3303/CET1868034
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In general, odours are perceived by humans through a single respiratory act having a duration of approximately 5 seconds. Moreover, odour concentration varies almost randomly over time, as any other physical variable in a turbulent environment. For this reason, both field measurements and dispersion models used for odour impact assessment purposes should be able to refer to short sampling times, instead of considering concentrations averaged over prolonged periods (i.e. 1 hour). This paper has the aim to investigate the problem of odour concentration fluctuations and their correlation with odour nuisance, thereby briefly discussing the problem of turbulence based on some theoretical considerations and of a few experimental results. The experimental results relevant to the continuous monitoring of instantaneous H2S concentration in ambient air clearly show that peak concentration exceed 1-hour average concentrations by almost 1 order of magnitude. Finally, the paper discusses the possible implementation of a dispersion model specifically dedicated to odour nuisance evaluation, thereby investigating different solutions to account for concentration fluctuations. The investigation related to the peak-to-mean approach, currently being the most widely used method to evaluate peak concentrations from 1-hour averaged concentrations on a regulatory level, allowed to point out the drawbacks of this methodology, which, despite its simplicity and ease-of-use, is unable to accurately describe the concentration fluctuations phenomena. © 2018, AIDIC Servizi S.r.l.
引用
收藏
页码:199 / 204
页数:5
相关论文
共 50 条
  • [21] Application of in-home surveys to determine the odour nuisance in areas adjacent to industrial odour emission sources
    Sowka, Izabela
    Zwozdziak, Jerzy
    Nych, Alicja
    Szklarczyk, Miroslaw
    Skretowicz, Maria
    Zwozdziak, Pawel
    PRZEMYSL CHEMICZNY, 2010, 89 (04): : 546 - 549
  • [22] Separation distance to avoid odour nuisance due to livestock calculated by the Austrian odour dispersion model (AODM)
    Schauberger, G
    Piringer, M
    Petz, E
    AGRICULTURE ECOSYSTEMS & ENVIRONMENT, 2001, 87 (01) : 13 - 28
  • [23] Correlation between odour concentration and odour intensity from exposure to environmental odour
    Yusoff, Syafinah
    Zaman, Nastaein Qamaruz
    INTERNATIONAL RESEARCH AND INNOVATION SUMMIT (IRIS2017), 2017, 226
  • [24] ODOUR NUISANCE ACCOMPANYING HYPOLIMNETIC WITHDRAWAL METOD ON THE EXAMPLE OF THE KORTOWSKIE LAKE
    Brudniak, Andrzej
    Debowski, Marcin
    Zielinski, Marcin
    ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A, 2013, 20 (4-5): : 469 - 480
  • [25] A case study of odour nuisance evaluation in the context of integrated urban planning
    Badach, Joanna
    Kolasinska, Paulina
    Paciorek, Malgorzata
    Wojnowski, Wojciech
    Dymerski, Tomasz
    Gebicki, Jacek
    Dymnicka, Malgorzata
    Namiesnik, Jacek
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2018, 213 : 417 - 424
  • [26] Nuisance odour detection using a portable electronic nose and a preconcentration system
    Furlong, C
    Stewart, JR
    SENSORS FOR ENVIRONMENTAL CONTROL, 2003, : 163 - 167
  • [27] Assessing odour nuisance from wastewater treatment and composting facilities in Greece
    Lasaridi, Katia
    Katsabanis, George
    Kyriacou, Adamantini
    Maggos, Thomas
    Manios, Thrassyvoulos
    Fountoulakis, Mihalis
    Kalogerakis, Nicolas
    Karageorgos, Petros
    Stentiford, Edward Ian
    WASTE MANAGEMENT & RESEARCH, 2010, 28 (11) : 977 - 984
  • [28] Conversion of the chemical concentration of odorous mixtures into odour concentration and odour intensity: A comparison of methods
    Wu, Chuandong
    Liu, Jiemin
    Zhao, Peng
    Piringer, Martin
    Schauberger, Guenther
    ATMOSPHERIC ENVIRONMENT, 2016, 127 : 283 - 292
  • [29] Assessing the environmental impact of WWTP expansion: odour nuisance and its minimization
    Capodagllo, AG
    Conti, F
    Pelosi, G
    Urbini, G
    WATER SCIENCE AND TECHNOLOGY, 2002, 46 (4-5) : 339 - 346
  • [30] Odour nuisance and dispersion modelling: an objective approach to a very subjective problem
    Simms, KL
    Wilkinson, S
    Bethan, S
    WATER SCIENCE AND TECHNOLOGY, 2000, 41 (06) : 89 - 96