Determination of meconium lead level of newborn by graphite furnace atomic absorption spectrometry

被引:0
|
作者
Li, Yan [1 ]
Xu, Xi-Jin [1 ]
Liu, Jun-Xiao [1 ]
Zheng, Liang-Kai [1 ]
Chen, Gang-Jian [1 ]
Chen, Song-Jian [1 ]
Huo, Xia [1 ]
机构
[1] Central Laboratory, Medical College, Shantou University, Shantou 515031, China
关键词
Atomic absorption spectrometry - Graphite - Hydrogen peroxide - Lead - Nitric acid;
D O I
暂无
中图分类号
学科分类号
摘要
To establish a method for the determination of lead in meconium from 144 samples of newborn through nitric acid digestion by means of graphite furnace atomic absorption spectrometry. Methods: After being baked for at least 12 h at 60°C, 0.3 g of meconium was digested by nitric acid and hydrogen peroxide in turn at 80°C under water-bath condition for 1 h and then metered to the whole volume of to 2 mL. After correcting the background with D2 lamp, specimen basal corpuscle matched standard curve was used to detect the lead content. Results: The mean lead content of 93 experimental samples was 1.934μg&middotg-1 with the standard deviation (SD) of 1.551, and that of the 51 control samples was 1.012μg&middotg-1, with the SD of 1.084. There was a significant difference in lead levels of in meconnt between the experimental group and control group (p = 0.000). Conclusion: The lead content of the experimental was significantly higher than that of the control group detected by this method. This method was stable and efficient.
引用
收藏
页码:447 / 449
相关论文
共 50 条
  • [41] The determination of low lead levels in the bone of lead-depleted mice by graphite furnace atomic absorption spectrometry
    Iavicoli, I
    Carelli, G
    Castellino, N
    Schlemmer, G
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (08): : 1100 - 1104
  • [42] Sensitive and Direct Determination of Lead in Coffee Drinks by Graphite Furnace Atomic Absorption Spectrometry After In-Furnace Digestion
    Qiu, Wei
    Zhang, Yue
    Xu, Yuming
    Su, Qingping
    Liu, Rui
    Li, Chongying
    ATOMIC SPECTROSCOPY, 2014, 35 (06) : 260 - 264
  • [43] Determination of Ni in biological samples with graphite furnace atomic absorption spectrometry
    Li, HT
    Lu, D
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (04) : 545 - 546
  • [44] Lead Determination in Chinese Herbal Medicine by Graphite Furnace Atomic Absorption Spectrometry using Matrix Modifier
    Feng, Shaoping
    Huang, Zhaolong
    Yi, Ping
    Wu, Na
    Wang, Zefeng
    Liu, Wei
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ITS APPLICATION, 2012, 485 : 119 - 122
  • [45] The effect of "matrix modifiers" on the determination of lead in children milk powder by graphite furnace atomic absorption Spectrometry
    Alexiu, V
    Vladescu, L
    REVISTA DE CHIMIE, 2003, 54 (05): : 406 - 410
  • [46] Single drop microextraction combined with graphite furnace atomic absorption spectrometry for determination of lead in biological samples
    Pei Liang
    Rui Liu
    Jing Cao
    Microchimica Acta, 2008, 160 : 135 - 139
  • [47] Determination of Chromium, Copper, Iron, Manganese and Lead in Human Hair by Graphite Furnace Atomic Absorption Spectrometry
    Xiaonan Dong
    Yuzuru Nakaguchi
    Keizo Hiraki
    Analytical Sciences, 1998, 14 : 785 - 789
  • [48] Determination of lead in grape wine by graphite furnace atomic absorption spectrometry with ammonium dihydric phosphate as modifier
    Zuo, ZY
    Zhang, M
    Sun, ZA
    Wang, DS
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2002, 22 (05) : 859 - 861
  • [49] Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction
    Chen, JR
    Xiao, SM
    Wu, XH
    Fang, KM
    Liu, WH
    TALANTA, 2005, 67 (05) : 992 - 996
  • [50] Single drop microextraction combined with graphite furnace atomic absorption spectrometry for determination of lead in biological samples
    Liang, Pei
    Liu, Rui
    Cao, Jing
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 135 - 139