Two Independent Single-Loop Voltage Mode Control Method for 3-Level Buck Converter

被引:0
|
作者
Jeong, June-Bong [1 ]
Kim, Chan-Gyu [1 ]
Kang, Jeong-Il [2 ]
Han, Sang-Kyoo [1 ]
机构
[1] Kookmin Univ, Coll Creat Engn, Power Elect Syst Lab POESLA, Seoul 02707, South Korea
[2] Samsung Elect Co LTD, Suwon 16677, Gyeonggi, South Korea
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Buck converters; Capacitors; Inductors; Circuits; Transfer functions; Stress measurement; Control systems; Switches; Sensors; Voltage control; Converters; 3-level buck converter; high efficiency; high power density; slim converter; voltage mode control;
D O I
10.1109/ACCESS.2024.3476409
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Compared to a basic buck converter, the 3-level buck converter operates with the output inductor at twice the switching frequency. Additionally, the voltage across its flying capacitor contributes to reducing the slope of the inductor current. These factors can result in a reduction in the maximum output current ripple by up to four times, enabling the use of a smaller output inductor. Moreover, the voltage stress on the switches is only half of the input voltage. Therefore, the 3-level buck converter is advantageous for achieving high efficiency and high power density. To maintain these advantages, the voltage across the flying capacitor must be kept at half of the input voltage. Conventionally, this condition is usually ensured by using peak or valley current mode control methods. However, these methods have complex control circuits or algorithms and are vulnerable to noise interference because their operation is based on instantaneous peak or valley current sensing. Additionally, different control configurations must be employed for $M \lt 0.5$ and $M \gt 0.5$ , where M is the input-to-output voltage conversion ratio. In this paper, we propose a two independent single-loop voltage mode control method that can guarantee the flying capacitor voltage remains at half of the input voltage. The proposed control method is simple to implement and does not require current sensing or complex control algorithms, allowing the use of simple and low-cost digital or analog controllers. The method is also robust to noise interference because it only operates based on the output and flying capacitor voltage. Furthermore, this method ensures normal operation across all values of M without changing the control configuration. The experimental results from a 500 W-rated prototype confirmed the validity of the proposed control method.
引用
收藏
页码:151382 / 151394
页数:13
相关论文
共 50 条
  • [31] Two-parameter chaotic control in the voltage controlled buck converter
    Zhu, N
    Wu, WL
    PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1329 - 1333
  • [32] A Wide Conversion Ratio, 92.8% Efficiency, 3-Level Buck Converter with Adaptive On/Off-Time Control and Shared Charge Pump Intermediate Voltage Regulator
    Miyaji, Kousuke
    Karasawa, Yuki
    Fukuoka, Takanobu
    24TH ASIA AND SOUTH PACIFIC DESIGN AUTOMATION CONFERENCE (ASP-DAC 2019), 2019, : 1 - 1
  • [33] Sliding mode control of a high voltage DC-DC buck converter
    El Aroudi, A
    Robert, B
    Leyva, R
    Proceedings of the 2005 European Conference on Circuit Theory and Design, Vol 3, 2005, : 55 - 59
  • [34] Parabolic-Modulated Sliding-Mode Voltage Control of a Buck Converter
    Qi, Wenlong
    Li, Sinan
    Tan, Siew-Chong
    Hui, S. Y. R.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (01) : 844 - 854
  • [35] Stability Properties of the 3-Level Flying Capacitor Buck Converter Under Peak or Valley Current-Programmed-Control
    Abdelhamid, Eslam
    Bonanno, Giovanni
    Corradini, Luca
    Mattavelli, Paolo
    Agostinelli, Matteo
    2018 IEEE 19TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2018,
  • [36] Implementation and Design of Voltage-Mode PFM Control Buck Power Converter
    Lee, Min-Chin
    Jian, Ruey-Wun
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 2390 - 2394
  • [37] Nested Loop Control of a Buck Converter under Variable Input Voltage and Load Conditions
    Anuchin, Alecksey
    Shpak, Dmitry
    Ahmed, Md Rishad
    Stolyarov, Evgeniy
    Surnin, Dimid
    Acedo, Jaime Pando
    2020 55TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2020,
  • [38] Double-Loop Controller Design of a Single-Phase 3-Level Power Factor Correction Converter
    Han, Jun-Hyuk
    Kim, IL-Song
    ELECTRONICS, 2024, 13 (14)
  • [39] Modeling of 3-Level Buck Converters in Discontinuous Conduction Mode for Stand-by Mode Power Supply
    Yamauchi, Yoshitaka
    Sai, Toru
    Sakurai, Takayasu
    Takamiya, Makoto
    2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017,
  • [40] A Digital Predictive Critical Conduction Mode Buck Converter Control Method
    Lee, Jye-June
    Shin, Jong-Won
    Cho, Bo Hyung
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 709 - 714