Results of an intercomparison for electric field strength measurements within the German calibration service

被引:1
|
作者
Pape R. [1 ]
Karsten U. [2 ]
Lindner F.-M. [3 ]
Rittmann F. [4 ]
Von Freeden J. [5 ]
Kleine-Ostmann T. [1 ]
Schrader T. [1 ]
机构
[1] Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, Braunschweig
[2] TESEQ GmbH, Landsberger Str. 255, Berlin
[3] Kalibrierzentrum der Bundeswehr, Sielower Landstr. 66, Cottbus
[4] Steep GmbH, Lise-Meitner-Strasse 6, Ottobrunn
[5] Narda Safety Test Solutions GmbH, Sandwiesenstr. 7, Pfullingen
关键词
Electric fields - Probes - Electromagnetic waves;
D O I
10.5194/ars-15-243-2017
中图分类号
学科分类号
摘要
In this paper we discuss the results of an intercomparison for electric field strength measurements within the German Calibration Service (Deutscher Kalibrierdienst-DKD). The comparison has been carried out on the field strength value required to reach a display reading of 20Vm-1 of the field probes for frequencies between 100MHz and 18 GHz. Five laboratories joined the intercomparison including the Physikalisch-Technische Bundesanstalt (PTB), the German National Metrology Institute that keeps the primary standard for electric field strength. As measurement artefacts both a small 1-Axis probe usually used as transfer sensor at PTB and a larger 3-Axis commercial field probe have been used. While the results agree well for the small field probe and when the larger commercial 3-Axis field probe is oriented in the direction of the magnetic field, larger deviations occur, when the larger 3-Axis field probe is oriented into the direction of the Poynting vector of the calibration field. © Author(s) 2017.
引用
收藏
页码:243 / 248
页数:5
相关论文
共 50 条
  • [1] Results of an intercomparison for free space antenna factor measurements within the German Calibration Service (DKD)
    Kleine-Ostmann, Thomas
    Huncke, Frank
    Schwarzbeck, Dieter
    Martetschlaeger, Otto
    Gassner, Juergen
    Guserle, Andreas
    Roemer, Christian
    Hufnagel, Thomas
    Lehmann, Mario
    Karsten, Uwe
    Schrader, Thorsten
    ADVANCES IN RADIO SCIENCE, 2016, 14 (14) : 11 - 16
  • [2] Results from the national intercomparison for rise time and bandwidth measurements within the German Calibration Service (Deutscher Kalibrierdienst - DKD)
    Baaske, Kai
    Kleine-Ostmann, Thomas
    Schrader, Thorsten
    ADVANCES IN RADIO SCIENCE, 2019, 17 : 45 - 49
  • [3] Results of the national antenna intercomparison 2017/2018 within the German Calibration Service (Deutscher Kalibrierdienst - DKD)
    Ulm, David
    Kleine-Ostmann, Thomas
    Schrader, Thorsten
    ADVANCES IN RADIO SCIENCE, 2019, 17 : 35 - 44
  • [4] EFFECT OF TRANSDUCER SIZE AND CALIBRATION METHOD ON MEASUREMENTS OF ELECTRIC-FIELD STRENGTH
    ZAKHAROV, AG
    MEASUREMENT TECHNIQUES USSR, 1984, 27 (11): : 1042 - 1045
  • [5] INTERNATIONAL INTERCOMPARISON OF ELECTRIC-FIELD STRENGTH AT 100 MHZ
    STUBENRAUCH, CF
    GALLIANO, PG
    BABIJ, TM
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (01) : 235 - 237
  • [6] AIRCRAFT ELECTRIC-FIELD MEASUREMENTS - CALIBRATION AND AMBIENT FIELD RETRIEVAL
    KOSHAK, WJ
    BAILEY, J
    CHRISTIAN, HJ
    MACH, DM
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1994, 99 (D11) : 22781 - 22792
  • [7] Intercomparison of photoacoustic and cavity attenuated phase shift instruments: laboratory calibration and field measurements
    Zhang, Jialuo
    Chen, Jun
    Wang, Meng
    Su, Mingxu
    Zhou, Wu
    Varma, Ravi
    Lou, Shengrong
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2021, 10 (02) : 245 - 255
  • [8] DEVELOPMENT AND CALIBRATION OF ELECTRIC-FIELD STRENGTH MEASURING-INSTRUMENTS
    RICHTER, H
    BRAUN, A
    BRZOSTEK, E
    KIND, D
    PTB-MITTEILUNGEN, 1990, 100 (02): : 99 - 106
  • [9] PRELIMINARY RESULTS OF ELECTRIC FIELD MEASUREMENTS IN AURORAL ZONE
    FOPPL, H
    HAERENDEL, G
    HASER, L
    LUST, R
    MELZNER, F
    MEYER, B
    NEUSS, H
    RABBEN, HH
    RIEGER, E
    STOCKER, J
    JOURNAL OF GEOPHYSICAL RESEARCH, 1968, 73 (01): : 21 - +
  • [10] Electric field calibration in micro-electrode chambers by temperature measurements
    Glasser, H
    Schnelle, T
    Müller, T
    Fuhr, G
    THERMOCHIMICA ACTA, 1999, 333 (02) : 183 - 190