Potential and challenges in long-term monitoring of concrete carbonation using embedded-type optical sensors

被引:0
|
作者
Alemu, Abel Shiferaw [1 ]
Ko, Kwanyoung [2 ]
Jeong, Jena
Chung, Haegeun [3 ]
Ramezani, Hamidreza [4 ,5 ]
Kim, Hyeong-Ki [1 ]
机构
[1] Chosun Univ, Dept Architectural Engn, 309 Pilmun Daero, Gwangju 61452, South Korea
[2] Korea Res Inst Stand & Sci KRISS, Nanobio Measurement Grp, Daejeon 34113, South Korea
[3] Konkuk Univ, Dept Environm Engn, 120 Neungdong Ro, Seoul 05029, South Korea
[4] Univ Orleans, CNRS, UMR 7374, ICMN,Interfaces Confinement Mat & Nanostruct, 1b Rue Ferollerie,CS 40059, F-45071 Orleans, France
[5] Univ Orleans, Polytech Orleans, Interfaces Confinement Mat & Nanostruct, ICMN,CNRS,UMR 7374, 8 Rue Leonrad Vinci, F-45072 Orleans, France
基金
新加坡国家研究基金会;
关键词
Carbonation; Optical sensors; Concrete; Monitoring; Durability; PH; SERVICE LIFE PREDICTION; REINFORCEMENT CORROSION; MEMBRANE; DESIGN;
D O I
10.1016/j.cscm.2024.e03960
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study explores the long-term viability of embedded optical sensors designed for nondestructive monitoring of carbonation and pH levels in concrete structures. The sensors, featuring a reactor with a phenolphthalein solution and optical fibers, were embedded at various depths within mortar specimens and monitored over 250 days under different curing, drying, and carbonation conditions. Key challenges were identified, including the fragility of the dialysis membrane and optical fibers during concrete pouring, as well as the rapid drying of the detection solution, which compromised sensor longevity. Additionally, phenolphthalein's color change behavior at high pH levels (>12.5) posed a limitation. Proposed improvements include using a gel-based indicator to reduce drying, enhancing physical protection for the sensor components, and exploring alternative pH indicators like thymolphthalein. These modifications aim to enhance the sensor's durability and reliability for long-term monitoring of carbonation and pH in concrete.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Long-term durability of onshore coated concrete —chloride ion and carbonation effects
    Seyedhamed Sadati
    Mehdi K. Moradllo
    Mohammad Shekarchi
    Frontiers of Structural and Civil Engineering, 2016, 10 : 150 - 161
  • [32] Long-term In Vivo Monitoring of Chemicals with Fiber Sensors
    Wang, Jiajia
    Wang, Liyuan
    Feng, Jianyou
    Tang, Chengqiang
    Sun, Xuemei
    Peng, Huisheng
    ADVANCED FIBER MATERIALS, 2021, 3 (01) : 47 - 58
  • [33] Long-term In Vivo Monitoring of Chemicals with Fiber Sensors
    Jiajia Wang
    Liyuan Wang
    Jianyou Feng
    Chengqiang Tang
    Xuemei Sun
    Huisheng Peng
    Advanced Fiber Materials, 2021, 3 : 47 - 58
  • [34] Long-term durability of onshore coated concrete - chloride ion and carbonation effects
    Sadati, Seyedhamed
    Moradllo, Mehdi K.
    Shekarchi, Mohammad
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2016, 10 (02) : 150 - 161
  • [35] Damage and retrofitting monitoring in reinforced concrete structures along with long-term strength and fatigue monitoring using embedded Lead Zirconate Titanate patches
    Kaur, Naveet
    Bhalla, Suresh
    Maddu, Subhash C. G.
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2019, 30 (01) : 100 - 115
  • [36] Monitoring of Concrete Hydration Using Resin Jacketed Embedded PZT Sensors
    Chhabra, Rajat
    Negi, Prateek
    Kaur, Naveet
    Bhalla, Suresh
    APPLICATIONS OF GEOMATICS IN CIVIL ENGINEERING, 2020, 33 : 83 - 91
  • [37] Long-term monitoring of reinforcement corrosion in concrete using ground penetrating radar
    Hong, Shuxian
    Wiggenhauser, Herbert
    Helmerich, Rosemarie
    Dong, Biqin
    Dong, Peng
    Xing, Feng
    CORROSION SCIENCE, 2017, 114 : 123 - 132
  • [38] LONG-TERM MONITORING OF HYDRATION AND CONCRETE CURING USING METHODS OF IMPEDANCE SPECTROSCOPY
    Kusak, Ivo
    Lunak, Miroslav
    Pazdera, Lubos
    Topolar, Libor
    Bilek, Vlastimil
    NDE FOR SAFETY: DEFEKTOSKOPIE 2010, 2010, : 149 - 156
  • [39] LONG-TERM MONITORING OF CONCRETE SETTING BY USING TWO ELECTRODES IMPEDANCE SPECTROSCOPY
    Lunak, Miroslav
    Kusak, Ivo
    Pazdera, Lubos
    Topolar, Libor
    Bilek, Vlastimil
    NDE FOR SAFETY: DEFEKTOSKOPIE 2010, 2010, : 157 - 160
  • [40] Long-term monitoring of composite girders using optical fiber sensor
    Oshima, Y.
    Kado, M.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 777 - 781