Removal of iron, manganese and high ammonia from groundwater by biofilter

被引:0
|
作者
Cai, Yan-An [1 ]
Li, Dong [1 ]
Zeng, Hui-Ping [1 ]
Luo, Ya-Hong [1 ]
Zhang, Jie [1 ,2 ]
机构
[1] Key Laboratory of Beijing Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing,100124, China
[2] State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin,150090, China
关键词
Aeration intensity - Ammonia concentrations - Biological aerated filter - Biological filters - Manganese concentration - Oxidation process - Processing capacities - Upflow filtration;
D O I
暂无
中图分类号
学科分类号
摘要
A pilot-scale biological filter was constructed to removal of iron, manganese and high ammonia simultaneously from groundwater. The results indicated that the failure of manganese and ammonia oxidation when the influent ammonia concentration was above 2.0 mg/L without extra aeration. Oxidation of iron, manganese and ammonia could be completed by downflow filtration with the aeration at the bottom of the filter bed, while the processing capacity was affected significantly and was not suitable for application of the biofilter. The upflow filtration with the same aeration mode could also met the oxygen demands of the oxidation process, however, the oxidized iron and manganese were easily taken out filter bed, causing high iron and manganese concentration in the effluent. For the upflow filtration with extra aeration at the bottom of the filter bed, the experiments demonstrated that the intercepting capacity of filter was damaged significantly by disturbance of aeration compared to the case of upflow filtration without aeration and was inversely correlatedwith the aeration intensity.
引用
收藏
页码:1993 / 1997
相关论文
共 50 条
  • [41] Iron and manganese removal from groundwater using limestone filter with iron-oxidized bacteria
    H. A. Aziz
    H. A. Tajarudin
    T. H. L. Wei
    M. Y. D. Alazaiza
    [J]. International Journal of Environmental Science and Technology, 2020, 17 : 2667 - 2680
  • [42] Influence of Sequential Aeration and Ozonation on Effectiveness of Iron and Manganese Removal from Groundwater
    Olsinska, Urszula
    Bragiel, Tomasz
    [J]. OCHRONA SRODOWISKA, 2015, 37 (03): : 25 - 28
  • [43] Experimental research of physical-biological removal of iron and manganese from groundwater
    Mazeikiene, A
    [J]. 6Th International Conference Environmental Engineering, Vols 1 and 2, 2005, : 399 - 404
  • [44] Removal of iron and manganese from groundwater sources using nano-biosorbents
    Mohammad Akbari Zadeh
    Allahyar Daghbandan
    Behrouz Abbasi Souraki
    [J]. Chemical and Biological Technologies in Agriculture, 9
  • [45] Performance of membrane filtration in the removal of iron and manganese from Malaysia's groundwater
    Kasim, Norherdawati
    Mohammad, Abdul Wahab
    Abdullah, Siti Rozaimah Sheikh
    [J]. MEMBRANE AND WATER TREATMENT, 2016, 7 (04): : 277 - 296
  • [46] Iron and manganese removal from groundwater using limestone filter with iron-oxidized bacteria
    Aziz, H. A.
    Tajarudin, H. A.
    Wei, T. H. L.
    Alazaiza, M. Y. D.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2020, 17 (05) : 2667 - 2680
  • [47] Use of iron- and manganese-oxidizing bacteria for the combined removal of iron, manganese and arsenic from contaminated groundwater
    Katsoylannis, Ioannis A.
    Zouboulis, Anastasios I.
    [J]. WATER QUALITY RESEARCH JOURNAL OF CANADA, 2006, 41 (02): : 117 - 129
  • [48] Removal of a high load of ammonia by a marine bacterium, Vibrio alginolyticus in biofilter
    Kim N.J.
    Shoda M.
    [J]. Biotechnology and Bioprocess Engineering, 2002, 7 (5) : 316 - 322
  • [49] Microbial community response reveals underlying mechanism of industrial-scale manganese sand biofilters used for the simultaneous removal of iron, manganese and ammonia from groundwater
    Zhang, Yu
    Sun, Rui
    Zhou, Aijuan
    Zhang, Jiaguang
    Luan, Yunbo
    Jia, Jianna
    Yue, Xiuping
    Zhang, Jie
    [J]. AMB EXPRESS, 2018, 8
  • [50] REMOVING IRON AND MANGANESE FROM GROUNDWATER
    不详
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1984, 76 (11): : 67 - &