A distance protection scheme not affected by transient characteristic of capacitor voltage transformer for HV long transmission line

被引:0
|
作者
机构
[1] Jiao, Zaibin
[2] Qi, Qian
[3] Yang, Liming
[4] Wang, Youyin
[5] Ning, Rong
来源
Jiao, Zaibin | 1600年 / Power System Technology Press卷 / 38期
关键词
Electric power transmission - Power transformers - Surge protection - Electric power transmission networks - Extraction - Variable speed transmissions - Transformer protection - Electric fault currents - Power quality - Electric power system protection;
D O I
10.13335/j.1000-3673.pst.2014.11.036
中图分类号
学科分类号
摘要
Affected by transient characteristic of capacitor voltage transformer (CVT), the distance protection for HV transmission line is easily to mal-operate due to transient overreach, thus the secure and stable operation of power grid is affected. A new distance protection scheme that is not affected by the transient characteristics of CVT is proposed and its principle is as following: firstly, on the basis that the CVT can transmit and transform power frequency phasor, by means of the matrix pencil based accurate power frequency phasor extraction method the power frequency phasors of voltage and current at the position where the protection is installed are calculated; secondly, the voltage and current at the position of the long distance transmission line, where the protection is set, are calculated by Bergeron model; finally, coordinating with directional element and taking the setting point as the observation point, the fault point is located by traditional distance protection algorithm. The proposed principle is not affected by transient characteristic of CVT and the impacts of distributed parameters of the long distance transmission line are taken into account, thus the proposed distance protection scheme possesses a better performance, and the effectiveness of the proposed algorithm is validated by simulation results. ©, 2014, Power System Technology Press. All right reserved.
引用
收藏
相关论文
共 50 条
  • [21] Single-ended protection method for hybrid HVDC transmission line based on transient voltage characteristic frequency band
    Shu, Hongchun
    Wang, Shixin
    Lei, Shunguang
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
  • [22] An Incremental Quantity Based Distance Protection With Capacitor Voltage Estimation for Series Compensated Transmission Lines
    Hoq, Md Tanbhir
    Wang, Jianping
    Taylor, Nathaniel
    IEEE ACCESS, 2021, 9 : 164493 - 164502
  • [23] An Incremental Quantity Based Distance Protection with Capacitor Voltage Estimation for Series Compensated Transmission Lines
    Hoq, Md. Tanbhir
    Wang, Jianping
    Taylor, Nathaniel
    IEEE Access, 2021, 9 : 164493 - 164502
  • [24] Influence of capacitive current on distance protection of UHV long transmission line
    School of Electrical and Automation Engineering, Tianjin University, Tianjin 300072, China
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2006, SUPPL. (83-87):
  • [25] Voltage Actuated Transmission Line Protection Scheme Applying Signal Processing Techniques
    Chouhan, Dharmendra
    Bhaskar, M. K.
    Mahela, Om Prakash
    2022 SECOND INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL, COMPUTING, COMMUNICATION AND SUSTAINABLE TECHNOLOGIES (ICAECT), 2022,
  • [26] Extra high speed hybrid protection scheme for high voltage transmission line
    Zou, G. B.
    Gao, H. L.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 63 : 83 - 90
  • [27] Thunderstruck transient process of UHVDC transmission line and response characteristic of traveling wave protection
    Li, Shuyong
    Guo, Qi
    Cui, Liu
    Cai, Zexiang
    Liang, Yi
    Dianwang Jishu/Power System Technology, 2015, 39 (10): : 2830 - 2835
  • [28] Performance assessment of distance protection fed by capacitor voltage transformer with electronic ferro-resonance suppression circuit
    Venkatesh, C.
    Swarup, K. Shanti
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 112 : 12 - 19
  • [29] A Protection Scheme for Series Capacitor Compensated Transmission Lines that Uses DC Component of Line Current
    Razavi, Abbas Ali
    Samet, Haidar
    2013 21ST IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2013,
  • [30] Distance protection scheme with travelling wave for UHVDC transmission line based on wavelet transform
    long, Chen Shi
    Chun, Shu Hong
    zhi, Wang Yong
    Fang, Zeng
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2162 - 2165