Bioelectrical Impedance and Muscle Thickness during Resistance Exercise of Upper Arm

被引:0
|
作者
Ishida M. [1 ]
Hamasaki T. [2 ]
Katsuno T. [1 ]
机构
[1] Road Environment Sensing System Research-Domain, Toyota Central R and D Labs. Inc
[2] Human Science Research-Domain, Toyota Central R and D Labs. Inc
关键词
arm curl exercise; bioelectrical impedance analysis; muscle fatigue; ultrasonic B-mode imaging;
D O I
10.11239/jsmbe.62.1
中图分类号
学科分类号
摘要
Muscle tissue swelling occurs immediately after exercise. Conventionally, this phenomenon has been evaluated by diagnostic imaging methods such as ultrasonic B-mode imaging. On the other hand, bioelectrical impedance analysis (BIA) is a simpler method to measure this phenomenon. In the BIA, changes in water volume inside and outside ofmuscle cells during exercise can be evaluated as changes in bioelectrical impedance (BI). In this study, the local muscle fatigue was effectively measured using BIA by concentrating the current in a narrow area and the results were compared with muscle thickness measured by ultrasonic B-mode imaging. The measurement site was the upper arm, and the exercise condition was four sets of arm curl exercise. Measurements ofupper arms were taken before exercise (base line: BL) and after each exercise set (post exercise: PE1-4). BI was converted into external cell water resistance (RECW), internal cell water resistance (RICW), and their parallel resistance (RICW//RECW). The results showed that RECW increased before PE1 and decreased after PE1. Therefore, exercise hyperemia was inferred to be a factor in muscle swelling after PE1. Then, the correlations between RECW, RICW, RICW//RECW and muscle thickness were calculated. Subsequently, a significant correlation was obtained between RICW//RECW and muscle thickness, especially after PE1. © 2024, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
页码:1 / 6
页数:5
相关论文
共 50 条
  • [21] CHANGES IN BIOELECTRICAL IMPEDANCE DURING FASTING
    GRAY, DS
    CLINICAL RESEARCH, 1988, 36 (03): : A760 - A760
  • [22] Passive dehydration reduces muscle thickness after resistance exercise
    Appell, Casey R.
    Jiwan, Nigel C.
    Sekiguchi, Yasuki
    Luk, Hui-Ying
    JOURNAL OF SPORTS SCIENCES, 2025, 43 (04) : 336 - 347
  • [23] IMPEDANCE IMAGING IN UPPER ARM FRACTURES
    KULKARNI, V
    HUTCHISON, JMS
    RITCHIE, IK
    MALLARD, JR
    JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (03): : 219 - 227
  • [24] Instructional Cueing Alters Upper Limb Muscle Activity and Kinematics During Elastic Resistance Exercise
    Reece, Ashley A.
    Parkinson, James E.
    Cudlip, Alan C.
    Page, Phil
    Holmes, Michael W. R.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2021, 100 (12) : 1176 - 1183
  • [25] Upper Extremity And Core Muscle Activation During An Aquatic Resistance Exercise Performed At Different Depths
    Borreani, Sebastien
    Carlos Colado, Juan
    Furio, Josep
    Martin, Fernando
    Benavent, Juan
    Madera, Joaquin
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 455 - 455
  • [26] Validity of estimating limb muscle volume by bioelectrical impedance
    Miyatani, M
    Kanehisa, H
    Masuo, Y
    Ito, M
    Fukunaga, T
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (01) : 386 - 394
  • [27] Estimation of segmental muscle volume by bioelectrical impedance spectroscopy
    Bartok, C
    Schoeller, DA
    JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) : 161 - 166
  • [28] Estimation of skeletal muscle mass by bioelectrical impedance analysis
    Janssen, I
    Heymsfield, SB
    Baumgartner, RN
    Ross, R
    JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (02) : 465 - 471
  • [29] Use of bioelectrical impedance analysis for monitoring fluid shift during maximal aerobic exercise.
    Collodel, L
    Favretto, G
    Teodori, T
    Caenaro, G
    Mordacchini, M
    Stritoni, P
    Nieri, A
    Piccoli, A
    MEDICINA DELLO SPORT, 1997, 50 (02) : 197 - 202
  • [30] DETERMINATION OF UPPER ARM MUSCLE AND FAT AREAS USING ELECTRICAL-IMPEDANCE MEASUREMENTS
    BROWN, BH
    KARATZAS, T
    NAKIELNY, R
    CLARKE, RG