Fault-tolerant Control of Fifteen-phase Induction Machine Under Asymmetrical Fault Condition

被引:0
|
作者
Zheng X. [1 ]
Ma W. [2 ]
Wang D. [2 ]
Yi X. [2 ]
Liu H. [2 ]
机构
[1] College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, 430074, Hubei Province
[2] National Key Laboratory of Science and Technology on Vessel Integrated Power System, Naval University of Engineering, Wuhan, 430033, Hubei Province
来源
Wang, Dong (wangdongl@sina.vip.com) | 2018年 / Chinese Society for Electrical Engineering卷 / 38期
基金
中国国家自然科学基金;
关键词
Asymmetrical fault condition; Fifteen-phase induction machine; Maximum torque; Tolerant-fault control;
D O I
10.13334/j.0258-8013.pcsee.170331
中图分类号
学科分类号
摘要
The superior fault-tolerant capability is one of the most significant advantages of the multi-phase induction machines. The post-fault currents with the maximum torque were optimized of a fifteen-phase induction machine under asymmetrical fault condition. The corresponding fault-tolerant control strategy was proposed. The fault-tolerant control was based on the normal decoupling transformation and machine mathematical model, thus the machine parameters need not be recalculated and the reconfiguration of the controller was minimized. Different open-circuited faults of a 45kW prototype 15-phase induction machine were analyzed and tested. The good agreement between calculated and experimental results verifies the accuracy of the proposed fault-tolerant control. © 2018 Chin. Soc. for Elec. Eng.
引用
收藏
页码:1212 / 1221
页数:9
相关论文
共 22 条
  • [11] Zhao P., Yang G., Li Y., Fault-tolerant control strategy for five-phase permanent magnetic synchronous motor under single phase open-circuit fault condition, Proceedings of the CSEE, 31, 24, pp. 68-76, (2011)
  • [12] Arashloo R.S., Martinez J.L.R., Salehifar M., Et al., Genetic algorithm-based output power optimization of fault tolerant fivephase brushless direct current drives applicable for electrical and hybrid electrical vehicles, IET Electric Power Applications, 8, 7, pp. 267-277, (2014)
  • [13] Abdel-Khalik A.S., Masoud M.I., Ahmed S., Et al., Calculation of derating factors based on steady-state unbalanced multiphase induction machine model under open phase(s) and optimal winding currents, Electric Power Systems Research, 106, 1, pp. 214-225, (2014)
  • [14] Abdel-Khalik A.S., Ahmed S., Elserougi A.A., Et al., Effect of stator winding connection of five-phase induction machines on torque ripples under open line condition, IEEE/ASME Trans. on Mechatronics, 20, 2, pp. 580-593, (2015)
  • [15] Dwari S., Parsa L., Fault-tolerant control of five-phase permanentmagnet motors with trapezoidal back EMF, IEEE Trans. on Industrial Electronics, 58, 2, pp. 476-485, (2011)
  • [16] Che H.S., Duran M.J., Levi E., Et al., Postfault operation of an asymmetrical six-phase induction machine with single and two isolated neutral points, IEEE Trans. on Power Electronics, 29, 10, pp. 5406-5416, (2014)
  • [17] Bianchi N., Fornasiero E., Bolognani S., Thermal analysis of a fivephase motor under faulty operations, IEEE Trans. on Industry Applications, 49, 4, pp. 1531-1538, (2013)
  • [18] Sun Z., Wang J., Jewell G.W., Et al., Enhanced optimal torque control of fault-tolerant PM machine under flux-weakening operation, IEEE Transactions on Industrial Electronics, 57, 1, pp. 344-353, (2010)
  • [19] Mohammadpour A., Parsa L., Global fault-tolerant control technique for multi-phase permanent-magnet machines, IEEE Trans. on Industry Applications, 51, 1, pp. 178-186, (2015)
  • [20] Sadeghi S., Guo L., Toliyat H.A., Et al., Wide operational speed range of five-phase permanent magnet machines by using different stator winding configurations, IEEE Transactions on Industrial Electronics, 59, 6, pp. 2621-2631, (2012)