Shaking table tests for structures with viscous dampers considering SSI effect

被引:0
|
作者
Zhao, Xuefei [1 ]
Wang, Shuguang [1 ]
Wang, Hai [1 ]
Du, Dongsheng [1 ]
Liu, Weiqing [1 ]
机构
[1] College of Civil Engineering, Nanjing Tech University, Nanjing,211816, China
来源
关键词
402 Buildings and Towers - 405.2 Construction Methods - 408 Structural Design - 408.2 Structural Members and Shapes - 483.1 Soils and Soil Mechanics - 483.2 Foundations - 484.2 Secondary Earthquake Effects - 545.3 Steel - 631.1 Fluid Flow; General; -; 931.1; Mechanics;
D O I
暂无
中图分类号
学科分类号
摘要
10
引用
收藏
页码:146 / 154
相关论文
共 50 条
  • [41] Prediction method for seismic responses of underground structures in shaking table tests
    Jiang, Zhi-Wei
    Liu, Jing-Bo
    Xu, Cheng-Shun
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2021, 43 (07): : 1220 - 1227
  • [42] Shaking table tests on seismic retrofitting of rammed-earth structures
    Wang, Yaan
    Wang, Ming
    Liu, Kai
    Pan, Wen
    Yang, Xiaodong
    BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (03) : 1037 - 1055
  • [43] Shaking table experimentation on adjacent structures controlled by passive and semi-active MR dampers
    Basili, M.
    De Angelis, M.
    Fraraccio, G.
    JOURNAL OF SOUND AND VIBRATION, 2013, 332 (13) : 3113 - 3133
  • [44] Evaluation of dynamic pile group effect by shaking table tests
    Kim, SR
    Kim, MM
    Chung, CK
    Kim, SH
    PROCEEDINGS OF THE FIFTEENTH INTERNATIONAL CONFERENCE ON SOIL MECHANICS AND GEOTECHNICAL ENGINEERING VOLS 1-3, 2001, : 935 - 938
  • [45] Shaking table tests and numerical investigations of a novel response-based adaptive control strategy for multi-story structures with magnetorheological dampers
    Wani, Zubair Rashid
    Tantray, Manzoor
    Farsangi, Ehsan Noroozinejad
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [46] Shaking table test study on mid-story isolation structures with viscous damper
    Jin, Jianmin
    Tan, Ping
    Zhou, Fulin
    Huang, Xiangyun
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 1149 - 1152
  • [47] Effect of PGV/PGA ratio on seismic-induced vibrations of structures equipped with parallel tuned mass dampers considering SSI
    Araz, Onur
    STRUCTURES, 2024, 68
  • [48] Shaking Table Tests of Underground Substation Considering Soil-Structure-Equipment Interaction
    Wang, Zhihao
    Lv, Jing
    Pai, Guanglin
    Zhang, Wei
    Jiao, Longfei
    Liu, Peng
    Wen, Bo
    Kang, Yongkang
    Zhang, Fan
    Xu, Peng
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2025, 34 (01):
  • [49] Shaking table tests of a switching power cabinet considering physical damage and functionality loss
    Zuo, Haopeng
    Sun, Guoliang
    Zhang, Pengbo
    Wang, Meiling
    Li, Jichao
    Shang, Qingxue
    Wang, Tao
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 177
  • [50] Shaking table tests on seismic response of rocking frame structure considering foundation uplift
    Wang G.-B.
    Wang Y.
    Yu H.-T.
    Zheng N.-W.
    Sun F.-X.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2021, 43 (11): : 2064 - 2074