A gas chromatography method established for oxygen transfer efficiency measurement

被引:0
|
作者
MU, Jun [1 ]
ZHANG, Feijuan [2 ]
ZHU, Xiuhua [1 ]
DONG, Xuewei [1 ]
机构
[1] School of Environmental and Chemical Engineering, Dalian Jiaotong University, Dalian, 116028, China
[2] School of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
来源
Journal of Environmental Sciences | 2009年 / 21卷 / SUPPL. 1期
关键词
Carbon dioxide - Efficiency - Water aeration - Oxygen - Effluent treatment - Nitrogen - Effluents - Wastewater treatment;
D O I
10.1016/S1001-0742(09)60060-7
中图分类号
学科分类号
摘要
A new method of oxygen transfer efficiency (OTE) measurement for aerobic biochemical wastewater treatment system was introduced. The effluent gas and the influent air around the fan were collected and analyzed with a gas chromatograph. The ratios of the concentration of nitrogen to that of oxygen for both influent and effluent gases were determined. The reduced percentage of the ratio for the influent gases was taken as oxygen transfer efficiency (OTE). The nitrogen gas was used as an inner mark. Using this method, the OTE measurement was not affected by the temperature, water vapor mixture and carbon dioxide produced within the treatment system. The accuracy of the method was analyzed. The standard deviation of the ratios for influent and effluent gases were 0.0006 and 0.0008, respectively. The OTE values of a full-scale aeration tank were detected using this method. The OTE values of the representative spots in the aeration tank varied from 7.3% to 11.5%. © 2009 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences.
引用
收藏
相关论文
共 50 条