Wear of alumina on alumina total hip prosthesis - effect of lubricant on hip simulator test

被引:0
|
作者
Ueno, M. [1 ]
Amino, H. [1 ]
Oonishi, H. [2 ]
Clarke, I.C. [2 ]
Good, V. [2 ]
机构
[1] Bioceram Division, Kyocera Corporation, 6 Takeda Tobadono-Cho, Fushimi-Ku, Kyoto 612-8501, Japan
[2] Dept. of Orthopaedic Surgery, Artif. Jt. Sect. Biomat. Res. Lab., Osaka Minami National Hospital, Osaka, Japan
关键词
Ceramic materials - Computational methods - Hip prostheses - Lubricants - Materials testing - Micrometers - Solutions - Wear of materials;
D O I
暂无
中图分类号
学科分类号
摘要
The complex wear-friction-lubrication behavior of alumina on alumina combination in total hip prostheses (THP) was investigated using a hip joint simulator. The objectives of this study were to evaluate the effect of the ball/cup clearance and of the lubricant conditions. Alumina bearings were categorized in three diametrical clearances, 20-30,60-70 and 90-100 micrometer, three each and wear tests were carried out with 90% bovine serum. There was no significant difference between three groups. Volumetric wear in the run-in phase for all tested nine ceramic liners averaged 0.27mm3/million cycles and in the steady-state phase averaged 0.0042mm3/million cycles. In addition to the 90% serum, 27% serum and saline were used as the lubricant for evaluate the effect of serum concentration on alumina on alumina wear couples. The wear test results showed that in all tested conditions the wear trends of alumina BEARING were bi-phasic and wear volume could be affected by the serum concentration. Both 'Run-in' and 'Steady-state' wear rates in 90% bovine serum were three times higher than those in saline.
引用
收藏
页码:561 / 564
相关论文
共 50 条
  • [1] Wear of alumina on alumina total hip prosthesis - Effect of lubricant on hip simulator test
    Ueno, M
    Amino, H
    Oonishi, H
    Clarke, IC
    Good, V
    BIOCERAMICS, 2000, 192-1 : 561 - 564
  • [2] Wear of alumina-on-alumina total hip prosthesis: Effect of diametrical clearance and lubricant on hip simulator test
    Oonishi, H
    Clarke, IC
    Good, V
    Ueno, M
    Amino, H
    ARTHROPLASTY 2000: RECENT ADVANCES IN TOTAL JOINT REPLACEMENT, 2001, : 35 - 39
  • [3] Low wear and friction in alumina/alumina total hip joints - A hip simulator study
    Saikko, V
    Pfaff, HG
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05): : 443 - 448
  • [4] The influence of implant position on the wear of alumina-on-alumina studied in a hip simulator
    Affatato, S
    Bersaglia, G
    Foltran, I
    Emiliani, D
    Traina, F
    Toni, A
    WEAR, 2004, 256 (3-4) : 400 - 405
  • [5] An in vitro wear study of alumina-alumina total hip prostheses
    Smith, SL
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H5) : 443 - 446
  • [6] Engineering aspect of alumina on alumina hip prosthesis
    Sedel, L.
    Raould, A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H1) : 21 - 27
  • [7] Investigation of the wear properties of ceramic total hip prostheses made of alumina and zirconia combination: A hip simulator study
    Ueno, M
    Ikeuchi, K
    BIOCERAMICS 15, 2003, 240-2 : 809 - 812
  • [8] Characterisation of the wear mechanisms in retrieved alumina-on-alumina total hip replacements
    Zeng, P.
    Rainforth, W. M.
    Stewart, T. D.
    WEAR, 2017, 376 : 212 - 222
  • [9] The friction and lubrication of alumina-on-alumina total hip prostheses - The effect of radial clearance and wear testing
    Scholes, SC
    Green, SM
    Unsworth, A
    BIOCERAMICS 14, 2002, 218-2 : 535 - 539
  • [10] Lubrication and wear of alumina-alumina hip bearings
    Cheng, NY
    Medley, JB
    Bobyn, JD
    Krygier, JJ
    BOUNDARY AND MIXED LUBRICATION: SCIENCE AND APPLICATIONS, 2002, 40 : 387 - 397