Characterisation of the wear mechanisms in retrieved alumina-on-alumina total hip replacements

被引:8
|
作者
Zeng, P. [1 ]
Rainforth, W. M. [1 ]
Stewart, T. D. [2 ]
机构
[1] Univ Sheffield, Dept Mat Sci & Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
Alumina; High resolution transmission electron microscopy; Focused ion beam; Total hip replacement; BEARING SURFACE; SLIDING WEAR; ARTHROPLASTY; PROSTHESES; CERAMICS; IMPLANTS; MICROSEPARATION; ASSOCIATION; MICROSCOPY; OSTEOLYSIS;
D O I
10.1016/j.wear.2016.11.045
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Due to their superior wear performance and biocompatibility compared to alternative polymer/metal prostheses, alumina-on-alumina total hip replacements (THRs) are extensively used for young and more active patients. However, the understanding of the wear mechanisms of alumina in vivo remains relatively poor, and there remains little quantitative understanding of the structural and chemical changes at the articulating surface. In the current study, the surface and sub-surface microstructures of retrieved in vivo alumina THRs are presented. Severe wear, also called stripe wear, was observed in all cases. The transition between the stripe wear and the mild wear was very sharp. Site-specific cross-section TEM specimens were prepared by Focused Ion Beam (FIB) at the stripe boundary region. The results suggest predominantly intergranular fracture occurred that was restricted to the outer layer of grains below the surface, with transgranular fracture also occurring in the stripe wear region. Cracking was believed to be initiated by extensive dislocation slip. A thin layer of hydroxide was also observed at the extreme surface of the mild wear region by aberration-corrected high resolution transmission electron microscopy (HRTEM). The wear mechanisms are discussed. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:212 / 222
页数:11
相关论文
共 50 条
  • [1] Alumina-on-alumina hip implants A WEAR STUDY OF RETRIEVED COMPONENTS
    Affatato, S.
    Traina, F.
    De Fine, M.
    Carmignato, S.
    Toni, A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (01): : 37 - 42
  • [2] Wear in alumina-on-alumina ceramic total hip replacements A RETRIEVAL ANALYSIS OF EDGE LOADING
    Esposito, C. I.
    Walter, W. L.
    Roques, A.
    Tuke, M. A.
    Zicat, B. A.
    Walsh, W. R.
    Walter, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07): : 901 - 907
  • [3] Wear debris from two different alumina-on-alumina total hip arthroplasties
    Böhler, M
    Mochida, Y
    Bauer, TW
    Plenk, H
    Salzer, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06): : 901 - 909
  • [4] Microseparation and stripe wear in alumina-on-alumina hip implants
    Affatato, Saverio
    Traina, Francesco
    Toni, Aldo
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (06): : 506 - 512
  • [5] Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup
    Prudhommeaux, F
    Hamadouche, M
    Nevelos, J
    Doyle, C
    Meunier, A
    Sedel, L
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (379) : 113 - 122
  • [6] Wear of alumina-on-alumina total hip prosthesis: Effect of diametrical clearance and lubricant on hip simulator test
    Oonishi, H
    Clarke, IC
    Good, V
    Ueno, M
    Amino, H
    [J]. ARTHROPLASTY 2000: RECENT ADVANCES IN TOTAL JOINT REPLACEMENT, 2001, : 35 - 39
  • [7] Severe wear from retrieved alumina-on-alumina coupled implant: a case report
    Affatato, S
    Sudanese, A
    Brizio, L
    Squarzoni, S
    Toni, A
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2001, 24 (09): : 655 - 662
  • [8] The friction and lubrication of alumina-on-alumina total hip prostheses - The effect of radial clearance and wear testing
    Scholes, SC
    Green, SM
    Unsworth, A
    [J]. BIOCERAMICS 14, 2002, 218-2 : 535 - 539
  • [9] Use of an alumina-on-alumina bearing system in total hip arthroplasty for osteonecrosis of the hip
    Seyler, Thorsten M.
    Bonutti, Peter M.
    Shen, Jianhua
    Naughton, Marybeth
    Kester, Mark
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 116 - 125
  • [10] The influence of implant position on the wear of alumina-on-alumina studied in a hip simulator
    Affatato, S
    Bersaglia, G
    Foltran, I
    Emiliani, D
    Traina, F
    Toni, A
    [J]. WEAR, 2004, 256 (3-4) : 400 - 405