Application of Attenuated Total Reflectance Fourier-Transform Infrared Spectroscopy in Human Sera: Validate the method for contributing effective strategy for the storage and preservation

被引:0
|
作者
Jaimanee, Juthamas [1 ]
Chatchawal, Patutong [2 ]
Wongwattanakul, Molin [2 ,3 ]
Phantanawiboon, Supranee [4 ]
Leelayuwat, Chanvit [3 ,5 ]
Jumnainsong, Amonrat [3 ,5 ]
机构
[1] Khon Kaen Univ, Med Technol Program, Fac Associated Med Sci, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Fac Associated Med Sci, Ctr Innovat & Stand Med Technol & Phys Therapy, Khon Kaen 40002, Thailand
[3] Khon Kaen Univ, Fac Associated Med Sci, Sch Med Technol, Khon Kaen 40002, Thailand
[4] Khon Kaen Univ, Fac Med, Dept Microbiol, Khon Kaen 40002, Thailand
[5] Khon Kaen Univ, Fac Associated Med Sci, Ctr Res & Dev Med Diagnost Labs CMDL, Khon Kaen 40002, Thailand
关键词
Serum stabilization; Storage condition; Characteristic spectra; Lipid instability; SECONDARY STRUCTURE; IR SPECTROSCOPY; FLUIDS; TIME;
D O I
10.1016/j.vibspec.2024.103741
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The serum is one of the biological specimens that have been extensively studied as biomarkers and is recognized as an effective tool for screening and diagnosing a variety of diseases. Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR) is a practical technique utilized in investigating characteristic spectra in infectious diseases cancer, and metabolic status. However, the pre-analytical procedure as storage condition is a crucial phase that directly impacts the accuracy of the result. In this study, we intend to investigate the effects of serum stabilization under both identical and distinct storage conditions on the FTIR spectral patterns, intensity variations, and macromolecule composition. The ten serum samples were stored in 3 different conditions including 4 degrees C,-20 degrees C, degrees C, and-80 degrees C degrees C for six different time intervals (7, 14, 21, 28, 56, and 84 days). The spectra were obtained by ATR-FTIR spectroscopy. The serum stabilization was studied in two investigations: one focusing on the stability of serum under identical conditions over six different time intervals, and the other examining the stability of serum stored under three distinct conditions. Principal Component Analysis (PCA) and Area Under the Peak (AUP) were used to investigate clusters in different sets of data across five spectral ranges. The macromolecule composition was identified in conjunction with the intensity measurements. The results showed that the same conditions remained stable across six different time intervals, as indicated by the consistent PCA results. In contrast, the stabilization of serum under different temperature condition showed different major intensities across the five selected positive bands, including 1781 cm-- 1 , 1740 cm-1 1727 cm-- 1 corresponding to lipid region (1800-1700 cm-1 ), and Amide region (1700-1500 cm- 1 ) at 1646 cm-- 1 , and 1632 cm-1 , when the serum was stored over 28 days. This might involve lipid peroxidation-induced changes in the secondary structure of proteins. Our findings indicated that serum should be stored at-80 degrees C degrees C to ensure stabilization and achieve the highest intensity. Additionally, preserving serum under consistent conditions was crucial to minimize variability and prevent external factors from affecting the results.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Application of attenuated total reflectance Fourier transform infrared spectroscopy in the mineralogical study of a landslide area, Hungary
    Udvardi, Beatrix
    Kovacs, Istvan Janos
    Konya, Peter
    Foldvari, Maria
    Furi, Judit
    Budai, Ferenc
    Falus, Gyorgy
    Fancsik, Tamas
    Szabo, Csaba
    Szalai, Zoltan
    Mihaly, Judith
    SEDIMENTARY GEOLOGY, 2014, 313 : 1 - 14
  • [22] Preliminary Method for Direct Quantification of Colistin Methanesulfonate by Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy
    Niece, Krista L.
    Akers, Kevin S.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2015, 59 (09) : 5542 - 5547
  • [23] Application and progress of Fourier transform attenuated total reflection infrared spectroscopy
    Xu, L
    Wang, NY
    Ba, SH
    Wang, YL
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (03) : 317 - 319
  • [24] An attenuated total reflectance cell for analysis of small molecule diffusion in polymer thin films with Fourier-transform infrared spectroscopy
    Balik, CM
    Simendinger, WH
    POLYMER, 1998, 39 (20) : 4723 - 4728
  • [25] Study of prepolymer stability using attenuated total reflectance Fourier transform infrared spectroscopy
    Strohecker, Sarah A.
    Kneas, Kristi A.
    Obetz, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [26] Forensic Classification of Pigments by Attenuated Total Reflectance - Fourier Transform Infrared Spectroscopy and Chemometrics
    Wei, Chenjie
    Wang, Jifen
    Ji, Jiahua
    ANALYTICAL LETTERS, 2021, 54 (08) : 1309 - 1328
  • [27] REAL-TIME ATTENUATED TOTAL REFLECTANCE FOURIER-TRANSFORM INFRARED-SPECTROSCOPY TO MONITOR MULTIACRYLATE POLYMERIZATION REACTIONS
    DIETZ, JE
    ELLIOTT, BJ
    PEPPAS, NA
    MACROMOLECULES, 1995, 28 (15) : 5163 - 5166
  • [28] Discrimination of clinically relevant Candida species by Fourier-transform infrared spectroscopy with attenuated total reflectance (FTIR-ATR)
    Silva, Sonia
    Tobaldini-Valerio, Flavia
    Costa-de-Oliveira, Sofia
    Henriques, Mariana
    Azeredo, Joana
    Ferreira, Eugenio C.
    Lopes, Joao A.
    Sousa, Clara
    RSC ADVANCES, 2016, 6 (94) : 92065 - 92072
  • [29] Attenuated total reflectance Fourier-transform infrared spectroscopic investigation of silicon heterojunction solar cells
    Holovsky, Jakub
    De Wolf, Stefaan
    Jiricek, Petr
    Ballif, Christophe
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (07):
  • [30] ATTENUATED TOTAL REFLECTANCE FOURIER-TRANSFORM INFRARED STUDIES OF CRYSTALLINE AMORPHOUS CONTENT ON POLYETHYLENE SURFACES
    HUANG, JB
    HONG, JW
    URBAN, MW
    POLYMER, 1992, 33 (24) : 5173 - 5178