Method for measuring veiling glare in high-performance display devices

被引:0
|
作者
机构
[1] [1,2,Badano, Aldo
[2] 1,Flynn, Michael J.
来源
Badano, A. (badano@umich.edu) | 2000年 / Optical Society of America (OSA)卷 / 39期
关键词
Cathode ray tubes - Display devices - Optical collimators - Radiography - Signal distortion;
D O I
暂无
中图分类号
学科分类号
摘要
An experimental method for measuring the veiling glare characteristics of display devices is presented. The measured veiling glare ratio (G) is taken to be the luminance in the surrounding bright field divided by the luminance in a dark circle. The method is based on a collimated conic probe that minimizes signal contamination from bright surroundings allowing for measurements of low luminance in a circular dark spot of a test pattern. A correction factor computed with test patterns having opaque spots is introduced. The factor is expressed as a bivariate function of the dark-spot radius and the distance between the probe and the emissive surface. We studied the uncertainty introduced by the method by measuring veiling glare test patterns printed on radiographic film for which the transmission of the dark spots was determined experimentally. Performance characterization measurements show that signal contamination is less than 10-4of the bright field surrounding a dark circle. Our results show that G of a few hundred can be measured with an uncertainty of a few percent, and ratios of approximately 103can be reported within 10%. Finally, we demonstrate the method by measuring G for a high-performance monochrome cathode-ray tube display. © 2000 Optical Society of America.
引用
收藏
相关论文
共 50 条
  • [21] A Proposal of High-Performance Method for Distance Measuring Sensor united with PSD
    Nakashima, Shota
    Nakamuta, Takafumi
    Kitazono, Yuhki
    Yang, Shiyuan
    Serikawa, Seiichi
    PRECISION INSTRUMENTATION AND MEASUREMENT, 2010, 36 : 365 - +
  • [22] High-Performance Passive-Matrix OLED Display by Colour Conversion Method
    Terao, Y.
    Kobayashi, M.
    Kanai, N.
    Makino, R.
    Li, C.
    Kawamura, Y.
    Kawaguchi, K.
    Saito, T.
    Hashida, H.
    Kimura, H.
    AOE 2007: ASIA OPTICAL FIBER COMMUNICATION & OPTOELECTRONIC EXPOSITION & CONFERENCE, CONFERENCE PROCEEDINGS, 2008, : 245 - +
  • [23] Using a human visual system model to optimize soft-copy mammography display: Influence of veiling glare
    Krupinski, EA
    Lubin, J
    Roehrig, H
    Johnson, J
    Nafziger, J
    ACADEMIC RADIOLOGY, 2006, 13 (03) : 289 - 295
  • [24] High-performance sustain driver for plasma display
    Kang, Feel-Soon
    Park, Sung-Jun
    Cho, Jang-Hwan
    Yoon, Won-Sik
    Kim, Cheul-U
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (04) : 1322 - 1327
  • [25] THE DEVELOPMENT OF HIGH-PERFORMANCE RDA DEVICES
    SOLIE, LP
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1980, 27 (03): : 164 - 165
  • [26] High-performance liquid chromatographic method for measuring total plasma homocysteine levels
    Fermo, I
    Arcelloni, C
    Mazzola, G
    D'Angelo, A
    Paroni, R
    JOURNAL OF CHROMATOGRAPHY B, 1998, 719 (1-2): : 31 - 36
  • [27] RAPID METHOD OF MEASURING SALICYLATE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHUBB, SAP
    CAMPBELL, RS
    PRICE, CP
    JOURNAL OF CHROMATOGRAPHY, 1986, 380 (01): : 163 - 169
  • [28] Daytime veiling glare and driver visual performance: Influence of windshield rake angle and dashboard reflectance
    Schumann, J
    Flannagan, MJ
    Sivak, M
    Traube, EC
    JOURNAL OF SAFETY RESEARCH, 1997, 28 (03) : 133 - 146
  • [29] UNIFORM VEILING LUMINANCE AND DISPLAY POLARITY AFFECT VDU USER PERFORMANCE
    SANDERS, PA
    BERNECKER, CA
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1990, 19 (02): : 113 - 123
  • [30] Does Veiling Glare in the Human Eye Hinder Detection in High-Dynamic-Range Displays?
    Choi, Mina
    Sharma, Diksha
    Zafar, Fahad
    Cheng, Wei-Chung
    Albani, Luigi
    Badano, Aldo
    JOURNAL OF DISPLAY TECHNOLOGY, 2012, 8 (05): : 273 - 282