Quantitative Analysis of Complex Aluminum Electrolytes by X-Ray Fluorescence

被引:0
|
作者
Tan, Qi [1 ]
Gao, Bingliang [1 ]
Gao, Pengde [2 ]
Fan, Chao [2 ]
Li, Haijun [2 ]
机构
[1] Northeastern Univ, Sch Met, Shenyang, Peoples R China
[2] Inner Mongolia Mengtai Co, Ordos, Peoples R China
关键词
aluminum electrolysis; complex aluminum electrolytes; cryolite ratio; quantitative X-ray fluorescence analysis; CRYOLITE; SYSTEM; LIF;
D O I
10.1002/bio.70013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The future production of electrolytic aluminum will be characterized by low temperature, low carbon emissions, and environmental friendliness, which will result in a more complex electrolyte system. Real-time analysis of electrolytes can significantly enhance the efficiency of the electrolytic process. However, accurately analyzing the composition of complex aluminum electrolytes online has been a technical challenge. This research primarily focuses on determining the ingredient contents of complex aluminum electrolytes based on elemental concentrations measured using X-ray fluorescence (XRF) according to an applicable standard. Calibration curves were established based on 53 standard samples of complex aluminum electrolytes to establish relationships between XRF fluorescence intensity and real concentrations. Analysis conducted on industrial complex electrolytes confirms that these newly constructed curves effectively reduce relative errors to less than 3%. Additionally, a feasible solution is proposed for determining the cryolite ratio (CR) in aluminum electrolytes using XRF. Results demonstrate an average deviation as low as approximately 0.02, fully meeting industrial production requirements. This technique offers numerous benefits including rapid analysis, ease of use, and cost savings.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Using Organic Slab to Obtain X-ray Tube Spectra for Quantitative Analysis of X-ray Fluorescence Analysis
    Liu, Song
    Li, Qinghui
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VIII, 2013, 8848
  • [22] DETERMINATION OF ALUMINUM IN CELLULOSE BY X-RAY FLUORESCENCE
    ANTWUORINEN, O
    VISAPAA, A
    PAPER JA PUU-PAPPER OCH TRA, 1969, 51 (4A): : 285 - +
  • [23] X-RAY FLUORESCENCE ANALYSIS
    BAREHAM, FR
    GIDLEY, JAF
    BUTLER, DH
    LINDSTROM
    POWELL, AR
    JOHNSON, W
    FOX, JGM
    COCKETT, GH
    JOURNAL OF THE INSTITUTE OF METALS, 1962, 90 (07): : 273 - &
  • [24] X-RAY FLUORESCENCE ANALYSIS
    OTTER, RJ
    MIKROCHIMICA ACTA, 1962, (05) : 983 - &
  • [25] ESTIMATION OF SPECTRAL DISTRIBUTION OF X-RAY TUBE FOR QUANTITATIVE X-RAY-FLUORESCENCE ANALYSIS
    MURATA, M
    SHIBAHARA, H
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 235 - 235
  • [26] X-RAY FLUORESCENCE ANALYSIS
    ROBERT, A
    BULLETIN DE LA SOCIETE FRANCAISE DE CERAMIQUE, 1968, (78): : 33 - &
  • [27] Quantitative X-Ray Fluorescence Analysis of Multielemental Subjects of Complex Shape without Implementation of Reference Standards
    Oskolok, K., V
    Garmay, A., V
    Monogarova, O., V
    MOSCOW UNIVERSITY CHEMISTRY BULLETIN, 2014, 69 (01) : 8 - 11
  • [28] X-ray fluorescence analysis with a pyroelectric x-ray generator
    Kawai, J
    Ida, H
    Murakami, H
    Koyama, T
    X-RAY SPECTROMETRY, 2005, 34 (06) : 521 - 524
  • [30] PECULIARITIES OF QUANTITATIVE X-RAY FLUORESCENCE ANALYSIS OF IRON IN CARBON MATRIX
    Mokhova, A. I.
    Naumova, V. A.
    Khaskov, M. A.
    Karaeva, A. R.
    Mordkovich, V. Z.
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII KHIMIYA I KHIMICHESKAYA TEKHNOLOGIYA, 2023, 66 (10): : 6 - 13