摘要
The fire safety requirements and knowledge on the use of Glass Fiber Reinforced Polymer (GFRP) bars as an alternative to conventional steel in reinforced concrete structures have been progressively evolving. This study investigates the post-fire axial performance of square GFRP reinforced concrete (RC) columns, addressing a significant gap in current knowledge. Five column specimens of the same cross-section and length were tested, where the main parameters considered are the clear cover depths (40, 50, and 65 mm) and the use of a 40-mm insulation on one column. The columns were subjected to a long 3-hour fire exposure per ASTM E119 standard without sustained loading. The columns were tested upon cooling under concentric axial loading. Despite the notable temperature differences between columns with 40 and 65 mm concrete cover (300 and 500 degrees C after 3 hours), the post-fire residual axial capacity appeared unaffected. This is primarily attributed to the minimal differences in the retained mechanical properties of GFRP bars at temperatures exceeding 200 degrees C. The study's findings indicate that GFRP longitudinal bars do not significantly influence the performance of columns in fires. Consequently, future research should focus on columns reinforced with GFRP ties as well. The predicted values of post-fire axial capacity closely match the experimental data for non-insulated columns, indicating a high degree of accuracy. The study provides design recommendations to enhance the fire performance of such elements. The use of insulation results in a substantial reduction of temperature at various depths of the column. Post-fire residual capacities for non-insulated columns were approximately 30 %, whereas insulated columns demonstrated a 60 % residual capacity.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Post-fire seismic performance of steel-reinforced concrete frames: Experiment
    Wang, Guang-yong
    Cui, Xing-chen
    Li, Zheng
    Liu, Ren-jie
    STRUCTURES, 2024, 66
  • [22] Post-fire behaviour of eccentrically loaded reinforced concrete columns confined by circular steel tubes
    Liu, Faqi
    Yang, Hua
    Gardner, Leroy
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 495 - 510
  • [23] Self-Centering Hybrid GFRP-Steel Reinforced Concrete Beams for Blast Resilience
    Johnson, Jalen
    Xu, Man
    Jacques, Eric
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (07)
  • [24] Post-fire test of precast steel reinforced concrete stub columns under eccentric compression
    Yang, Yong
    Xue, Yicong
    Yu, Yunlong
    Gong, Zhichao
    STEEL AND COMPOSITE STRUCTURES, 2019, 33 (01): : 111 - 122
  • [25] POST-FIRE PERFORMANCE OF ELLIPTICAL CONCRETE-FILLED STEEL TUBE STUB COLUMNS
    Song, T. Y.
    Zhang, J. C.
    Xiang, K.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1459 - 1469
  • [26] Experimental Study of Post-fire Performance of Ceramsite Concrete Filled Steel Tabular Columns
    Wang, Xintang
    Yin, Jie
    Zhou, Ming
    Wang, Jianmin
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3733 - 3736
  • [27] The Effects of Reinforcement Ratio on Flexural Behavior in Hybrid (GFRP-Steel) Reinforced Concrete Beams
    Kaya, Nalan
    Avanoglu Sicacik, Eda
    Bakirci Er, Sule
    Kopraman, Yagmur
    Buyukkaragoz, Alper
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2021, 24 (03): : 1109 - 1119
  • [28] Post-fire seismic performance of reinforced concrete structures
    Duzgun, Oguz Akin
    Kucuk, Elif Nazli
    STRUCTURES, 2024, 59
  • [29] Assessment of reinforced concrete slabs post-fire performance
    Shachar, Yedidya M.
    Dancygier, Avraham N.
    FIRE SAFETY JOURNAL, 2020, 111
  • [30] An Experimental Evaluation on the Fire Resistance and Post-fire Structural Performance of Concrete Filled Steel Tube Columns
    Minjoung Kang
    Younghan Choi
    Sungbae Kim
    Sangseup Kim
    International Journal of Steel Structures, 2022, 22 : 1734 - 1742