Post-fire performance of hybrid GFRP-steel reinforced concrete columns

被引:0
|
作者
Khalaf, Salem [1 ]
Abed, Farid [1 ]
Roshan, Naeim [2 ]
Hajiloo, Hamzeh [2 ]
机构
[1] Department of Civil Engineering, American University of Sharjah
[2] Department of Civil and Environmental Engineering, Carleton University, Canada
关键词
Bars (metal) - Columns (structural) - Concrete buildings - Concrete construction - Elastomers - Fiber reinforced concrete - Fireproofing - Fires - Glass fiber reinforced plastics - Premixed flames - Steel fibers;
D O I
10.1016/j.conbuildmat.2024.138655
中图分类号
学科分类号
摘要
The fire safety requirements and knowledge on the use of Glass Fiber Reinforced Polymer (GFRP) bars as an alternative to conventional steel in reinforced concrete structures have been progressively evolving. This study investigates the post-fire axial performance of square GFRP reinforced concrete (RC) columns, addressing a significant gap in current knowledge. Five column specimens of the same cross-section and length were tested, where the main parameters considered are the clear cover depths (40, 50, and 65 mm) and the use of a 40-mm insulation on one column. The columns were subjected to a long 3-hour fire exposure per ASTM E119 standard without sustained loading. The columns were tested upon cooling under concentric axial loading. Despite the notable temperature differences between columns with 40 and 65 mm concrete cover (300 and 500 °C after 3 hours), the post-fire residual axial capacity appeared unaffected. This is primarily attributed to the minimal differences in the retained mechanical properties of GFRP bars at temperatures exceeding 200 °C. The study's findings indicate that GFRP longitudinal bars do not significantly influence the performance of columns in fires. Consequently, future research should focus on columns reinforced with GFRP ties as well. The predicted values of post-fire axial capacity closely match the experimental data for non-insulated columns, indicating a high degree of accuracy. The study provides design recommendations to enhance the fire performance of such elements. The use of insulation results in a substantial reduction of temperature at various depths of the column. Post-fire residual capacities for non-insulated columns were approximately 30 %, whereas insulated columns demonstrated a 60 % residual capacity. © 2024 The Authors
引用
收藏
相关论文
共 50 条
  • [1] Post-fire performance of steel reinforced concrete columns with different steel sections
    Hassani, Meisam
    Safi, Mohammad
    Ardakani, Reza Rasti
    Daryan, Amir Saedi
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (16) : 3724 - 3738
  • [2] Performance-Based Seismic Design of Hybrid GFRP-Steel Reinforced Concrete Bridge Columns
    Osman, Sherif M. S.
    Aldabagh, Saif
    Alam, M. Shahria
    Sheikh, Shamim A. A.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2023, 27 (02)
  • [3] Fire and post-fire performance of circular steel tube confined reinforced concrete columns
    Liu, F.
    Yang, H.
    Zhang, S.
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 787 - 793
  • [4] Experimental research on post-fire seismic performance of steel reinforced concrete columns
    Wang, Guang-Yong
    Shi, Yi
    Zhang, Dong-Ming
    Zheng, Chan-Chan
    [J]. Gongcheng Lixue/Engineering Mechanics, 2015, 32 (11): : 160 - 169
  • [5] Experimental Research on the Post-fire Seismic Performance of Steel Reinforced Concrete Columns
    Wang Guangyong
    Zhang Dongming
    [J]. PERFORMANCE OF MATERIALS AND STRUCTURES UNDER EXTREME CONDITIONS, 2017, 210 : 456 - 463
  • [6] Flexural performance of hybrid GFRP-Steel reinforced concrete continuous beams
    Araba, Almandi Mohamed
    Ashour, Ashraf F.
    [J]. COMPOSITES PART B-ENGINEERING, 2018, 154 : 321 - 336
  • [7] Test and parametric analysis on post-fire seismic performance of steel reinforced concrete columns
    China Academy of Building Research, Beijing
    100013, China
    不详
    518000, China
    [J]. Tumu Gongcheng Xuebao, 7 (60-70):
  • [8] Explosion resistance of hybrid GFRP-steel reinforced concrete slab
    Han Z.
    Qu W.
    [J]. Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2023, 40 (12): : 6718 - 6728
  • [9] Modeling of tensile behavior of hybrid GFRP-steel reinforced concrete chords
    Zhou, Binbin
    Wu, Ruo-Yang
    Feng, Jian
    Yin, Shiping
    [J]. COMPOSITE STRUCTURES, 2020, 236 (236)
  • [10] Post-fire performance of GFRP reinforced concrete deep beams: experimental and numerical study
    Shabanlou, Mohammad
    Mofid, Massood
    Tavakoli, Amirali
    [J]. STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2024,