Patient-specific aortic phantom with tunable compliance

被引:5
|
作者
Gallarello, Antonio [1 ]
Palombi, Andrea [2 ]
Annio, Giacomo [2 ]
Homer-Vanniasinkam, Shervanthi [3 ]
de Momi, Elena [1 ]
Maritati, Gabriele [4 ]
Torii, Ryo [2 ]
Burriesci, Gaetano [2 ,5 ]
Wurdemann, Helge A. [2 ]
机构
[1] Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milano,20133, Italy
[2] Department of Mechanical Engineering, University College, London,WC1E 7JE, United Kingdom
[3] Leeds Vascular Institute, Leeds General Infirmary, Leeds,LS1 3EX, United Kingdom
[4] Vascular and Endovascular Unit, Perrino Hospital, ASL-Br, Brindisi,72100, Italy
[5] Ri.MED Foundation, Via Bandiera 11, Palermo,90133, Italy
基金
英国工程与自然科学研究理事会;
关键词
Computerized tomography - Magnetic resonance imaging - Elastic moduli - Arches - Blood vessels - Medical imaging - Silicones;
D O I
10.1115/1.4044611
中图分类号
学科分类号
摘要
Validation of computational models using in vitro phantoms is a nontrivial task, especially in the replication of the mechanical properties of the vessel walls, which varies with age and pathophysiological state. In this paper, we present a novel aortic phantom reconstructed from patient-specific data with variable wall compliance that can be tuned without recreating the phantom. The three-dimensional (3D) geometry of an aortic arch was retrieved from a computed tomography angiography scan. A rubber-like silicone phantom was manufactured and connected to a compliance chamber in order to tune its compliance. A lumped resistance was also coupled with the system. The compliance of the aortic arch model was validated using the Young's modulus and characterized further with respect to clinically relevant indicators. The silicone model demonstrates that compliance can be finely tuned with this system under pulsatile flow conditions. The phantom replicated values of compliance in the physiological range. Both, the pressure curves and the asymmetrical behavior of the expansion, are in agreement with the literature. This novel design approach allows obtaining for the first time a phantom with tunable compliance. Vascular phantoms designed and developed with the methodology proposed in this paper have high potential to be used in diverse conditions. Applications include training of physicians, pre-operative trials for complex interventions, testing of medical devices for cardiovascular diseases (CVDs), and comparative Magnetic-resonance-imaging (MRI)-based computational studies. Copyright © 2019 by ASME
引用
收藏
相关论文
共 50 条
  • [1] A patient-specific multi-modality abdominal aortic aneurysm imaging phantom
    Little, Callum D.
    Mackle, Eleanor C.
    Maneas, Efthymios
    Chong, Debra
    Nikitichev, Daniil
    Constantinou, Jason
    Tsui, Janice
    Hamilton, George
    Rakhit, Roby D.
    Mastracci, Tara M.
    Desjardins, Adrien E.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (09) : 1611 - 1617
  • [2] A patient-specific multi-modality abdominal aortic aneurysm imaging phantom
    Callum D. Little
    Eleanor C. Mackle
    Efthymios Maneas
    Debra Chong
    Daniil Nikitichev
    Jason Constantinou
    Janice Tsui
    George Hamilton
    Roby D. Rakhit
    Tara M. Mastracci
    Adrien E. Desjardins
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1611 - 1617
  • [3] Design and manufacture of a patient-specific phantom for Dosimetry analysis
    Gear, J. I.
    Cummings, C.
    Partridge, M.
    Flux, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S178 - S178
  • [4] Phantom-and patient-specific dose calculations for CT
    Schmidt, B
    Kalender, WA
    RADIOLOGY, 2002, 225 : 592 - 592
  • [5] Patient-specific ascending aortic intervention criteria
    Kalogerakos, Paris D.
    Zafar, Mohammad A.
    Li, Yupeng
    Ellauzi, Hesham
    Mukherjee, Sandip K.
    Ziganshin, Bulat A.
    Rizzo, John A.
    Elefteriades, John A.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 65 (05)
  • [6] Patient-specific ultrasound liver phantom: materials and fabrication method
    Alessia Pacioni
    Marina Carbone
    Cinzia Freschi
    Rosanna Viglialoro
    Vincenzo Ferrari
    Mauro Ferrari
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1065 - 1075
  • [7] Evaluation of a Phantom for Patient-specific Quality Assurance in the MR Linac
    Baumgartl, M.
    Safarkhanlo, Y.
    Ehrbar, S.
    Wilke, L.
    Krayenbuhl, J.
    Chamberlain, M.
    Zamburlini, M.
    Guckenberger, M.
    Andratschke, N.
    Tanadini-Lang, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (SUPPL 1) : S33 - S34
  • [8] Patient-specific ultrasound liver phantom: materials and fabrication method
    Pacioni, Alessia
    Carbone, Marina
    Freschi, Cinzia
    Viglialoro, Rosanna
    Ferrari, Vincenzo
    Ferrari, Mauro
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (07) : 1065 - 1075
  • [9] VMAT Commissioning and Patient-Specific QA Using MatriXX Phantom
    Bao, A.
    Geis, P.
    Zheng, Y.
    Pereira, G.
    Petchler, N. Kuc
    Elconin, J.
    Machtay, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E273 - E274
  • [10] Design and additive manufacture of patient-specific head phantom for radiotherapy
    Lin, Brandon Zhan Hong
    Zhang, Ee Teng
    Ng, Huiyan
    Tan, Mervin Yen Leong
    Soh, Zheng Han
    Wong, Yun Ming
    Chua, Clifford Ghee Ann
    Lew, Kah Seng
    Pang, Eric Pei Ping
    Tan, Hong Qi
    Park, Sung Yong
    Ng, Bing Feng
    Koh, Wei Yang Calvin
    MATERIALS & DESIGN, 2025, 252