Patient-specific aortic phantom with tunable compliance

被引:5
|
作者
Gallarello, Antonio [1 ]
Palombi, Andrea [2 ]
Annio, Giacomo [2 ]
Homer-Vanniasinkam, Shervanthi [3 ]
de Momi, Elena [1 ]
Maritati, Gabriele [4 ]
Torii, Ryo [2 ]
Burriesci, Gaetano [2 ,5 ]
Wurdemann, Helge A. [2 ]
机构
[1] Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milano,20133, Italy
[2] Department of Mechanical Engineering, University College, London,WC1E 7JE, United Kingdom
[3] Leeds Vascular Institute, Leeds General Infirmary, Leeds,LS1 3EX, United Kingdom
[4] Vascular and Endovascular Unit, Perrino Hospital, ASL-Br, Brindisi,72100, Italy
[5] Ri.MED Foundation, Via Bandiera 11, Palermo,90133, Italy
基金
英国工程与自然科学研究理事会;
关键词
Computerized tomography - Magnetic resonance imaging - Elastic moduli - Arches - Blood vessels - Medical imaging - Silicones;
D O I
10.1115/1.4044611
中图分类号
学科分类号
摘要
Validation of computational models using in vitro phantoms is a nontrivial task, especially in the replication of the mechanical properties of the vessel walls, which varies with age and pathophysiological state. In this paper, we present a novel aortic phantom reconstructed from patient-specific data with variable wall compliance that can be tuned without recreating the phantom. The three-dimensional (3D) geometry of an aortic arch was retrieved from a computed tomography angiography scan. A rubber-like silicone phantom was manufactured and connected to a compliance chamber in order to tune its compliance. A lumped resistance was also coupled with the system. The compliance of the aortic arch model was validated using the Young's modulus and characterized further with respect to clinically relevant indicators. The silicone model demonstrates that compliance can be finely tuned with this system under pulsatile flow conditions. The phantom replicated values of compliance in the physiological range. Both, the pressure curves and the asymmetrical behavior of the expansion, are in agreement with the literature. This novel design approach allows obtaining for the first time a phantom with tunable compliance. Vascular phantoms designed and developed with the methodology proposed in this paper have high potential to be used in diverse conditions. Applications include training of physicians, pre-operative trials for complex interventions, testing of medical devices for cardiovascular diseases (CVDs), and comparative Magnetic-resonance-imaging (MRI)-based computational studies. Copyright © 2019 by ASME
引用
收藏
相关论文
共 50 条
  • [31] Patient-Specific Biomechanics in Marfan Ascending Thoracic Aortic Aneurysms
    Xuan, Yue
    D'Souza, Sara N.
    Wang, Zhongjie
    Pierre, Alejandro Suarez
    Lawton, Jennifer S.
    Ge, Liang
    Tseng, Elaine E.
    ANNALS OF THORACIC SURGERY, 2022, 114 (04): : 1367 - 1375
  • [32] Patient-specific aortic endografting simulation: From diagnosis to prediction
    Auricchio, F.
    Conti, M.
    Marconi, S.
    Reali, A.
    Tolenaar, Jip L.
    Trimarchi, S.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (04) : 386 - 394
  • [33] Virtual Planning and Patient-Specific Graft Design for Aortic Repairs
    Aslan, Seda
    Liu, Xiaolong
    Wu, Qiyuan
    Mass, Paige
    Loke, Yue-Hin
    Johnson, Jed
    Huddle, Joey
    Olivieri, Laura
    Hibino, Narutoshi
    Krieger, Axel
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2024, 15 (02) : 123 - 136
  • [34] Patient-specific simulations of transcatheter aortic valve stent implantation
    C. Capelli
    G. M. Bosi
    E. Cerri
    J. Nordmeyer
    T. Odenwald
    P. Bonhoeffer
    F. Migliavacca
    A. M. Taylor
    S. Schievano
    Medical & Biological Engineering & Computing, 2012, 50 : 183 - 192
  • [35] Review of patient-specific simulations of transcatheter aortic valve implantation
    Vy, P.
    Auffret, V.
    Badel, P.
    Rochette, M.
    Le Breton, H.
    Haigron, P.
    Avril, S.
    INTERNATIONAL JOURNAL OF ADVANCES IN ENGINEERING SCIENCES AND APPLIED MATHEMATICS, 2016, 8 (01) : 2 - 24
  • [36] Patient-Specific Computational Modeling of Transcatheter Aortic Valve Implantation
    Ge, Liang
    Azadani, Ali
    Chitsaz, Sam
    Mookhoek, Aart
    Wisneski, Andrew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B265 - B265
  • [37] Analysis of Flow Patterns in a Patient-Specific Aortic Dissection Model
    Cheng, Z.
    Tan, F. P. P.
    Riga, C. V.
    Bicknell, C. D.
    Hamady, M. S.
    Gibbs, R. G. J.
    Wood, N. B.
    Xu, X. Y.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (05):
  • [38] Towards patient-specific risk assessment of abdominal aortic aneurysm
    Breeuwer, M.
    de Putter, S.
    Kose, U.
    Speelman, L.
    Visser, K.
    Gerritsen, F.
    Hoogeveen, R.
    Krams, R.
    van den Bosch, H.
    Buth, J.
    Gunther, T.
    Wolters, B.
    van Dam, E.
    van de Vosse, F.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (11) : 1085 - 1095
  • [39] Fabrication of a patient-specific metastasized lumbar vertebra phantom with realistic attenuation properties
    Pieper, L.
    Theisen, A.
    Lassmann, M.
    Ramirez, M. Salas
    Tran-Gia, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S699 - S699
  • [40] Development of a patient-specific simulation tool to analyse aortic dissections: Assessment of mixed patient-specific flow and pressure boundary conditions
    Alimohammadi, Mona
    Agu, Obiekezie
    Balabani, Stavroula
    Diaz-Zuccarini, Vanessa
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (03) : 275 - 284