Experimental evaluation of the ventilation effects on the performance of a VRV system in cooling mode - Part I: Experimental evaluation

被引:0
|
作者
Aynur, Tolga N. [1 ]
Hwang, Yunho [1 ]
Radermacher, Reinhard [1 ]
机构
[1] Department of Mechanical Engineering, Center Environmental Energy Engineering, University of Maryland, College Park, MD, United States
来源
HVAC and R Research | 2008年 / 14卷 / 04期
关键词
Space heating - Energy utilization - Energy efficiency - Humidity control - Temperature control;
D O I
暂无
中图分类号
学科分类号
摘要
The effect of ventilation on indoor temperature control, thermal comfort, outdoor unit energy consumption, and efficiency of the multi-split variable refrigerant volume (VRV) system is investigated in afield test under varying outdoor conditions. It is observed through the experiments that ventilation does not affect the indoor temperature control of the multi-split VRV system; instead it increases the indoor humidity ratio, resulting in a less comfortable indoor environment. Even though ventilation increases the outdoor unit energy consumption due to the ventilation load, it does not have a considerable effect on the efficiency of the multi-split VRV system.
引用
收藏
页码:615 / 630
相关论文
共 50 条
  • [31] Performance evaluation of a novel plate-type porous indirect evaporative cooling system: An experimental study
    Shi, Wenchao
    Min, Yunran
    Ma, Xiaochen
    Chen, Yi
    Yang, Hongxing
    JOURNAL OF BUILDING ENGINEERING, 2022, 48
  • [32] Evaluation of the ventilation unit for personal cooling system (PCS)
    Yi, Wen
    Zhao, Yijie
    Chan, Albert P. C.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2017, 58 : 62 - 68
  • [33] Experimental performance evaluation of direct cooling of hot stamping dies using fractal cooling channels
    Lee, Sewon
    Kwon, Junho
    Lee, Dongchan
    Baek, Changhyun
    Jin, Hongkyo
    Kim, Yongchan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [34] Experimental evaluation of PROFINET performance
    Ferrari, P
    Flammini, A
    Marioli, D
    Taroni, A
    WFCS 2004: IEEE INTERNATIONAL WORKSHOP ON FACTORY COMMUNICATION SYSTEMS, PROCEEDINGS, 2004, : 331 - 334
  • [35] Experimental investigation and the performance evaluation of a mixed mode solar dryer for coconut
    Subbian, V.
    Murugavel, K. Kalidasa
    Raja, R. Satheesh
    Shanawaz, A. M.
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 3662 - 3665
  • [36] Experimental evaluation of the cooling performance of radiant ceiling panels with thermal energy storage
    Gallardo, Andres
    Berardi, Umberto
    ENERGY AND BUILDINGS, 2022, 262
  • [37] Experimental evaluation of the performance of vacuum cooling method for large cooked meat joints
    Wang, LJ
    Sun, DW
    JOURNAL OF FOOD PROCESS ENGINEERING, 2002, 25 (05) : 455 - 472
  • [38] Experimental performance evaluation and modeling of jet impingement cooling for thermal management of photovoltaics
    Bahaidarah, Haitham M. S.
    SOLAR ENERGY, 2016, 135 : 605 - 617
  • [39] Experimental performance evaluation of a convective thermoelectric building envelope for building heating and cooling
    Liu, Xiaoli
    Yazawa, Kazuaki
    Qu, Ming
    Kurtulus, Orkan
    Norton, Brian
    Holmes, Niall
    Jani, Ruchita
    Kohanoff, Jorge
    Stella, Lorenzo
    Johnston, Conrad
    Yin, Hongxi
    ENERGY AND BUILDINGS, 2022, 273
  • [40] Experimental study on evaluation index of indirect evaporative cooling heat transfer performance
    Guo, Chunmei
    Chen, Tong
    Bin Zheng
    Liu, Qinghhua
    Lv, Jian
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5789 - 5794