High-resolution, high-sensitivity, ground-based solar spectropolarimetry with a new fast imaging polarimeter: I. Prototype characterization

被引:0
|
作者
Iglesias, F.A. [1 ]
Feller, A. [1 ]
Nagaraju, K. [1 ,2 ]
Solanki, S.K. [1 ,3 ]
机构
[1] Max-Planck Institute for Solar System Research, Justus-von-Liebig-Weg 3, Göttingen, Germany
[2] Indian Institute of Astrophysics, Koramangala Second Block, Bengaluru,560034, India
[3] School of Space Research, Kyung Hee University, Yongin, Gyeonggi-Do,446-701, Korea, Republic of
来源
Astronomy and Astrophysics | 2016年 / 590卷
基金
新加坡国家研究基金会;
关键词
Frequency modulation - Image reconstruction - Magnetic fields - Image resolution - Remote sensing - Convolution - Polarimeters - Restoration;
D O I
暂无
中图分类号
学科分类号
摘要
Context. Remote sensing of weak and small-scale solar magnetic fields is of utmost relevance when attempting to respond to a number of important open questions in solar physics. This requires the acquisition of spectropolarimetric data with high spatial resolution (~10-1 arcsec) and low noise (10-3 to 10-5 of the continuum intensity). The main limitations to obtain these measurements from the ground, are the degradation of the image resolution produced by atmospheric seeing and the seeing-induced crosstalk (SIC). Aims. We introduce the prototype of the Fast Solar Polarimeter (FSP), a new ground-based, high-cadence polarimeter that tackles the above-mentioned limitations by producing data that are optimally suited for the application of post-facto image restoration, and by operating at a modulation frequency of 100 Hz to reduce SIC. Methods. We describe the instrument in depth, including the fast pnCCD camera employed, the achromatic modulator package, the main calibration steps, the effects of the modulation frequency on the levels of seeing-induced spurious signals, and the effect of the camera properties on the image restoration quality. Results. The pnCCD camera reaches 400 fps while keeping a high duty cycle (98.6%) and very low noise (4.94 e- rms). The modulator is optimized to have high (>80%) total polarimetric efficiency in the visible spectral range. This allows FSP to acquire 100 photon-noise-limited, full-Stokes measurements per second. We found that the seeing induced signals that are present in narrow-band, non-modulated, quiet-sun measurements are (a) lower than the noise (7 × 10-5) after integrating 7.66 min, (b) lower than the noise (2.3 × 10-4) after integrating 1.16 min and (c) slightly above the noise (4 × 10-3) after restoring case (b) by means of a multi-object multi-frame blind deconvolution. In addition, we demonstrate that by using only narrow-band images (with low S/N of 13.9) of an active region, we can obtain one complete set of high-quality restored measurements about every 2 s. © ESO, 2016.
引用
收藏
相关论文
共 50 条
  • [41] High-resolution and high-sensitivity blood flow estimation using optimization approaches with application to vascularization imaging
    Shen, H.
    Barthelemy, C.
    Khoury, E.
    Zemmoura, Y.
    Remenieras, Jp.
    Basarab, A.
    Kouame, D.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 467 - 470
  • [42] Detection of Temporal and Spatial Distributions of Atmospheric Nitric Acid Based on Ground-Based High-Resolution Solar Absorption Spectra
    Zhang Huifang
    Wang Wei
    Liu Cheng
    Shan Changgong
    Hu Qihou
    Sun Youwen
    Jones, Nicholas
    ACTA OPTICA SINICA, 2020, 40 (02)
  • [43] Hexapod Actuated Focal Plane for High-Resolution Suborbital and Ground-Based Exploration
    Miller, Alexander D.
    Scowen, Paul A.
    Holton, Rhonda K.
    Prathipati, Ravi
    Veach, Todd J.
    Ramirez, Ronnie
    Challa, Priya
    Camarena, Raquel
    SPACE TELESCOPES AND INSTRUMENTATION 2018: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2018, 10698
  • [44] Performance comparison of CMOS-based photodiodes for high-resolution and high-sensitivity digital mammography
    Bae, J. H.
    Cho, M.
    Kim, M. S.
    Lee, D. H.
    Cho, G.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [45] HIGH-RESOLUTION GROUND-BASED CORONAGRAPHY USING IMAGE-MOTION COMPENSATION
    GOLIMOWSKI, DA
    CLAMPIN, M
    DURRANCE, ST
    BARKHOUSER, RH
    APPLIED OPTICS, 1992, 31 (22): : 4405 - 4416
  • [46] Isotopic OCS from high-resolution balloon-borne and ground-based infrared solar absorption spectra
    Goldman, A
    Coffey, MT
    Stephen, TM
    Rinsland, CP
    Mankin, WG
    Hannigan, JW
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2000, 67 (06): : 447 - 455
  • [47] Conceptual design for the High Resolution Optical Spectrograph on the Thirty-Meter Telescope: a new concept for a ground-based high-resolution optical spectrograph
    Froning, Cynthia
    Osterman, Steven
    Beasley, Matthew
    Green, James
    Beland, Stephane
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY, PTS 1- 3, 2006, 6269
  • [48] High-resolution imaging and spectroscopy in the visible from large ground-based telescopes with natural guide stars.
    Mackay, Craig
    Staley, Tim D.
    King, David
    Suess, Frank
    Weller, Keith
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY III, 2010, 7735
  • [49] A pixelated liquid perovskite array for high-sensitivity and high-resolution X-ray imaging scintillation screens
    Hu, Mingzhu
    Wang, Yumeng
    Hu, Shengpeng
    Wang, Zongpeng
    Du, Bi
    Peng, Yanjun
    Yang, Jiawei
    Shi, Yunjie
    Chen, Dongdong
    Chen, Xi
    Zhuang, Ziwen
    Wang, Zhixun
    Chen, Xi
    Yang, Jiecheng
    Ge, Yongshuai
    Wang, Eyu
    Wen, Quan
    Xiao, Shuang
    Ma, Ming
    Li, Weimin
    Zhang, Jie
    Ning, De
    Wei, Lei
    Yang, Chunlei
    Chen, Ming
    NANOSCALE, 2023, 15 (38) : 15635 - 15642
  • [50] High-resolution and high-sensitivity X-ray ptychographic coherent diffraction imaging using the CITIUS detector
    Takahashi, Yukio
    Abe, Masaki
    Uematsu, Hideshi
    Takazawa, Shuntaro
    Sasaki, Yuhei
    Ishiguro, Nozomu
    Ozaki, Kyosuke
    Honjo, Yoshiaki
    Nishino, Haruki
    Kobayashi, Kazuo
    Hiraki, Toshiyuki Nishiyama
    Joti, Yasumasa
    Hatsui, Takaki
    JOURNAL OF SYNCHROTRON RADIATION, 2023, 30 : 989 - 994