Influence of supply temperature and booster technology on the energetic performance and levelized cost of heat of a district heating network with central heat pump

被引:0
|
作者
Degelin, A. [1 ,2 ]
Tassenoy, R. [1 ]
Vieren, E. [1 ]
Demeester, T. [1 ]
T'Jollyn, I. [2 ]
De Paepe, M. [1 ,3 ,4 ]
机构
[1] Univ Ghent, Dept Electromech Syst & Met Engn, Sint Pietersnieuwstr 41, B-9000 Ghent, Belgium
[2] Univ Antwerp, Fac Appl Engn, EMIB, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
[3] UGent, FlandersMake, Core Lab MIRO, B-9000 Ghent, Belgium
[4] Univ Cape Town, Dept Mech Engn, Private Bag X3, ZA-7701 Rondebosch, South Africa
关键词
Low-temperature district heating; Central heat pump; Booster heat pump; Modelica; Energy system analysis; Levelized cost of heat; BUILDINGS; SYSTEM; FRICTION; IMPACT;
D O I
10.1016/j.energy.2024.133589
中图分类号
O414.1 [热力学];
学科分类号
摘要
The development of new low-temperature district heating networks in existing urban areas can accelerate the replacement of fossil-fuel-based heating systems by collective heating using electricity or renewable heat sources. Buildings can either be connected to the network in their current, non-refurbished state for rapid deployment or be refurbished before connection to achieve maximum energy efficiency. To assess the difference between these two strategies, this paper examines eight low-temperature district heating concepts with central heat pump, comparing their energy use and levelized cost of heat. The study includes four scenarios for each strategy, considering supply temperatures ranging from 10 degrees C to 75 degrees C. Heat pumps or electric heaters are used as booster technology when the network supply temperature is too low for space heating or domestic hot water purposes. The use of booster heat pumps shows the highest seasonal coefficient of performance for both refurbished (4.61) and non-refurbished buildings (3.43). However, booster technologies result in the highest levelized cost of heat, driven mainly by the high investment cost of the network and booster units. Lowest levelized cost of heat of 213 <euro>/MWhth is obtained for non-refurbished buildings at 75 degrees C and 297 <euro>/MWhth for refurbished buildings at 55 degrees C without boosters.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Model predictive control for a heat booster substation in ultra low temperature district heating systems
    Hermansen, Rune
    Smith, Kevin
    Thorsen, Jan Eric
    Wang, Jiawei
    Zong, Yi
    ENERGY, 2022, 238
  • [32] Energetic performance analysis of a ground-source heat pump system with latent heat storage for a greenhouse heating
    Benli, Huseyin
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) : 581 - 589
  • [33] Influence of house substation regulators on heat storage in district heating network
    Lichota, J.
    Prace Naukowe Instytutu Techniki Cieplnej i Mechaniki Plynow Politechniki Wroclawskiej, 2000, 2 : 113 - 119
  • [34] Application of thermohydraulic dispatcher in low temperature district heating systems for decreasing heat carrier transportation energy cost and increasing reliability of heat supply
    Yavorovsky, Y. V.
    Romanov, D. O.
    Sennikov, V. V.
    Sultanguzin, I. A.
    Malenkov, A. S.
    Zhigulina, E. V.
    Lulaev, A. V.
    INTERNATIONAL CONFERENCE PROBLEMS OF THERMAL PHYSICS AND POWER ENGINEERING (PTPPE-2017), 2017, 891
  • [35] STEAM DRIVEN ABSORPTION HEAT PUMP AND FLUE GAS CONDENSER APPLIED FOR HEAT RECOVERY IN DISTRICT HEATING NETWORK
    Rusovs, Dmitrijs
    Zentins, Varis
    19TH INTERNATIONAL SCIENTIFIC CONFERENCE ENGINEERING FOR RURAL DEVELOPMENT, 2020, : 1627 - 1632
  • [36] Comparison of traditional district heating with low temperature district heating systems featuring organic Rankine cycle and heat pump
    Mikielewicz, Jaros law
    Mikielewicz, Dariusz
    ENERGY, 2023, 281
  • [37] Performance Investigation of An Air Source Heat Pump for Residential Heat Supply Through PCM Underfloor Heating
    Huang, Ming Jun
    Hewitt, Neil J.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 1763 - 1771
  • [38] Integration of booster heat pumps in ultra-low temperature district heating network: Prototype demonstration and refrigerant charge investigation
    Zhu, Tingting
    Du, Yanjun
    Liang, Jierong
    Rohlfs, Wilko
    Thorsen, Jan Eric
    Elmegaard, Brian
    ENERGY AND BUILDINGS, 2023, 298
  • [39] Study on the optimal heat supply control algorithm for district heating distribution network in response to outdoor air temperature
    Byun, Sun-Joon
    Park, Hyun-Sik
    Yi, Sung-Jae
    Song, Chul-Hwa
    Choi, Young-Don
    Lee, So-Hyeon
    Shin, Jong-Keun
    ENERGY, 2015, 86 : 247 - 256
  • [40] Study on Simulation Performance of Solar Energy and Gas Heat Pump for Heating Supply
    Hao, Hong
    Mao, Ligong
    Feng, Guohui
    Wen, Huating
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1482 - 1489