Circulating current analysis and robust droop multiple loop control method for parallel inverters using resistive output impedance

被引:0
|
作者
Chen, Yandong [1 ]
Luo, An [1 ]
Long, Jigen [1 ]
Peng, Ziqiang [1 ]
Zhang, Qinghai [1 ]
Lü, Zhipeng [2 ]
机构
[1] College of Electrical and Information Engineering, Hunan University, Changsha 410082, Hunan Province, China
[2] China Electric Power Research Institute, Haidian District, Beijing 100192, China
关键词
Circulating current - Droop controllers - Inverter parallels - Micro grid - Power sharing - Proportional resonant controllers - Virtual impedance;
D O I
暂无
中图分类号
学科分类号
摘要
For parallel multi-inverters in island microgrid, the difference of equivalent output impedance and line impedance affects greatly on power sharing and circulating current restraining. From power transmission characteristics of parallel inverters, the influence of power sharing among resistive inverters was analyzed in this paper, where the conventional droop control was applied. Based on the analysis of circulating current characteristics of resistive inverters, a robust droop multiple loop control method was proposed, which included the outer power loop and the inner voltage and current loop. In the outer power loop, a robust droop controller is adopted to reduce the effects on accurate power sharing due to the impedance difference. Introducing virtual complex impedance including resistive component and inductive component, the equivalent output impedance of inverters is redesigned as pure resistance. Quasi proportional-resonant (QPR) control is applied to realize zero steady-state errors control of the output voltage with wide bandwidth for parallel inverters, which will reduce further the deviation of output voltage and restrain circulating current. The output voltage feedforward control and the proportional control of the capacitor current are adopted to improve the transient response and current disturbance. The effects on the equivalent output impedance in the different control mode and parameters were analyzed comparatively, and the proper parameters were selected. Simulation and experimental results show the correctness and validity of the proposed control method. © 2013 Chinese Society for Electrical Engineering.
引用
收藏
页码:18 / 29
相关论文
共 50 条
  • [31] Droop control method with virtual output impedance for parallel operation of uninterruptible power supply systems in a microgrid
    Guerrero, Josep A.
    Berbel, Nestor
    Matas, Jose
    Sosa, Jorge L.
    de Vicuna, Luis Garcia
    APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2007, : 1126 - +
  • [32] Multiple resonant inverters in parallel with a novel current sharing control based on current decomposition method
    Ye Zhongming
    Praveen, Jain
    Paresh, Sen
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 1517 - +
  • [33] Analysis of Current Control Interaction of Multiple Parallel Grid-Connected Inverters
    Cavazzana, Francesco
    Caldognetto, Tommaso
    Mattavelli, Paolo
    Corradin, Michele
    Toigo, Igino
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2018, 9 (04) : 1740 - 1749
  • [34] Two-Parameter Stability Analysis of Resistive Droop Control Applied to Parallel-Connected Voltage-Source Inverters
    Lenz, Eduardo
    Pagano, Daniel J.
    Ruseler, Adriano
    Heldwein, Marcelo Lobo
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2020, 8 (04) : 3318 - 3332
  • [35] Output impedance performance for parallel operation of UPS inverters using wireless and average current-sharing controllers
    Guerrero, JM
    de Vicuña, LG
    Miret, J
    Matas, J
    Cruz, J
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 2482 - 2488
  • [36] Circulating current suppression method of grid-connected inverters in parallel using serial communication
    Jeon S.-B.
    Cho S.-J.
    Lee K.-B.
    Transactions of the Korean Institute of Electrical Engineers, 2021, 70 (06): : 878 - 886
  • [37] Comparison of a Synchronous Reference Frame Virtual Impedance-Based Autonomous Current Sharing Control with Conventional Droop Control for Parallel-Connected Inverters
    Guan, Yajuan
    Guerrero, Josep M.
    Zhao, Xin
    Vasquez, Juan C.
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [38] Analysis Of The Conflict Between Close-loop Control And The Current-Sharing Of AC Parallel Inverters And Parallel Control Strategy
    Zhi-zhong, Kan
    Chun-jiang, Zhang
    Bo, Zhang
    Xiao-huan, Wang
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 2275 - 2279
  • [39] Small-signal analysis and modeling of parallel inverters based on the droop control method in micro-grid
    Zhang, Xuan
    Liu, Jinjun
    You, Zhiyuan
    Zhou, Linyuan
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 4580 - 4586
  • [40] Consensus-Based Improved Droop Control for Suppressing Circulating Current Using Adaptive Virtual Impedance in Microgrids
    Kim, Sunghyok
    Zhang, Huaguang
    Sun, Qiuye
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 4473 - 4478