A study on quantitative assessment of osteoporosis based on texture analysis

被引:0
|
作者
Yang, X. [1 ]
Zhang, D. [1 ]
Jiang, D. [1 ]
机构
[1] Institute of Biomedical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A quantitative assessment on osteoporosis by using texture analysis has been developed on the basis of coherence mapping, two-dimensional power spectral estimation with modulated transfer function correction and fractal features analysis on trabecular pattern of bone X-ray images. Three objective features of trabecular pattern are selected to form a feature set that can be used in automatic classification for two grades of bone:normal bone and the bone with a medium degree of osteoporosis. This set of features is extracted from each of 16 sample bone X-ray images. With the use of Euclidean norm in the feature space, a center of cluster of each grade of bone is defined as the prototype. For each bone X-ray image, the distance from its features to the two prototypes in feature space is computed to provide an objective judgement on the degree of osteoporosis. The machine classification of 10 bone X-ray images based on the developed prototype is given, and the result indicates that the proposed method is potntially applicable to the objective diagnosis of osteoporosis.
引用
收藏
页码:403 / 407
相关论文
共 50 条
  • [21] On the entropy to texture index relationship in quantitative texture analysis
    Hielscher, R.
    Schaeben, H.
    Chateigner, D.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2007, 40 : 371 - 375
  • [22] Evaluation of changes in PET-based texture features for quantitative response assessment
    Lin, Christie
    Harmon, Stephanie
    Eickhoff, Jens
    Perlman, Scott
    Liu, Glenn
    Jeraj, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [23] Morphological texture assessment of oral bone as a screening tool for osteoporosis
    Analoui, M
    Eggertsson, H
    Eckert, G
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1226 - 1233
  • [24] Semi-quantitative Evaluation of Osteoporosis Based on Photoacoustic Signal Analysis
    Zhou, Xue
    Zhan, Hongchen
    Yuan, Jie
    Peng, Chenglei
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 126 : 43 - 43
  • [25] The utility of texture analysis based on quantitative synthetic magnetic resonance imaging in nasopharyngeal carcinoma: a preliminary study
    Yang, Fan
    Li, Yujie
    Li, Xiaolu
    Yu, Xiaoduo
    Zhao, Yanfeng
    Li, Lin
    Xie, Lizhi
    Lin, Meng
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [26] The utility of texture analysis based on quantitative synthetic magnetic resonance imaging in nasopharyngeal carcinoma: a preliminary study
    Fan Yang
    Yujie Li
    Xiaolu Li
    Xiaoduo Yu
    Yanfeng Zhao
    Lin Li
    Lizhi Xie
    Meng Lin
    BMC Medical Imaging, 23
  • [27] BEARTEX: a Windows-based program system for quantitative texture analysis
    Wenk, HR
    Matthies, S
    Donovan, J
    Chateigner, D
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1998, 31 : 262 - 269
  • [28] Bone texture analysis from plain radiographs: Influence of ageing an study in osteoporosis.
    Cortet, B
    Colin, D
    Dubois, P
    Duquesnoy, B
    Delcambre, B
    Marchandise, X
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 : T705 - T705
  • [29] QUANTITATIVE ANALYSIS OF OSTEOPOROSIS IN CORTICAL BONE
    ATKINSON, PJ
    NATURE, 1964, 201 (491) : 373 - &
  • [30] Quantitative calcium-based assessment of osteoporosis in dual-layer spectral CT
    Do, T. D.
    Rahn, S.
    Melzig, C.
    Heussel, C. P.
    Stiller, W.
    Kauczor, H. U.
    Weber, T. F.
    Skornitzke, S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 178