Bone collision detection method for robot assisted fracture reduction based on force curve slope

被引:0
|
作者
Cai, Chenxu [1 ,2 ]
Sun, Congyu [1 ,2 ]
Song, Yixuan [1 ,2 ]
Lv, Qinjing [1 ,2 ]
Bi, Jianping [3 ]
Zhang, Qinhe [1 ,2 ]
机构
[1] [1,Cai, Chenxu
[2] 1,Sun, Congyu
[3] 1,Song, Yixuan
[4] 1,Lv, Qinjing
[5] Bi, Jianping
[6] 1,Zhang, Qinhe
来源
Zhang, Qinhe (zhangqh@sdu.edu.cn) | 1600年 / Elsevier Ireland Ltd卷 / 209期
基金
中国国家自然科学基金;
关键词
Viscoelasticity - Fracture - Bone - Curve fitting;
D O I
暂无
中图分类号
学科分类号
摘要
Background and objective: The application of robot technology in fracture reduction ensures the minimal invasiveness and accurate operation process. Most of the existing robot assisted fracture reduction systems don't have the function of bone collision detection, which is very important for system safety. In view of the deficiencies in the research of this field, a broken bone collision detection method based on the slope ratio of force curve was proposed in this paper, which could realize the real-time detection. Methods: In order to analyze the factors influencing the slope of force curve, a collision mechanical model based on three-element viscoelastic model was established. The effects of four factors on the slope ratio of the force curve were studied based on the mechanical model. The proposed collision detection model was analyzed in detail. By drawing slope ratio curves under various experimental conditions, the universality of the collision detection model was proved; by comparative simulation, the differences between the slope ratio curves before and after optimization were analyzed. The factors that affect the performance of the detection model were also analyzed. Results: The results of collision experiments show that the increase of moving speed of distal bone and soft tissue mass reduces the slope ratio, while the increase of collision angle increases the slope ratio. In the verification experiment, the minimum main peak of KRopt curve is 14.16 and the maximum is 220.7, the maximum interference value before the peak is 6.1. When the detection threshold is 10, the model can detect the collision state of the broken bone. It is also proved that after optimization, the model can effectively filter out invalid waveforms and reduce the occurrence of false detections. When a=5 and b=40, the detection model has sufficient stability and a low detection time delay. Conclusion: This research developed a broken bone collision detection method based on the slope ratio of the force curve. After optimization, the method has good adaptability under a variety of experimental conditions. The collision of broken bones can be judged by setting an appropriate detection threshold. The application of this method in the robot fracture reduction system will improve the safety of the system. © 2021
引用
收藏
相关论文
共 50 条
  • [11] Safety Strategy of Fracture Reduction Robot Based on the Envelope Error of Reduction Path and Improved Artificial Force Field Method
    Lei J.
    Wang Y.
    Cheng L.
    Hu L.
    Wang T.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2020, 56 (01): : 9 - 19
  • [12] Six-dimensional constraints and force feedback for robot-assisted teleoperated fracture reduction
    Lei, Jingtao
    Song, Guangqing
    ROBOTICA, 2024, 42 (07) : 2328 - 2344
  • [13] Remote Control Method With Force Assist Based on Time to Collision for Mobile Robot
    Masaki, Ryo
    Motoi, Naoki
    IEEE OPEN JOURNAL OF THE INDUSTRIAL ELECTRONICS SOCIETY, 2020, 1 (01): : 157 - 165
  • [14] Collision avoidance method of humanoid robot with arm force
    Ohashi, E
    Aiko, T
    Tsuji, T
    Ohnishi, K
    2004 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), VOLS. 1- 3, 2004, : 1057 - 1062
  • [15] Collision avoidance method of humanoid robot with arm force
    Ohashi, Eijiro
    Aiko, Takahiro
    Tsuji, Toshiaki
    Nishi, Hiroaki
    Ohnishi, Kouhei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (03) : 1632 - 1641
  • [16] A method of sensorless collision detection based on motor current for robot manipulator
    Ma, Linjie
    Dong, Longlei
    Han, Yi
    Yan, Jian
    Zhou, Jiaming
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2020, 64 (1-4) : 237 - 244
  • [17] Force control of a single-link flexible robot based on a collision detection mechanism
    Garcia, A
    Feliu, V
    IEE PROCEEDINGS-CONTROL THEORY AND APPLICATIONS, 2000, 147 (06): : 588 - 595
  • [18] A Robot Assisted Hip Fracture Reduction with a Navigation System
    Joung, Sanghyun
    Kamon, Hirokazu
    Liao, Hongen
    Iwaki, Junichiro
    Nakazawa, Touji
    Mitsuishi, Mamoru
    Nakajima, Yoshikazu
    Koyama, Tsuyoshi
    Sugano, Nobuhiko
    Maeda, Yuki
    Bessho, Masahiko
    Ohashi, Satoru
    Matsumoto, Takuya
    Ohnihsi, Isao
    Sakuma, Ichiro
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 501 - 508
  • [19] Collision detection for robot force/position hybrid control based on fast dynamics identification
    Zhang C.
    Wang Y.
    Mu C.
    Li J.
    Liu Z.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (06): : 161 - 171
  • [20] Autonomous Path Planning With Muscle Force Optimization for Robot-Assisted Pelvic Fracture Closed Reduction
    Chen, Yuan
    Pan, Ming-Zhang
    Li, Zhen
    Deng, Ya-Wen
    Liao, Xiao-Lan
    Bian, Gui-Bin
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2023, 5 (02): : 253 - 264