Simultaneous Determination of Nine Phenolic Antioxidants in Vegetable Oil by Pass-through Solid Phase Extraction Cleanup and Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry

被引:1
|
作者
Zhang Y. [1 ]
Zhao H. [1 ]
Sun S. [1 ]
Xu X. [2 ]
Zheng W. [1 ]
Xue X. [1 ]
Wang M. [1 ]
Liu Y. [1 ]
Zhu J. [1 ]
机构
[1] Shandong Research Center of Engineering and Technology for Quality Control of Food for Special Medical Purposes, Shandong Research Center of Engineering and Technology for Safety Inspection of Food and Drug, Shandong Institute for Food and Drug Control, Ji
[2] Yulin-Jinan Gas Pipeline Division of Nature Gas Company, SINOPEC Tianranqi Company, Jinan
来源
Shipin Kexue/Food Science | 2021年 / 42卷 / 10期
关键词
Antioxidants; Pass-through solid phase extraction cleanup; Ultra-high performance liquid chromatography-tandem mass spectrometry; Vegetable oil;
D O I
10.7506/spkx1002-6630-20200416-207
中图分类号
学科分类号
摘要
A method for the determination of nine phenolic antioxidants in vegetable oil by pass-through solid phase extraction (SPE) cleanup combined with ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS) was established. The antioxidants in samples were extracted with 0.5% formic acid-acetonitrile (V/V), purified by a pass-through SPE procedure on an Oasis® PRiME HLB column. The chromatographic separation was carried out using a C18 column with gradient elution using a mobile phase consisting of acetonitrile and water. The target compounds were detected by triple quadrupole mass spectrometry with electrospray ionization (ESI) under the multiple reaction monitoring (MRM) mode. The calibration curves of the nine antioxidants showed good linearity in their own ranges with correlation coefficients of higher than 0.994. The average recoveries ranged from 82.2% to 115.2% at three spiking levels with relative standard deviation (RSD) of less than 9.3%. The limits of detection (LODs) of the analytes were in the range of 0.003-0.02 mg/kg. The limits of quantitation (LOQs) of the analytes were in the range of 0.01-0.05 mg/kg. This rapid and sensitive method is suitable for the detection of antioxidants in vegetable oil. © 2021, China Food Publishing Company. All right reserved.
引用
收藏
页码:322 / 329
页数:7
相关论文
共 17 条
  • [11] MARCELLA C, CHADIN K, JALAL T A, Et al., Direct analysis of synthetic phenolic antioxidants, and fatty acid methyl ester stability in biodiesel by liquid chromatography and high-resolution mass spectrometry, Chromatographia, 82, 1, pp. 271-278, (2019)
  • [12] TSUJI S, NAKANO M, TERADA H, Et al., Determination and confirmation of five phenolic antioxidants in foods by LC/MS and GC/MS, Shokuhinseigaku Zasshi, 46, 3, pp. 63-71, (2005)
  • [13] 11, (2014)
  • [14] ZHANG Y X, XUE X, SU S F, Et al., A multi-class, multi-residue method for detection of veterinary drugs in multiple meat using a pass-through cleanup spe technique and UPLC-MS/MS analysis, Food Analytical Methods, 11, pp. 2865-2884, (2018)
  • [15] (2016)
  • [16] 1
  • [17] (2014)