Three-dimensional magnetic and abundance mapping of the cool Ap star HD24712 II. Two-dimensional magnetic Doppler imaging in all four Stokes parameters

被引:0
|
作者
20150400443990
机构
[1] Rusomarov, N.
[2] Kochukhov, O.
[3] Ryabchikova, T.
[4] Piskunov, N.
来源
| 1600年 / EDP Sciences卷 / 573期
关键词
Magnetic fields;
D O I
暂无
中图分类号
学科分类号
摘要
Aims. We present a magnetic Doppler imaging study from all Stokes parameters of the cool, chemically peculiar star HD24712. This is the very first such analysis performed at a resolving power exceeding 105. Methods. The analysis is performed on the basis of phase-resolved observations of line profiles in all four Stokes parameters obtained with the HARPSpol instrument attached at the 3.6 m ESO telescope. We used the magnetic Doppler imaging code invers10, which allowed us to derive the magnetic field geometry and surface chemical abundance distributions simultaneously. Results. We report magnetic maps of HD24712 recovered from a selection of Fe I, Fe II, Nd III, and Na I lines with strong polarization signals in all Stokes parameters. Our magnetic maps successfully reproduce most of the details available from our observation data. We used these magnetic field maps to produce abundance distribution map of Ca. This new analysis shows that the surface magnetic field of HD24712 has a dominant dipolar component with a weak contribution from higher-order harmonics. The surface abundance distributions of Fe and Ca show enhancements near the magnetic equator with an underabundant patch at the visible (positive) magnetic pole; Nd is highly abundant around the positive magnetic pole. The Na abundance map shows a high overabundance around the negative magnetic pole. Conclusions. Based on our investigation and similar recent magnetic mapping studies that used four Stokes parameters, we present tentative evidence for the hypothesis that Ap stars with dipole-like fields are older than stars with magnetic fields that have more small-scale structures. We find that our abundance maps are inconsistent with recent theoretical calculations of atomic diffusion in presence of magnetic fields. © ESO 2015.
引用
收藏
相关论文
共 50 条
  • [1] Three-dimensional magnetic and abundance mapping of the cool Ap star HD 24712 II. Two-dimensional magnetic Doppler imaging in all four Stokes parameters
    Rusomarov, N.
    Kochukhov, O.
    Ryabchikova, T.
    Piskunov, N.
    ASTRONOMY & ASTROPHYSICS, 2015, 573
  • [2] Three-dimensional magnetic and abundance mapping of the cool Ap star HD 24712 I. Spectropolarimetric observations in all four Stokes parameters
    Rusomarov, N.
    Kochukhov, O.
    Piskunov, N.
    Jeffers, S. V.
    Johns-Krull, C. M.
    Keller, C. U.
    Makaganiuk, V.
    Rodenhuis, M.
    Snik, F.
    Stempels, H. C.
    Valenti, J. A.
    ASTRONOMY & ASTROPHYSICS, 2013, 558
  • [3] Three-dimensional magnetic resonance imaging technique for myocardial-delayed hyperenhancement: A comparison with the two-dimensional technique
    Tatli, S
    Zou, KH
    Fruitman, M
    Reynolds, HG
    Foo, T
    Kwong, R
    Yucel, EK
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) : 378 - 382
  • [4] Rotator cuff tear shape characterization: a comparison of two-dimensional imaging and three-dimensional magnetic resonance reconstructions
    Gyftopoulos, Soterios
    Beltran, Luis S.
    Gibbs, Kevin
    Jazrawi, Laith
    Berman, Phillip
    Babb, James
    Meislin, Robert
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (01) : 22 - 30
  • [5] Field-induced slow magnetic relaxation in two-dimensional and three-dimensional Co(ii) coordination polymers
    Ma, Deyun
    Peng, Guo
    Zhang, Ying-Ying
    Li, Bo
    DALTON TRANSACTIONS, 2019, 48 (41) : 15529 - 15536
  • [6] Agreement of two-dimensional and three-dimensional transvaginal ultrasound with magnetic resonance imaging in assessment of parametrial infiltration in cervical cancer
    Chiappa, V.
    Di Legge, A.
    Valentini, A. L.
    Gui, B.
    Micco, M.
    Ludovisi, M.
    Giansiracusa, C.
    Testa, A. C.
    Valentin, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (04) : 459 - 469
  • [7] Quantitative assessment of carotid artery atherosclerosis by three-dimensional magnetic resonance and two-dimensional ultrasound imaging: a comparison study
    Qiao, Huiyu
    Cai, Ying
    Huang, Manwei
    Liu, Yang
    Qiang, Zhang
    Huang, Lingyun
    Chen, Huijun
    Yuan, Chun
    Zhao, Xihai
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (05) : 1021 - 1032
  • [8] Accuracy of Three-Dimensional Versus Two-Dimensional Echocardiography for Quantification of Aortic Regurgitation and Validation by Three-Dimensional Three-Directional Velocity-Encoded Magnetic Resonance Imaging
    Ewe, See Hooi
    Delgado, Victoria
    van der Geest, Rob
    Westenberg, Jos J. M.
    Haeck, Marlieke L. A.
    Witkowski, Tomasz G.
    Auger, Dominique
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Sieders, Allard
    Siebelink, Hans-Marc J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (04): : 560 - 566
  • [9] Significance of three-dimensional turbo spin-echo magnetic resonance imaging with semiquantitative assessment of knee osteoarthritis: correlation to two-dimensional routine magnetic resonance imaging
    Hashem, Aya Mohamed Bassam
    El-Liethy, Nevien Ezzat Mohamed
    El-Din, Osama Mohamed Helmy Noor
    Mahmoud, Mostafa Ezzat
    Hashem, Lamiaa Mohamed Bassam
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [10] Value of real time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy: Comparison with two-dimensional echocardiography and magnetic resonance imaging
    Bicudo, Leticia S.
    Tsutsui, Jeane M.
    Shiozaki, Afonso
    Rochitte, Carlos E.
    Arteaga, Edmundo
    Mady, Charles
    Ramires, Jose A. F.
    Mathias, Wilson, Jr.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (07): : 717 - 726