Proton-spinlocking and T1ρ-weighted MR imaging at 1.5 T

被引:0
|
作者
Sammet, Steffen [1 ]
Bock, Michael [1 ]
Streckenbach, Markus [1 ]
Bachert, Peter [1 ]
机构
[1] Abt. Biophys./Med. Strahlenphysik, Forschungsschwerpunkt Radiol. Diagn., Deutsches Krebsforschungszentrum, Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
来源
Zeitschrift fur Medizinische Physik | 2002年 / 12卷 / 01期
关键词
Brain tissue - Contrast - MR imaging - Oscillating fields - Rotating frame - Spin lattice relaxation time - Spin-lattice relaxation time in the rotating frame T1ρ - Spin-locking - Spinlock - Time-constants;
D O I
10.1016/S0939-3889(15)70539-8
中图分类号
学科分类号
摘要
引用
收藏
页码:16 / 23
相关论文
共 50 条
  • [21] T1 Hyperintense Renal Lesions: Characterization with Diffusion-weighted MR Imaging versus Contrast-enhanced MR Imaging
    Kim, Sooah
    Jain, Monica
    Harris, Andrew B.
    Lee, Vivian S.
    Babb, James S.
    Sigmund, Eric E.
    Rueff, Laura E.
    Taouli, Bachir
    RADIOLOGY, 2009, 251 (03) : 796 - 807
  • [22] MALIGNANT LESIONS OF THE LIVER IDENTIFIED ON T1-WEIGHTED BUT NOT T2-WEIGHTED MR-IMAGES AT 1.5 T
    SEMELKA, RC
    BAGLEY, AS
    BROWN, ED
    KROEKER, MA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 315 - 318
  • [23] Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging
    Muertz, P.
    Kaschner, M.
    Lakghomi, A.
    Gieseke, J.
    Willinek, W. A.
    Schild, H. H.
    Thomas, D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (04) : 696 - 702
  • [24] Evaluation of liver fibrosis with T1 rho MR imaging
    Wang, Yi-Xiang J.
    Yuan, Jing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (03) : 152 - 155
  • [25] PROSTATIC DISORDERS - MR IMAGING AT 1.5 T
    PHILLIPS, ME
    KRESSEL, HY
    SPRITZER, CE
    ARGER, PH
    WEIN, AJ
    MARINELLI, D
    AXEL, L
    GEFTER, WB
    POLLACK, HM
    RADIOLOGY, 1987, 164 (02) : 386 - 392
  • [26] MR IMAGING OF THE LARYNX AT 1.5-T
    SAKAI, F
    GAMSU, G
    DILLON, WP
    LYNCH, DA
    GILBERT, TJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (01) : 60 - 71
  • [27] TESTES AND SCROTUM - MR IMAGING AT 1.5 T
    SEIDENWURM, D
    SMATHERS, RL
    LO, RK
    CARROL, CL
    BASSETT, J
    HOFFMAN, AR
    RADIOLOGY, 1987, 164 (02) : 393 - 398
  • [28] Imaging cortical demyelination using T1/T2-weighted ratio
    Nakamura, K.
    Chen, J. T.
    Fox, R. J.
    Ontaneda, D.
    Trapp, B. D.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 : 526 - 526
  • [29] Prostate diffusion-weighted imaging (DWI) in MR-guided radiotherapy: Reproducibility assessment on 1.5 T MR-Linac and 1.5 T MR-simulator
    Wong, Oi Lei
    Yuan, Jing
    Poon, Darren M. C.
    Chiu, Sin Ting
    Yang, Bin
    Chiu, George
    Yu, Siu Ki
    Cheung, Kin Yin
    MAGNETIC RESONANCE IMAGING, 2024, 111 : 47 - 56
  • [30] Silent 3D MR sequence for quantitative and multicontrast T1 and proton density imaging
    Liu, Xin
    Gomez, Pedro A.
    Solana, Ana Beatriz
    Wiesinger, Florian
    Menzel, Marion, I
    Menze, Bjoern H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18):