A novel adaptive-fuzzy hysteresis current controller-based active power line conditioners for power quality enhancement

被引:2
|
作者
机构
[1] Karuppanan, P.
[2] Mahapatra, Kamala Kanta
来源
Karuppanan, P. (karuppanan1982@gmail.com) | 1600年 / Inderscience Enterprises Ltd.卷 / 05期
关键词
Reactive power - Hysteresis - Extraction - Active filters - Electric current control - Fuzzy filters - Power quality - Controllers - Electric inverters;
D O I
10.1504/IJPELEC.2013.057049
中图分类号
学科分类号
摘要
This paper presents a three-phase shunt active power line conditioner (APLC) for harmonics and reactive power compensation to enhance the power quality. The compensation process is based on sinusoidal extraction control method, which consists of positive-sequence voltage detector to regulate the distorted supply voltage and instantaneous real-power for fundamental component extraction from the distorted line current. The voltage source inverter (VSI)-based active filter switching pulses is generated through adaptive fuzzy hysteresis current controller (HCC). For the adaptive-fuzzy-HCC, bandwidth is calculated without precise knowledge of the APLC parameters (interface inductor and DC-link voltage), the hysteresis band value can be implemented with a fuzzy logic. A comparative assessment of fixed-HCC, adaptive-HCC and adaptive-fuzzy-HCC is carried out. The shunt APLC system is validated through extensive simulation under distorted supply voltage and non-linear load conditions. Copyright © 2013 Inderscience Enterprises Ltd.
引用
收藏
页码:3 / 4
相关论文
共 50 条
  • [21] A novel hysteresis current controller for active power filter with constant switching frequency
    Zeng, J
    Jiao, LW
    Ni, YX
    Chen, SS
    Zhang, BL
    Shen, CM
    Wu, FF
    IPEMC 2000: THIRD INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, PROCEEDINGS, 2000, : 692 - 697
  • [22] Adaptive fuzzy controlled hybrid shunt active power filter for power quality enhancement
    Mishra, Alok K.
    Ray, Prakash K.
    Mallick, Ranjan K.
    Mohanty, Asit
    Das, Soumya R.
    NEURAL COMPUTING & APPLICATIONS, 2021, 33 (05): : 1435 - 1452
  • [23] Adaptive fuzzy controlled hybrid shunt active power filter for power quality enhancement
    Alok K. Mishra
    Prakash K. Ray
    Ranjan K. Mallick
    Asit Mohanty
    Soumya R. Das
    Neural Computing and Applications, 2021, 33 : 1435 - 1452
  • [24] Interval type-2 fuzzy controller-based power quality enhancement in HSES grid-Integrated scheme
    Vanaja, N.
    Kumar, N. Senthil
    AUTOMATIKA, 2023, 64 (03) : 577 - 592
  • [25] ADALINE Harmonics Extraction Algorithm applied to a Shunt Active Power Filter based on an Adaptive Fuzzy Hysteresis current control and a fuzzy DC voltage controller
    Khenfar, Noureddine
    Semmah, Abdelhafid
    Kadem, Mohamed
    PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (05): : 116 - 121
  • [26] A Modified Fuzzy Hysteresis Controller For Shunt Active Power Filter
    Koya, Shameer A.
    Alsumiri, Mohammed
    2018 RENEWABLE ENERGIES, POWER SYSTEMS & GREEN INCLUSIVE ECONOMY (REPS-GIE), 2018,
  • [27] A Novel Hysteresis Current Control Strategy with Fuzzy Bandwidth for Active Power Filter
    Liu, Xinyang
    Wang, Jie
    Yao, Gang
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2012, 120 (04) : 3 - 8
  • [28] Photovoltaic Interfaced Shunt Active Power Filter Under Online-Varying Parameters Based On Fuzzy Logic Controller And Adaptive Hysteresis Band Current Controller
    Azzam-Jai, Asmae
    Ouassaid, Mohammed
    2019 THIRD INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING IN DATA SCIENCES (ICDS 2019), 2019,
  • [29] SVM based hysteresis current controller for a three phase active power filter
    Ling, LP
    Azli, NA
    NATIONAL POWER & ENERGY CONFERENCE: PECON 2004, PROCEEDINGS, 2004, : 132 - 136
  • [30] An adaptive hysteresis band current controller for hybrid power filter
    Dalvand, H.
    Moghani, J. S.
    Talebi, N.
    2006 INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS, VOLS 1 AND 2, 2006, : 613 - +