Motion correction of parametric fMRI data from multi-slice single-shot multi-echo acquisitions

被引:13
|
作者
机构
[1] [1,Speck, O.
[2] Hennig, J.
关键词
D O I
10.1002/mrm.1291
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Investigation of heart motion with multi-slice cardiac CT for attenuation correction of PET emission data
    Vass, M
    Sasaki, K
    Pan, T
    RADIOLOGY, 2002, 225 : 520 - 520
  • [22] Quantitative Deconvolution of fMRI Data with Multi-echo Sparse Paradigm Free Mapping
    Caballero-Gaudes, Cesar
    Moia, Stefano
    Bandettini, Peter A.
    Gonzalez-Castillo, Javier
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, PT III, 2018, 11072 : 311 - 319
  • [23] BOLD Contrast and Noise Characteristics of Densely Sampled Multi-Echo fMRI Data
    Chiew, Mark
    Graham, Simon J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (09) : 1691 - 1703
  • [24] WHOCARES: WHOle-brain CArdiac signal REgression from highly accelerated simultaneous multi-Slice fMRI acquisitions
    Colenbier, Nigel
    Marino, Marco
    Arcara, Giorgio
    Frederick, Blaise
    Pellegrino, Giovanni
    Marinazzo, Daniele
    Ferrazzi, Giulio
    JOURNAL OF NEURAL ENGINEERING, 2022, 19 (05)
  • [25] Estimation and removal of physiological noise from undersampled multi-slice fMRI data in image space
    Wang, S. J.
    Luo, L. M.
    Liang, X. Y.
    Gui, Z. G.
    Chen, C. X.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1371 - 1373
  • [26] Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla
    Wang, JJ
    Li, L
    Roc, AC
    Alsop, DC
    Tang, K
    Butler, NS
    Schnall, MD
    Detre, JA
    MAGNETIC RESONANCE IMAGING, 2004, 22 (01) : 1 - 7
  • [27] Constrained coupled CPD of complex-valued multi-slice multi-subject fMRI data
    Kuang, Li-Dan
    Zhu, Hao
    Long, Lei
    Tang, Ting
    Gui, Yan
    Zhang, Jin
    SIGNAL PROCESSING, 2025, 234
  • [28] Single-shot multi-parametric mapping based on multiple overlapping-echo detachment (MOLED) imaging
    Ma, Lingceng
    Wu, Jian
    Yang, Qinqin
    Zhou, Zihan
    He, Hongjian
    Bao, Jianfeng
    Bao, Lijun
    Wang, Xiaoyin
    Zhang, Pujie
    Zhong, Jianhui
    Cai, Congbo
    Cai, Shuhui
    Chen, Zhong
    NEUROIMAGE, 2022, 263
  • [29] Extraction of Task-Related Activation From Multi-Echo BOLD fMRI
    Buur, Pieter F.
    Norris, David G.
    Hesse, Christian W.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2008, 2 (06) : 954 - 964
  • [30] Comparison of simultaneous multi-slice readout-segmented EPI and conventional single-shot EPI for diffusion tensor imaging of the ulnar nerve
    Ho, Michael
    Becker, Anton
    Ulbrich, Erika
    Manoliu, Andrei
    Kuhn, Felix P.
    Eberhard, Matthias
    Filli, Lukas
    HELIYON, 2018, 4 (10):