Fault current study of inverter interfaced distributed generators

被引:12
|
作者
Kong, Xiangping [1 ]
Zhang, Zhe [2 ]
Yin, Xianggen [2 ]
机构
[1] State Grid Jiangsu Electric Power Company Research Institute, Nanjing, Jiangsu Province, China
[2] College of Electrical and Electronic Engineering, HUST, China
关键词
Dynamic response;
D O I
10.1080/21563306.2015.11461420
中图分类号
学科分类号
摘要
The fault current characteristics of inverter interfaced distributed generators (IIDGs) are very different from those of traditional synchronous generator. Prior to the fault current analysis of IIDG, a control strategy for low voltage ride-through (LVRT) of IIDG is proposed to meet the grid code. Then the fault current characteristics of IIDG are analyzed based on the study of dynamic responses of the inverter under conditions of symmetric faults and asymmetric faults. Meanwhile, the analytical expressions of the fault current of IIDG are obtained. Finally, the fault current characteristics of IIDG are validated with simulation studies.
引用
收藏
页码:6 / 26
相关论文
共 50 条
  • [41] A Virtual Multi-Terminal Current Differential Protection Scheme for Distribution Networks With Inverter-Interfaced Distributed Generators
    Han, Bowen
    Li, Haifeng
    Wang, Gang
    Zeng, Dehui
    Liang, Yuansheng
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (05) : 5418 - 5431
  • [42] Fault Current Negative Contribution Method for Inverter-Based Distributed Generators Under Grid Unbalanced Fault
    Liu, Xubin
    IEEE ACCESS, 2020, 8 : 220807 - 220815
  • [43] Active protection scheme based on high-frequency current for distribution networks with inverter-interfaced distributed generators
    Li, Haifeng
    Liang, Huamin
    Wang, Zhidong
    Zhang, Zhenggang
    Liang, Yuansheng
    IET RENEWABLE POWER GENERATION, 2024, 18 (14) : 2737 - 2750
  • [44] Novel Pilot Protection Scheme for Distribution Networks with Inverter-interfaced Distributed Generators
    Han B.
    Wang G.
    Li H.
    Zeng D.
    Li, Haifeng (lihf@scut.edu.cn), 1600, Science Press (43): : 3453 - 3462
  • [45] Impact of Inverter Interfaced Generators on Distance Protection
    Feng, Yulei
    Zhang, Zhe
    Lai, Qinghua
    Yin, Xianggen
    Liu, Huiyuan
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 512 - 515
  • [46] Transient Stability Mechanism and Judgment for Inverter Interfaced Distributed Generators Connected with Public Grids
    Yu M.
    Huang W.
    Tai N.
    Ma Z.
    Lin Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (10): : 2596 - 2610
  • [47] Detection of Fault using Local Measurements at Inverter Interfaced Distributed Energy Resources
    Alexopoulos, Theodoros
    Biswal, Milan
    Brahma, Sukumar M.
    El Khatib, Mohamed
    2017 IEEE MANCHESTER POWERTECH, 2017,
  • [48] Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators
    Chakraborty, Soham
    Das, Sarasij
    Singh, Utkarsh
    Lekic, Aleksandra
    Singh, Ravi
    Chavez, Jose de Jesus
    Popov, Marjan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2025, 40 (02) : 1040 - 1053
  • [49] Performance of inverter interfaced distributed generation
    Wall, SR
    2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 945 - 950
  • [50] Optimal Scheduling of Active/Reactive Power for Inverter Interfaced Distributed Generators during Voltage Sags
    Sun, Kai
    Zhang, Jiamei
    Li, Canbing
    Feng, Kan
    Sun, Pei
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 565 - 570