Fault current study of inverter interfaced distributed generators

被引:12
|
作者
Kong, Xiangping [1 ]
Zhang, Zhe [2 ]
Yin, Xianggen [2 ]
机构
[1] State Grid Jiangsu Electric Power Company Research Institute, Nanjing, Jiangsu Province, China
[2] College of Electrical and Electronic Engineering, HUST, China
关键词
Dynamic response;
D O I
10.1080/21563306.2015.11461420
中图分类号
学科分类号
摘要
The fault current characteristics of inverter interfaced distributed generators (IIDGs) are very different from those of traditional synchronous generator. Prior to the fault current analysis of IIDG, a control strategy for low voltage ride-through (LVRT) of IIDG is proposed to meet the grid code. Then the fault current characteristics of IIDG are analyzed based on the study of dynamic responses of the inverter under conditions of symmetric faults and asymmetric faults. Meanwhile, the analytical expressions of the fault current of IIDG are obtained. Finally, the fault current characteristics of IIDG are validated with simulation studies.
引用
收藏
页码:6 / 26
相关论文
共 50 条
  • [1] A fast fault current calculation method for distribution networks connected with inverter interfaced distributed generators
    Li, Yingliang
    Wang, Deming
    METHODSX, 2021, 8
  • [2] Fault Location Identification in Power Islands with Inverter Interfaced Distributed Generators
    Chhetija, Deepika
    Rather, Zakir Hussain
    Doolla, Suryanarayana
    IEEE Transactions on Instrumentation and Measurement, 2024, 73
  • [3] Asymmetrical fault analysis on distribution feeders with inverter interfaced distributed generators
    Li, Yingliang
    Wang, Deming
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 125
  • [4] Flexible fault current contribution with inverter interfaced distributed generation
    Wijnhoven, Thomas
    Deconinck, Geert
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [5] Analysis on Asymmetric Fault Current of Inverter Interfaced Distributed Generator
    Chang, Zhongxue
    Song, Guobing
    Wang, Xiaobo
    Guo, Shanghua
    Zhang, Wei
    Jin, Xinfu
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [6] Fault detection and classification scheme for power islands with inverter interfaced distributed generators
    Chhetija, Deepika
    Khadka, Dhiraj
    Gupta, Yusuf
    Rather, Zakir Hussain
    Doolla, Suryanarayana
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 233
  • [7] Analysis of Fault Response of Inverter-Interfaced Distributed Generators in Sequence Networks
    Mahamedi, Behnam
    Zhu, Jian Guo
    Eskandari, Mohsen
    Li, Li
    Mehrizi-Sani, Ali
    2018 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2018,
  • [8] Fault Analysis of Inverter-Interfaced Distributed Generators With Different Control Schemes
    Shuai, Zhikang
    Shen, Chao
    Yin, Xin
    Liu, Xuan
    Shen, Z. John
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (03) : 1223 - 1235
  • [9] Fault response of inverter interfaced distributed generators in grid-connected applications
    Plet, Cornelis A.
    Green, Timothy C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 106 : 21 - 28
  • [10] Fault Models of Inverter-Interfaced Distributed Generators: Experimental Verification and Application to Fault Analysis
    Plet, Cornelis A.
    Brucoli, Maria
    McDonald, John D. F.
    Green, Timothy C.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,