Transmission line pilot protection based on frequency-domain model identification of distributed parameter

被引:0
|
作者
机构
[1] Suonan, Jiale
[2] Wang, Chenqing
[3] Kang, Xiaoning
[4] Ma, Chao
[5] Liu, Xin
来源
Suonan, J. (suonan@263.net) | 1600年 / Chinese Society for Electrical Engineering卷 / 33期
关键词
Network topology - Matrix algebra - Frequency domain analysis - Electric fault currents - Parameter estimation;
D O I
暂无
中图分类号
学科分类号
摘要
To eliminate the capacitive current's influence on line protection of long-distance and high-voltage transmission lines, this paper proposed a novel transmission line protection scheme based on model identification method and on the point that matrix pencil algorithm can extract the characteristic frequencies of the transmission line reliably. By studying the fault network topology of distributed parameter lines, the frequency-domain models of external and internal fault states were built. The fault model for external fault states is a distributed capacitive model, while the fault model for internal fault state is an equivalent system impedance model. The two kinds of unbalanced currents were defined as two model errors to identify different fault models. When an external fault occurs, the fault data corresponds with the distributed capacitive model and its unbalanced current is smaller than that of the equivalent system impedance model. When an internal fault occurs, fault data corresponds with the equivalent system impedance model and its unbalanced current is smaller than that of the distributed capacitive model. Therefore, external and internal faults are distinguished. Theoretical analysis and simulation results show that the new principle can remove internal fault quickly and reliably, free from the influence of capacitive current and transition resistances. © 2013 Chin. Soc. for Elec. Eng.
引用
收藏
相关论文
共 50 条
  • [21] Transmission line pilot protection based on phase segregated model recognition
    Jiale, S.
    Cheng, Y.
    Guobing, S.
    Xiaoning, K.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2009, 3 (09) : 885 - 890
  • [22] Frequency Response Model of Regional Power Grid Based on Parameter Identification on Trip Process of Transmission Line
    Hao, Tao
    Tang, Yaohua
    Zhou, Xuzhan
    Wang, Hongwei
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 2406 - 2410
  • [23] STRUCTURAL PARAMETER-IDENTIFICATION IN THE FREQUENCY-DOMAIN - THE USE OF OVERDETERMINED SYSTEMS
    BRAUN, SG
    RAM, YM
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1987, 109 (02): : 120 - 123
  • [24] FREQUENCY-DOMAIN CONDITIONS FOR PARAMETER CONVERGENCE IN MULTIVARIABLE RECURSIVE-IDENTIFICATION
    DEMATHELIN, M
    BODSON, M
    AUTOMATICA, 1990, 26 (04) : 757 - 767
  • [25] A LINEAR, FREQUENCY-DOMAIN FILTER FOR PARAMETER-IDENTIFICATION OF VIBRATING STRUCTURES
    MOTTERSHEAD, JE
    LEES, AW
    STANWAY, R
    JOURNAL OF VIBRATION ACOUSTICS STRESS AND RELIABILITY IN DESIGN-TRANSACTIONS OF THE ASME, 1987, 109 (03): : 262 - 269
  • [26] FREQUENCY-DOMAIN IDENTIFICATION FOR UNDERGRADUATES
    HASSUL, M
    SHAHIAN, B
    IEEE TRANSACTIONS ON EDUCATION, 1992, 35 (04) : 368 - 375
  • [27] Online Transmission Line Impedance Parameter Identification for Distributed Generation
    Gai, Bao
    Pan, Zaiping
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [28] Experimental Research on Vibration Depression of Pump Truck Boom Based on Parameter Identification in Frequency-Domain
    Huang Y.
    Liu J.
    Hu Y.
    Fan J.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2021, 41 (06): : 1119 - 1123
  • [29] ROBUST FREQUENCY-DOMAIN IDENTIFICATION
    GOBERDHANSINGH, E
    WANG, L
    CLUETT, WR
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (08) : 1989 - 1999
  • [30] A fault location method for DC transmission line based on the distributed parameter model considering line parameter uncertainty
    Xia, Chengjun
    Yang, Mingjia
    Chi, Zibin
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 238