Experimental study on lighting shielding performance of ±500 kV HVDC transmission line

被引:0
|
作者
He, Heng-Xin [1 ]
He, Jun-Jia [1 ]
Jiang, Zheng-Long [2 ]
Wang, Cheng [2 ]
Ye, Hui-Sheng [2 ]
Wang, Xin-Xiu [2 ]
Bian, Kai [1 ]
Xie, Shi-Jun [1 ]
机构
[1] College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
[2] Hunan Electric Power Test and Research Institute, Changsha 410007, China
关键词
Lightning - Electric lines - HVDC power transmission - Failure analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Simulation experiment is one of the important techniques for the lightning shielding performance study of EHV/UHV transmission line. A simulation experiment was carried out in this paper for studying the impact of nominal field on the lightning shielding performance of HVDC transmission line, the test equivalency was verified in following aspects: the determination of test scale, the simulation of near field during the descend leader process and the simulation of nominal field in the vicinity of model lines. The exposure space of G4-40 is received both when the polar conductor is applied with DC voltage and without DC voltage. The residue upward streamer incepted from the surface of conductors which is fail to hit and the primary discharge can be observed at the same time. According to observed phenomenon, the influence mechanism of DC voltage was analyzed qualitatively, and the shielding failure rate of positive polar with DC voltage is 1.79 times of which without DC voltage. © 2009 Chin.Soc.for Elec.Eng.
引用
收藏
页码:20 / 26
相关论文
共 50 条
  • [41] Live-line work on the 500 KV transmission line with a silk jack ladder
    Chen Jiansheng Wuhan High Voltage Research Institute
    Electricity, 1991, (01) : 55 - 56
  • [42] BPA 500-KV TRANSMISSION-LINE AND SUBSTATION DESIGN
    STEVENS, RF
    DAVIES, IT
    MARJERRISON, MN
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (06): : 687 - +
  • [43] Fault analysis and modified measures of 500 kV compact transmission line
    Wang, Li-Ming
    Sun, Bao-Qiang
    Hou, Lei
    Fu, Guan-Jun
    Meng, Xiao-Bo
    Guan, Zhi-Cheng
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (09): : 2108 - 2113
  • [44] Design and operation of 500kV transmission line protection in China
    Wang Zhongyuan Dai Xuean Nanjing Automation Research Institute
    Electricity, 1990, (02) : 42 - 44
  • [45] Tests on the first 500kV compact transmission line in China
    Gong, XH
    Wang, HR
    Zhang, ZK
    Wang, JP
    Wang, J
    Yuan, YC
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 173 - 178
  • [46] 5005 ALLOY CONDUCTOR FOR VEPCO 500-KV TRANSMISSION LINE
    RAWLS, JA
    ADAMS, HW
    SMALLING, CA
    HONDALUS, B
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (06): : 573 - &
  • [47] CONSTRUCTION OF COMPACT 500 kV GAS INSULATED TRANSMISSION LINE.
    Uchida, Keiji
    Yamada, Kazuo
    Kazama, Yohji
    Itoi, Hiroshi
    Sasaki, Tatsuo
    Oka, Yohichiro
    Itaka, Kohshi
    Araki, Tomoo
    Kawai, Kohei
    Hara, Takushi
    Yoshimura, Fumihiko
    Sugiyama, Noriyuki
    Satoh, Norio
    Sumitomo Electric Technical Review, 1987, (26): : 242 - 251
  • [48] TRANSIENT VOLTAGES IN A TRANSFORMER CONNECTED TO A 500 KV TRANSMISSION-LINE
    INDULKAR, CS
    SAHA, SN
    KOTHARI, DP
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (09): : 2564 - 2570
  • [49] SURGE PROPAGATION ON JAPANESE 500 KV UNTRANSPOSED TRANSMISSION-LINE
    AMETANI, A
    HONAGA, Y
    OUCHI, Y
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1974, 121 (02): : 136 - 138
  • [50] The security precautions in the 500 kV transmission line protection upgrading and replacing
    Yao, Li-Na
    Liu, Hua
    Zhang, Bin
    Zhou, Ya-Hui
    Jia, Wei
    Zhang, Xin-Wang
    Zhang, Qiang
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (22): : 220 - 223