Experimental research on heat transfer performance of condenser used in 1 000 MW direct air-cooled generator unit

被引:0
|
作者
Zhang, Zhaoying [1 ]
Yang, Jianguo [1 ]
Zheng, Lijun [2 ]
机构
[1] Institute of Energy and Environment, Harbin Institute of Technology at Weihai, Weihai,Shangdong Province,264209, China
[2] Clean Environmental Protection Co., Ltd, Shenyang,Liaoning Province,110034, China
关键词
Wind speed - Fins (heat exchange) - Reynolds number - Tubes (components) - Atmospheric temperature - Air - Cooling systems - Heat transfer;
D O I
10.13334/j.0258-8013.pcsee.2014.20.010
中图分类号
学科分类号
摘要
引用
收藏
页码:3317 / 3323
相关论文
共 50 条
  • [21] Air side heat transfer characteristics of wavy-finned-tube in a forced draft direct air-cooled steam condenser
    Zhang, Zhaoying
    Yang, Jianguo
    Zhang, Haizhen
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 3 - 8
  • [22] Experimental Study on the Performance of Air-Cooled Condensing Unit in Groove
    Zhao, An-qiang
    Li, Qiong
    Meng, Qing-wei
    Meng, Qing-lin
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING (SEEE 2016), 2016,
  • [23] Flow and heat transfer characteristics of flow guiding device in air-cooled condenser cell
    Yang, Li-Jun
    Pu, Gang
    Du, Xiao-Ze
    Yang, Yong-Ping
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (06): : 1001 - 1004
  • [24] Influence mechanism on flow and heat transfer characteristics for air-cooled steam condenser cells
    Wei Feng He
    Yi Ping Dai
    Mao Qing Li
    Qing Zhong Ma
    Heat and Mass Transfer, 2012, 48 : 1663 - 1674
  • [25] Influence mechanism on flow and heat transfer characteristics for air-cooled steam condenser cells
    He, Wei Feng
    Dai, Yi Ping
    Li, Mao Qing
    Ma, Qing Zhong
    HEAT AND MASS TRANSFER, 2012, 48 (09) : 1663 - 1674
  • [26] Research on the variation law of the Tube's InsideWall Temperature of Direct Air-Cooled Condenser
    Zhou, Linshu
    Yan, Bo
    Lu, Xiaogang
    Liang, Ming
    Guo, Yueming
    Yuan, Qi
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [27] Coupled flow-field calculation of a direct air-cooled condenser's component unit
    Zhou, Wen-Ping
    Tang, Sheng-Li
    Dongli Gongcheng/Power Engineering, 2007, 27 (05): : 766 - 770
  • [28] Numerical study on spray humidification system used in the direct air-cooled unit
    Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Baoding 071003, China
    Zhongguo Dianji Gongcheng Xuebao, 2008, 29 (28-33):
  • [29] Experimental research on spray evaporative cooling system applied to air-cooled chiller condenser
    Yang, Hua
    Rong, Lan
    Liu, Xuanchen
    Liu, Liansheng
    Fan, Man
    Pei, Na
    ENERGY REPORTS, 2020, 6 : 906 - 913
  • [30] Performance Research of Air-Cooled Heat Pump for Small Residential
    Zheng, Hui-Fan
    Yang, Chun-Li
    Li, Yan-Hua
    Liang, Yao-Hua
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1180 - 1183