Performance Evaluation of a Photovoltaic-Thermal Collector Coupled Stepped Solar Still for Indian Climatic Conditions

被引:0
|
作者
Narang, Ayush [1 ]
Roy, Siddhartha [1 ]
Kataray, Tarun [1 ]
Bonde, Vishal [1 ]
Rajesh, S. [1 ]
Chiranjeevi, C. [1 ]
Chadha, Utkarsh [1 ,2 ]
Hirpha, Bulcha Bekele [3 ]
机构
[1] School of Mechanical Engineering, Vellore Institute of Technology, Vellore, India
[2] Department of Materials Science and Engineering, Faculty of Applied Sciences and Engineering, School of Graduate Studies, University of Toronto, Toronto,ON,M5S 2Z9, Canada
[3] College of Natural and Computational Science, Department of Physics, Dambi Dollo University, Dembi Dolo, Ethiopia
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Freshwater scarcity is increasing across many parts of the globe; to meet this demand, seawater desalination is the best choice, and the electrical energy consumption is escalating due to urbanization and industrialization. Sustainable production of electricity and freshwater can be met by an integrating photovoltaic-thermal (PVT) module with stepped solar still (SSS). The present study focuses on the theoretical modeling of the PVT-SSS desalination system for evaluating thermal efficiency, energy efficiency, freshwater productivity, and electrical power generation. The solar still productivity will be influenced by the depth of water, insulation thickness, glass cover material, thickness and inclination, and operational factors like preheating the input water supply and water salinity. A comparative analysis has been made of summer, winter, and rainy climatic conditions of Vellore town (12.9165° N, 79.1325° E), Tamil Nadu. In the present work, a thermodynamic model based on mass and energy balance is developed for the PVT-SSS system, and it is solved by a numerical method. A Runge-Kutta technique of 4th order is employed using a Python program for solving the thermodynamic simulation model. The results from the model depict that for summer, winter, and rainy climatic seasons, the freshwater productivity of PV/T-SSS was determined to be 12.18 kg/m2day, 6.67 kg/m2day, and 2.77 kg/m2day. Also, it is found that electrical efficiency for summer, winter, and rainy seasons is 8.91%, 9.135%, and 9.53%, respectively. A maximum and minimum freshwater production of 1668 kg/m2 and 1218 kg/m2 are observed for a depth of 2 cm and 5 cm, respectively. © 2022 Ayush Narang et al.
引用
收藏
相关论文
共 50 条
  • [31] Performance study on a photovoltaic thermal (PV/T) stepped solar still with it a bottom channel
    Xiao, Lan
    Shi, Run
    Wu, Shuang-Ying
    Chen, Zhi-Li
    DESALINATION, 2019, 471
  • [32] Performance evaluation of ORC system using evacuated flat plate Photovoltaic-Thermal collector as an evaporator
    Qureshi, Izaz Ahmad
    Waqas, Adeel
    Ali, Majid
    Mehmood, Aamir
    Javed, Adeel
    SOLAR ENERGY, 2021, 230 : 859 - 873
  • [33] Performance Evaluation of the Air-Type Photovoltaic-Thermal Collector Combined with Transverse Triangle Obstacle
    Choi, Hwi-Ung
    Choi, Kwang-Hwan
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2023, 2023
  • [34] Design, modeling and performance monitoring of a photovoltaic-thermal (PVT) water collector
    Aste, Niccolo
    Leonforte, Fabrizio
    Del Pero, Claudio
    SOLAR ENERGY, 2015, 112 : 85 - 99
  • [35] Performance of buildings integrated with a photovoltaic-thermal collector and phase change materials
    Zhou, Yuekuan
    Liu, Xiaohong
    Zhang, Guoqiang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1337 - 1343
  • [36] Performance evaluation of a novel solar photovoltaic-thermal collector with dual channel using microencapsulated phase change slurry as cooling fluid
    Liu, Lingkun
    Jia, Yuting
    Lin, Yaxue
    Alva, Guruprasad
    Fang, Guiyin
    ENERGY CONVERSION AND MANAGEMENT, 2017, 145 : 30 - 40
  • [37] Numerical analysis of performance of a building integrated photovoltaic-thermal collector system
    Corbin, Charles D.
    Zhai, John
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 421 - 428
  • [38] Effect of Thermoelectric Cooling System on the Performance of Photovoltaic-Thermal Collector: A Review
    Zaini, Muhammad Ibrahim Ali
    Mustapha, Muslizainun
    Rosli, Nurul Nazli
    Abd Mutalib, Muhazri
    Nazri, Nurul Syakirah
    Sulong, Wan Mustafa Wan
    Fudholi, Ahmad
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2024, 14 (03): : 674 - 684
  • [39] Design, development and performance monitoring of a photovoltaic-thermal (PVT) air collector
    Aste, Niccolo
    Chiesa, Giancarlo
    Verri, Francesco
    RENEWABLE ENERGY, 2008, 33 (05) : 914 - 927
  • [40] Performance Study of Photovoltaic-Thermal (PV/T) Solar Collector with del-Grooved Absorber Plate
    Othman, Mohd. Yusof Hj.
    Ruslan, Hafidz
    Sopian, Kamaruzzaman
    Jin, Goh Li
    SAINS MALAYSIANA, 2009, 38 (04): : 537 - 541