Research on quantitative evaluation of infrared thermography

被引:0
|
作者
Tian, Yupeng
Zhou, Keyin
Liang, Hua
Liang, Bin
Yang, Ruyi
Yu, Shenglin
机构
[1] College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
[2] College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
[3] Nanjing Boiler and Pressure Vessel Supervision and Inspection Institute, Nanjing 210001, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In the paper, quantitative evaluation of infrared thermography is studied. Based on the heat conduction model, the relation between defect depth and time is analyzed. The concepts of initial separation time point and maximum contrast changing time point are given and their relationship with defect depth is built. Comparison with maximum contrast time point is made. The influence of defect size, external heat stimulation intensity and duration on acquired defect depth is analyzed. The changing rule of defect size is found and the best measurement time region is given. In addition, the time points of the start and end of stimulation are determined by averaging the intensity of image sequences, which sets up the base origination time point for the evaluation of defect depth.
引用
收藏
页码:2413 / 2418
相关论文
共 50 条
  • [41] Verification of quantitative infrared thermography heat-flux measurements
    Rataczak, Jens A.
    Running, Carson L.
    Juliano, Thomas J.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2021, 121
  • [42] A general quantitative identification algorithm of subsurface defect for infrared thermography
    Fan, CL
    Sun, FR
    Yang, L
    [J]. IRMMW-THz2005: The Joint 30th International Conference on Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, Vols 1 and 2, 2005, : 341 - 342
  • [43] Infrared thermography in material research - A review of textile applications
    Banerjee, D.
    Chattopadhyay, S. K.
    Tuli, Suneet
    [J]. INDIAN JOURNAL OF FIBRE & TEXTILE RESEARCH, 2013, 38 (04) : 427 - 437
  • [44] INFRARED THERMOGRAPHY AS AN EFFECTIVE TOOL FOR RESEARCH AND INDUSTRIAL APPLICATION
    Venger, Ye F.
    Dunaievsky, V., I
    Kotovskyi, V. Yo
    Bolgarska, S., V
    Kyslyi, V. P.
    Tymofeyev, V., I
    Orel, V. E.
    Nazarchuk, S. S.
    [J]. SCIENCE AND INNOVATION, 2021, 17 (05): : 20 - 33
  • [45] Infrared contrast data analysis method for quantitative measurement and monitoring in flash infrared thermography
    Koshti, Ajay M.
    [J]. STRUCTURAL HEALTH MONITORING AND INSPECTION OF ADVANCED MATERIALS, AEROSPACE, AND CIVIL INFRASTRUCTURE 2015, 2015, 9437
  • [46] AN EVALUATION OF INFRARED THERMOGRAPHY FOR DETECTION OF BUMBLEFOOT (PODODERMATITIS) IN PENGUINS
    Duncan, Ann E.
    Torgerson-White, Lauri L.
    Allard, Stephanie M.
    Schneider, Tom
    [J]. JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2016, 47 (02) : 474 - 485
  • [47] Investigation on nondestructive evaluation of pipelines using infrared thermography
    Fan, CL
    Sun, FR
    Yang, L
    [J]. IRMMW-THz2005: The Joint 30th International Conference on Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, Vols 1 and 2, 2005, : 339 - 340
  • [48] Application of infrared thermography technique in building finish evaluation
    Li, ZJ
    Yao, W
    Lee, S
    Lee, C
    Yang, ZY
    [J]. JOURNAL OF NONDESTRUCTIVE EVALUATION, 2000, 19 (01) : 11 - 19
  • [49] Cumulative damage evaluation of steel using infrared thermography
    Risitano, A.
    Risitano, G.
    [J]. THEORETICAL AND APPLIED FRACTURE MECHANICS, 2010, 54 (02) : 82 - 90
  • [50] INFRARED THERMOGRAPHY ANALYSIS OF AN INTERFACIAL CRACK AND ITS EVALUATION
    ITO, Y
    SAITO, M
    KASHIWAYA, H
    OISHI, M
    KANEKO, T
    [J]. NIPPON SERAMIKKUSU KYOKAI GAKUJUTSU RONBUNSHI-JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1989, 97 (11): : 1358 - 1364