Vibration-compensated interferometer for surface metrology

被引:0
|
作者
Zhao, Chunyu [1 ]
Burge, James H. [1 ]
机构
[1] Optical Sciences Center, University of Arizona, 1630 E. University Boulevard, Tucson, AZ 85721, United States
来源
Applied Optics | 2001年 / 40卷 / 34期
关键词
Electrooptical effects - Phase modulation - Surface measurement - Vibrations (mechanical);
D O I
10.1364/ao.40.006215
中图分类号
学科分类号
摘要
An advanced interferometer was built for surface metrology in environments with severe vibration. This instrument uses active control to compensate for effects of vibration to allow surface measurement with high-resolution phase-shifting interferometry. A digital signal processor and high-speed phase control from an electro-optic modulator allows phase measurements at 4000 Hz. These measurements are fed back into a real-time servo in the digital signal processor that provides a vibration-corrected phase ramp for the surface measurements taken at video rates. Unlike fringe locking, which compensates vibration to keep the phase constant, we show a true phase servo that allows the phase to be stabilized while it is ramped, enabling surface measurements using phase-shifting interferometry that requires multiple images with controlled phase shifts. © 2001 Optical Society of America.
引用
收藏
页码:6215 / 6222
相关论文
共 50 条
  • [1] Vibration-compensated interferometer for surface metrology
    Zhao, CY
    Burge, JH
    APPLIED OPTICS, 2001, 40 (34) : 6215 - 6222
  • [2] Vibration-compensated interferometer for measuring cryogenic mirrors
    Zhao, CY
    Burge, JH
    OPTICAL MANUFACTURING AND TESTING III, 1999, 3782 : 399 - 406
  • [3] DEVELOPMENT OF A VIBRATION-COMPENSATED CO2 INTERFEROMETER FOR THE RFX EXPERIMENT
    INNOCENTE, P
    MARTINI, S
    SCHIO, A
    ROCA, CF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2885 - 2887
  • [4] Transverse spatial phase-shifting method used in vibration-compensated interferometer
    Wu, D
    Zhu, RH
    Chen, L
    Li, JY
    OPTIK, 2004, 115 (08): : 343 - 346
  • [5] REAL-TIME, VIBRATION-COMPENSATED CO2 INTERFEROMETER OPERATION ON THE DIII-D TOKAMAK
    CARLSTROM, TN
    AHLGREN, DR
    CROSBIE, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (07): : 1063 - 1066
  • [6] Atmospheric metrology using the air turbulence compensated interferometer
    Henshaw, PD
    DeGloria, DP
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (06): : 3955 - 3959
  • [7] VIBRATION COMPENSATED PORTABLE INTERFEROMETER SYSTEM
    SPECTOR, DN
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (08): : 890 - 890
  • [8] AN INFRARED VIBRATION COMPENSATED INTERFEROMETER FOR THE MST EXPERIMENT
    INNOCENTE, P
    MARTINI, S
    ROCA, CF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10): : 4999 - 5001
  • [9] Vibration-compensated interferometry system using phase-modulating interference fringe subdivision technology
    He, Liangfang
    APPLIED OPTICS, 2006, 45 (31) : 7987 - 7992
  • [10] Phase error correction method for a vibration compensated interferometer
    Van Zeeland, MA
    Carlstrom, TN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3423 - 3425