Scalability Assessment of the Parallel Operation of Direct Current Transformer

被引:0
|
作者
Barcelos R.P. [1 ]
Dujic D. [1 ]
机构
[1] Power Electronics Laboratory, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
Current sharing; direct current transformer (DCT); impedance; LLC converter; parallel operation; resonant converter;
D O I
10.24295/CPSSTPEA.2023.00030
中图分类号
学科分类号
摘要
Paralleling duty-cycle controlled high-power con- verters is well understood while achieving the same with un- controlled resonant converters poses certain challenges. In order to predict the current sharing unbalance after paralleling several direct current transformers, this paper proposes a methodology to define the quality of the parallel connection considering system -level parameters. Based on the input impedance of the small signal model, critical parameters are identified, and the impact of the different levels of parameter variation on the current sharing of direct current transformers is evaluated. Then, design constraints based on the model are set to achieve satisfying current sharing considering the resultant input impedance. Further, the impact of the switching frequency, considered the only design degree of freedom, on the input impedance is used to modify the current sharing between the modules. Modeling and predictions are verified by means of simulation and experimental investigations. © 2023 China Power Supply Society. All rights reserved.
引用
收藏
页码:397 / 410
页数:13
相关论文
共 50 条
  • [31] Investigation of the Influence of Direct Current Bias on Transformer Vibration
    Wang, Jun
    Liu, Hongshun
    Niu, Kaicheng
    Wu, Zemin
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2018, 19 (03)
  • [32] A simple circuit for direct current measurement using a transformer
    Pejovic, P
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 1998, 45 (08) : 830 - 837
  • [33] A DIRECT CURRENT INSTRUMENT TRANSFORMER USING REED RELAYS
    MORETON, PL
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (08): : 721 - &
  • [34] ELECTROSTATIC DIRECT-CURRENT TRANSFORMER OF 300 KILOVOLTS
    MALPICA, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1951, 22 (06): : 364 - 369
  • [35] Tests of optical fiber current transformer for direct currents
    Hino, M
    Hase, S
    Akagi, M
    PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 284 - 286
  • [36] A scheme for detection and assessment of current transformer saturation
    Chen Hong
    Liu Haifeng
    Jiang Hui
    Peng Jianchun
    Huang Chun
    PROCEEDINGS OF 2017 9TH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA), 2017, : 90 - 93
  • [38] Experimental Operation of the Adaptive Electronic Instrument Transformer of Current and Voltage
    Volovich, G., I
    Kirpichnikova, I. M.
    Topolskiy, D., V
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [39] Operation Reliability of Optical Current Transformer Based on Synthetic Probability
    Xiao Y.
    Li J.
    Pang F.
    Xu J.
    Dianwang Jishu/Power System Technology, 2022, 46 (01): : 336 - 342
  • [40] The Application of Inrush Current Restraining Technology in Transformer Economic Operation
    Yang Yong
    Liu Zhizhen
    Cong Min
    Qi Guozheng
    Hu Gang
    2015 18TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2015, : 1386 - 1389