An evaluation of selective grounding fault protective relaying technique performance on the ungrounded DC traction power supply system

被引:1
|
作者
Korea Railroad Research Institute, Korea, Republic of [1 ]
不详 [2 ]
机构
来源
Trans. Korean Inst. Electr. Eng. | 2012年 / 12卷 / 1964-1969期
关键词
D O I
10.5370/KIEE.2012.61.12.1964
中图分类号
学科分类号
摘要
This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.
引用
收藏
相关论文
共 50 条
  • [21] DC Auto-Transformer Traction Power Supply System for DC Railways Application
    Wang, Miao
    Yang, Xiaofeng
    Wang, Lulu
    Zheng, Trillion Q.
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES FOR RAIL TRANSPORTATION (EITRT) 2017: ELECTRICAL TRACTION, 2018, 482 : 175 - 184
  • [22] A Novel DC Microgrid Based on Photovoltaic and Traction Power Supply System
    Meng, Ming
    Yuan, Yaning
    Guo, Mingwei
    Jiang, Li
    Liu, Jian
    Hu, Dalong
    Cong, Haiyang
    Hao, Dan
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [23] Hybrid Bidirectional Interactive DC Traction Power Supply System with Microgrid
    Meng, Ming
    Yuan, Yaning
    Guo, Mingwei
    Jiang, Li
    Liu, Jian
    Hu, Dalong
    Cong, Haiyang
    Hao, Dan
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [24] Reliability Analysis of DC Traction Power Supply System for Electric Railway
    Hayashiya, Hitoshi
    Masuda, Masayoshi
    Noda, Yukihisa
    Suzuki, Koichiro
    Suzuki, Takashi
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [25] Operating state monitoring and fault diagnosis on traction power supply system
    Li Xiaqing
    Fan Shengtao
    Lu Yanqing
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 866 - +
  • [26] Research of Fault Location Method for Metro Traction Power Supply System
    Song, Xiaoming
    He, Jinghan
    Yip, Tony
    Kirby, Brian
    Yang, Xia
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES FOR RAIL TRANSPORTATION (EITRT2013), VOL II, 2014, 288 : 137 - 146
  • [27] Implementation of information system for protective relaying and fault recorder in Henan power network
    Liu, Hua
    Bai, Yi-Chuan
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2006, 30 (09): : 84 - 87
  • [28] A novel technique for measuring grounding capacitance and grounding fault resistance in ineffectively grounded power system
    Zeng, XJ
    Yin, XG
    Zhang, Z
    Chen, DS
    Yu, YY
    INTERNATIONAL CONFERENCE ON SENSORS AND CONTROL TECHNIQUES (ICSC 2000), 2000, 4077 : 324 - 327
  • [29] An influence of a complex modernization of the DC traction power supply on the parameters of an electric power system
    Wojciechowski, Jerzy
    Lorek, Krzysztof
    Nowakowski, Waldemar
    13TH INTERNATIONAL CONFERENCE MODERN ELECTRIFIED TRANSPORT - MET'2017, 2018, 180