Maximizing microcalcification detectability in low-dose dedicated cone-beam breast CT: parallel cascades-based theoretical analysis

被引:0
|
作者
Larsen, Thomas [1 ]
Tseng, Hsin Wu [2 ]
Trinate, Rachawadee
Fu, Zhiyang [2 ]
Alan Chiang, Jing-Tzyh [2 ]
Karellas, Andrew [2 ]
Vedantham, Srinivasan [1 ,2 ]
机构
[1] Univ Arizona, Dept Biomed Engn, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Med Imaging, Tucson, AZ 85721 USA
基金
美国国家卫生研究院;
关键词
breast cancer; breast CT; numerical observers; microcalcifications; cascaded systems; DIGITAL MAMMOGRAPHY; AMERICAN-COLLEGE; PERFORMANCE; RESOLUTION; MODEL; RECONSTRUCTION; SPECTRUM; NETWORK; SIGNAL; TOOL;
D O I
10.1117/1.JMI.11.3.033501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We aim to determine the combination of X-ray spectrum and detector scintillator thickness that maximizes the detectability of microcalcification clusters in dedicated cone-beam breast CT. Approach: A cascaded linear system analysis was implemented in the spatial frequency domain and was used to determine the detectability index using numerical observers for the imaging task of detecting a microcalcification cluster with 0.17 mm diameter calcium carbonate spheres. The analysis considered a thallium-doped cesium iodide scintillator coupled to a complementary metal-oxide semiconductor detector and an analytical filtered-back-projection reconstruction algorithm. Independent system parameters considered were the scintillator thickness, applied X-ray tube voltage, and X-ray beam filtration. The combination of these parameters that maximized the detectability index was considered optimal. Results: Prewhitening, nonprewhitening, and nonprewhitening with eye filter numerical observers indicate that the combination of 0.525 to 0.6 mm thick scintillator, 70 kV, and 0.25 to 0.4 mm added copper filtration maximized the detectability index at a mean glandular dose (MGD) of 4.5 mGy. Conclusion: Using parallel cascade systems' analysis, the combination of parameters that could maximize the detection of microcalcifications was identified. The analysis indicates that a harder beam than that used in current practice may be beneficial for the task of detecting microcalcifications at an MGD suitable for breast cancer screening. (c) 2024 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Low-Dose Phase-Correlated Cone-Beam Micro-CT of Small Animals
    Sawall, Stefan
    Bergner, Frank
    Lapp, Robert
    Mronz, Markus
    Karolczak, Marek
    Hess, Andreas
    Kachelriess, Marc
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2046 - 2050
  • [22] Compressed Sensing with a First-Order Method for Low-Dose Cone-Beam CT Reconstruction
    Choi, K.
    Wang, J.
    Zhu, L.
    Suh, T.
    Boyd, S.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06) : 3442 - +
  • [23] Radiation Dose Reduction and Image Quality Evaluation of Coronal Truncated Projections in Cone-Beam Dedicated Breast CT
    Konate, S.
    Vedantham, S.
    Shi, L.
    Karellas, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Dedicated cone-beam breast CT: Data acquisition strategies based on projection angle-dependent normalized glandular dose coefficients
    Tseng, Hsin Wu
    Karellas, Andrew
    Vedantham, Srinivasan
    MEDICAL PHYSICS, 2023, 50 (03) : 1406 - 1417
  • [25] Improving Cone-Beam CT Angiography for Prostatic Artery Embolization: Is a Low-Dose Protocol Equivalent to the Standard?
    Uflacker, Andre
    Haskal, Ziv J.
    Patrie, James
    Smith, Alex
    Tramel, Richard
    Irish, Nolan
    Ashley, Bryan
    Johnson, David T.
    Yamada, Ricardo
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 32 (04) : 562 - 568
  • [26] Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies
    Liu, Wenlei
    Rong, Junyan
    Gao, Peng
    Liao, Qimei
    Lu, HongBing
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [27] Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy
    Gao, Liugang
    Xie, Kai
    Wu, Xiaojin
    Lu, Zhengda
    Li, Chunying
    Sun, Jiawei
    Lin, Tao
    Sui, Jianfeng
    Ni, Xinye
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [28] Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy
    Liugang Gao
    Kai Xie
    Xiaojin Wu
    Zhengda Lu
    Chunying Li
    Jiawei Sun
    Tao Lin
    Jianfeng Sui
    Xinye Ni
    Radiation Oncology, 16
  • [29] Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT
    Yoo, B.
    Pua, R.
    Kim, J.
    Cho, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [30] An object-specific and dose-sparing scatter correction approach for a dedicated cone-beam breast CT system using a parallel-hole collimator
    Yang, Kai
    Burkett, George, Jr.
    Boone, John M.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313