Maximizing microcalcification detectability in low-dose dedicated cone-beam breast CT: parallel cascades-based theoretical analysis

被引:0
|
作者
Larsen, Thomas [1 ]
Tseng, Hsin Wu [2 ]
Trinate, Rachawadee
Fu, Zhiyang [2 ]
Alan Chiang, Jing-Tzyh [2 ]
Karellas, Andrew [2 ]
Vedantham, Srinivasan [1 ,2 ]
机构
[1] Univ Arizona, Dept Biomed Engn, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Med Imaging, Tucson, AZ 85721 USA
基金
美国国家卫生研究院;
关键词
breast cancer; breast CT; numerical observers; microcalcifications; cascaded systems; DIGITAL MAMMOGRAPHY; AMERICAN-COLLEGE; PERFORMANCE; RESOLUTION; MODEL; RECONSTRUCTION; SPECTRUM; NETWORK; SIGNAL; TOOL;
D O I
10.1117/1.JMI.11.3.033501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We aim to determine the combination of X-ray spectrum and detector scintillator thickness that maximizes the detectability of microcalcification clusters in dedicated cone-beam breast CT. Approach: A cascaded linear system analysis was implemented in the spatial frequency domain and was used to determine the detectability index using numerical observers for the imaging task of detecting a microcalcification cluster with 0.17 mm diameter calcium carbonate spheres. The analysis considered a thallium-doped cesium iodide scintillator coupled to a complementary metal-oxide semiconductor detector and an analytical filtered-back-projection reconstruction algorithm. Independent system parameters considered were the scintillator thickness, applied X-ray tube voltage, and X-ray beam filtration. The combination of these parameters that maximized the detectability index was considered optimal. Results: Prewhitening, nonprewhitening, and nonprewhitening with eye filter numerical observers indicate that the combination of 0.525 to 0.6 mm thick scintillator, 70 kV, and 0.25 to 0.4 mm added copper filtration maximized the detectability index at a mean glandular dose (MGD) of 4.5 mGy. Conclusion: Using parallel cascade systems' analysis, the combination of parameters that could maximize the detection of microcalcifications was identified. The analysis indicates that a harder beam than that used in current practice may be beneficial for the task of detecting microcalcifications at an MGD suitable for breast cancer screening. (c) 2024 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Low-Dose Cone-Beam Breast CT: Physics and Technology Development
    Boone, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3829 - 3830
  • [2] Low-Dose Cone-Beam Dedicated Breast CT: Self-Supervised Denoising From Single Image
    Fu, Z.
    Tseng, H.
    Karellas, A.
    Vedantham, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E636 - E636
  • [3] Moving Beam-Blocker-Based Low-Dose Cone-Beam CT
    Lee, Taewon
    Lee, Changwoo
    Baek, Jongduk
    Cho, Seungryong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (05) : 2540 - 2549
  • [4] Preliminary Investigation of Dose Allocation in Low-dose Cone-beam CT
    Han, Xiao
    Pearson, Erik
    Bian, Junguo
    Cho, Seungryong
    Sidky, Emil Y.
    Pelizzari, Charles A.
    Pan, Xiaochuan
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2051 - 2054
  • [5] Low-dose megavoltage cone-beam CT for radiation therapy
    Pouliot, J
    Bani-Hashemi, A
    Chen, J
    Svatos, M
    Ghelmansarai, F
    Mitschke, M
    Aubin, M
    Xia, P
    Morin, O
    Bucci, K
    Roach, M
    Hernandez, P
    Zheng, ZR
    Hristov, D
    Verhey, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (02): : 552 - 560
  • [6] Simulating low-dose cone-beam CT: a phantom study
    Ferrero, Andrea
    Fetterly, Ken
    Yu, Lifeng
    Schueler, Beth
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [7] Low-dose Quantitative Cone-beam CT Imaging in Radiation Therapy
    Niu, Tianye
    Zhu, Lei
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2907 - 2909
  • [8] Improved scatter compensation method for low-dose cone-beam CT in SPECT/CT
    Wang, Jiong
    Wiegert, Jens
    Hansis, Eberhard
    Bredno, Joer
    Sowards-Emmerd, David
    Shao, Lingxiong
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [9] Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis?
    de Lima, Joao Pedro
    Mazzi-Chaves, Jardel Francisco
    de Sousa-Neto, Manoel Damiao
    Candemil, Amanda Pelegrin
    JOURNAL OF ENDODONTICS, 2023, 49 (09) : 1161 - 1168
  • [10] Optimization of a Collimator-Based Sparse Sampling Technique for Low-Dose Cone-Beam CT
    Lee, T.
    Kim, I.
    Han, B.
    Cho, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3201 - 3201