Quantification of functional hemodynamics in aortic valve disease using cardiac computed tomography angiography

被引:1
|
作者
Liu X. [1 ]
Guo G. [2 ]
Wang A. [1 ]
Wang Y. [3 ,4 ,5 ,6 ]
Chen S. [3 ,4 ,5 ,6 ]
Zhao P. [3 ,4 ,5 ,6 ]
Yin Z. [3 ,4 ,5 ,6 ]
Liu S. [3 ,4 ,5 ,6 ]
Gao Z. [1 ]
Zhang H. [1 ]
Zu L. [3 ,4 ,5 ,6 ]
机构
[1] School of Biomedical Engineering, Sun Yat-sen University, Shenzhen
[2] Department of Radiology, Peking University Third Hospital, Beijing
[3] Department of Cardiology and Institute of Vascular Medicine, Peking University Third Hospital, Beijing
[4] State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing
[5] NHC Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Peking University, Beijing
[6] Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing
基金
中国国家自然科学基金;
关键词
Aortic valve disease; Computed tomography angiography; Hemodynamic assessment; Image-based modeling; Transvalvular pressure gradient;
D O I
10.1016/j.compbiomed.2024.108608
中图分类号
学科分类号
摘要
Background and Objective: Cardiac computed tomography angiography (CTA) is the preferred modality for preoperative planning in aortic valve stenosis. However, it cannot provide essential functional hemodynamic data, specifically the mean transvalvular pressure gradient (MPG). This study aims to introduce a computational fluid dynamics (CFD) approach for MPG quantification using cardiac CTA, enhancing its diagnostic value. Methods: Twenty patients underwent echocardiography, cardiac CTA, and invasive catheterization for pressure measurements. Cardiac CTA employed retrospective electrocardiographic gating to capture multi-phase data throughout the cardiac cycle. We segmented the region of interest based on mid-systolic phase cardiac CTA images. Then, we computed the average flow velocity into the aorta as the inlet boundary condition, using variations in end-diastolic and end-systolic left ventricular volume. Finally, we conducted CFD simulations using a steady-state model to obtain pressure distribution within the computational domain, allowing for the derivation of MPG. Results: The mean value of MPG, measured via invasive catheterization (MPGInv), echocardiography (MPGEcho), and cardiac CTA (MPGCT), were 51.3 ± 28.4 mmHg, 44.8 ± 19.5 mmHg, and 55.8 ± 25.6 mmHg, respectively. In comparison to MPGInv, MPGCT exhibited a higher correlation of 0.91, surpassing that of MPGEcho, which was 0.82. Moreover, the limits of agreement for MPGCT ranged from −27.7 to 18.7, outperforming MPGEcho, which ranged from −40.1 to 18.0. Conclusions: The proposed method based on cardiac CTA enables the evaluation of MPG for aortic valve stenosis patients. In future clinical practice, a single cardiac CTA examination can comprehensively assess both the anatomical and functional hemodynamic aspects of aortic valve disease. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [1] Objective quantification of aortic valvular structures by cardiac computed tomography angiography in patients considered for transcatheter aortic valve implantation
    Korosoglou, Grigorios
    Gitsioudis, Gitsios
    Waechter-Stehle, Irina
    Weese, Juergen
    Krumsdorf, Ulrike
    Chorianopoulos, Emmanuel
    Hosch, Waldemar
    Kauczor, Hans-Ulrich
    Katus, Hugo A.
    Bekeredjian, Raffi
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (01) : 148 - 159
  • [2] Cardiac computed tomography and computed tomography angiography in the evaluation of patients prior to transcatheter aortic valve implantation
    Nguyen, Giang
    Leipsic, Jonathon
    CURRENT OPINION IN CARDIOLOGY, 2013, 28 (05) : 497 - 504
  • [3] Quantifying Aortic Valve Calcification using Coronary Computed Tomography Angiography
    Alqahtani, Abdulrahman M.
    Boczar, Kevin E.
    Kansal, Vinay
    Chan, Kwan
    Dwivedi, Girish
    Chow, Benjamin J. W.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (02) : 99 - 104
  • [4] AORTIC VALVE CALCIUM QUANTIFICATION USING CONTRAST ENHANCED COMPUTED TOMOGRAPHY
    Shotwell, Matthew K.
    Sankaramangalam, Kesavan
    Potluri, Saipriya
    Zeb, Irfan
    Brito, Daniel
    Kadiyala, Madhavi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1242 - 1242
  • [5] Is routine computed tomography angiography justified in patients undergoing aortic valve replacement for bicuspid aortic valve disease?
    Muthukkumaran S.
    Talwar S.
    Gharde P.
    Sharma S.
    Singh S.
    Choudhary S.K.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2014, 30 (1) : 17 - 21
  • [6] Multislice computed tomography for quantification of aortic valve stenosis
    Feuchtner, G. M.
    Dichtl, W.
    Friedrich, G. J.
    Alber, H.
    Frick, M.
    Nedden, D. zur
    Pachinger, O.
    Mueller, S.
    EUROPEAN HEART JOURNAL, 2005, 26 : 133 - 133
  • [7] Cardiac computed tomography for valve disease
    Cuellar, H.
    Roque, A.
    Pineda, V.
    Rodriguez, J.
    RADIOLOGIA, 2013, 55 (01): : 24 - 36
  • [8] Assessment of coronary artery disease using coronary computed tomography angiography in patients with aortic valve stenosis referred for surgical aortic valve replacement
    Larsen, L. Hornbech
    Kofoed, K. Fuglsang
    Dalsgaard, M.
    Kristensen, T.
    Elming, H.
    Steinbruchel, D. A.
    Kober, L.
    Kelbaek, H.
    Hassager, C.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (01) : 126 - 131
  • [9] Assessment of aortic bioprosthetic valve fracture by Computed Tomography Angiography
    Hashimoto, Go
    Cavalcante, Joao L.
    Mooney, Michael R.
    Burns, Marcus R.
    Ukaigwe, Anene C.
    Garcia, Santiago
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (01) : e7 - e9
  • [10] Aortic Pathology in Patients With Bicuspid Aortic Valve Assessed With Computed Tomography Angiography
    Michalowska, Ilona M.
    Kruk, Mariusz
    Kwiatek, Pawel
    Hryniewiecki, Tomasz
    Kowalski, Miroslaw
    Furmanek, Mariusz I.
    Oleksiuk, Tomasz
    Waniewska, Joanna
    Hoffman, Piotr
    JOURNAL OF THORACIC IMAGING, 2014, 29 (02) : 113 - 117