Assessment of coronary artery disease using coronary computed tomography angiography in patients with aortic valve stenosis referred for surgical aortic valve replacement

被引:15
|
作者
Larsen, L. Hornbech [1 ]
Kofoed, K. Fuglsang [1 ]
Dalsgaard, M. [1 ]
Kristensen, T. [2 ]
Elming, H. [3 ]
Steinbruchel, D. A. [4 ]
Kober, L. [1 ]
Kelbaek, H. [1 ]
Hassager, C. [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Cardiol, DK-2100 Copenhagen O, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Radiol, DK-2100 Copenhagen O, Denmark
[3] Roskilde Hosp, Dept Cardiol, Roskilde, Denmark
[4] Copenhagen Univ Hosp, Rigshosp, Dept Cardiothorac Surg, DK-2100 Copenhagen O, Denmark
关键词
Coronary computed tomography angiography; Aortic valve stenosis; Invasive coronary angiography; Cardiac computed tomography; VALVULAR HEART-DISEASE; TASK-FORCE; GUIDELINES; MANAGEMENT; ACCURACY; SOCIETY; FLOW;
D O I
10.1016/j.ijcard.2012.09.057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In patients referred for aortic valve replacement (AVR) a pre-surgical assessment of coronary artery disease is mandatory to determine the possible need for additional coronary artery bypass grafting. The diagnostic accuracy of coronary computed tomography angiography (coronary CTA) was evaluated in patients with aortic valve stenosis referred for surgical AVR. Methods: Between March 2008 and March 2010 a total of 181 consecutive patients were included. All patients underwent pre-surgical coronary CTA (64- or 320-detector CT scanner) and invasive coronary angiography (ICA). The analyses were performed blinded to each other. Results: The mean +/- SD age of the included patients was 71 +/- 9 years and 59% were male. The prevalence of significant coronary artery stenosis >70% by ICA was 36%. Average heart rate during coronary CTA was 65 +/- 16 bpm. In a patient based analysis 94% of the patients (171/181) were considered fully evaluable. Coronary CTA had a sensitivity of 68%, a specificity of 91%, a positive predictive value of 81%, and a negative predictive value of 83%. Advanced age, obstructive lung disease, NYHA function class III/IV, and high Agatston score were found to be significantly associated with disagreement between ICA and coronary CTA in univariate analysis. Conclusion: In patients with aortic valve stenosis referred for surgical AVR the diagnostic accuracy of coronary CTA to identify significant coronary artery disease is moderate. Coronary CTA may be used successfully in a subset of patients with low age, no chronic obstructive lung disease, NYHA function class<III and low coronary Agatston score. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:126 / 131
页数:6
相关论文
共 50 条
  • [1] Detection of significant coronary artery disease using computed tomography coronary angiography in patients with aortic stenosis referred for surgical aortic valve replacement
    Larsen, L. H.
    Kofoed, K. F.
    Dalsgaard, M.
    Kristensen, T.
    Elming, H.
    Steinbruchel, D. A.
    Koeber, L.
    Kelbaek, H.
    Hassager, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 86 - 86
  • [2] Coronary CT angiography for the detection of coronary artery stenosis in patients referred for transcatheter aortic valve replacement
    Hamdan, Ashraf
    Wellnhofer, Ernst
    Konen, Eli
    Kelle, Sebastian
    Goitein, Orly
    Andrada, Bogdan
    Raanani, Ehud
    Segev, Amit
    Barbash, Israel
    Klempfner, Robert
    Goldenberg, Ilan
    Guetta, Victor
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (01) : 31 - 41
  • [3] DIAGNOSTIC ACCURACY OF CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY IN AORTIC STENOSIS PATIENTS REFERRED FOR AORTIC VALVE REPLACEMENT: SYSTEMATIC REVIEW AND META-ANALYSIS
    Chaikriangkrai, Kongkiat
    Shantha, Ghanshyam Palamaner Subash
    Bin Abdulhak, Aref
    Tandon, Rudhir
    Alqasrawi, Musab
    Jhun, Hye Yeon
    Sigurdsson, Gardar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1507 - 1507
  • [4] Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    Opolski, Maksymilian P.
    Kim, Won-Keun
    Liebetrau, Christoph
    Walther, Claudia
    Blumenstein, Johannes
    Gaede, Luise
    Kempfert, Joerg
    Van Linden, Arnaud
    Walther, Thomas
    Hamm, Christian W.
    Moellmann, Helge
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (06) : 471 - 480
  • [5] Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    Opolski, M. P.
    Kim, W. K.
    Walther, C.
    Walther, T.
    Blumenstein, J.
    Liebetrau, C.
    Gaede, L.
    Kempfert, J.
    Hamm, C. W.
    Moellmann, H.
    EUROPEAN HEART JOURNAL, 2014, 35 : 715 - 716
  • [6] Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    Maksymilian P. Opolski
    Won-Keun Kim
    Christoph Liebetrau
    Claudia Walther
    Johannes Blumenstein
    Luise Gaede
    Jörg Kempfert
    Arnaud Van Linden
    Thomas Walther
    Christian W. Hamm
    Helge Möllmann
    Clinical Research in Cardiology, 2015, 104 : 471 - 480
  • [7] A Preoperative Assessment of Significant Coronary Stenosis Based on a Semiquantitative Analysis of Coronary Artery Calcification on Noncontrast Computed Tomography in Aortic Stenosis Patients Undergoing Aortic Valve Replacement
    Hwang, Ji-Won
    Kim, Sung Mok
    Park, Sung-Ji
    Cho, Eun Jeong
    Lee, Sans-Chol
    Choe, Yeon Hyeon
    Park, Seung Woo
    MEDICINE, 2016, 95 (09)
  • [8] Coronary Artery Disease and Outcomes of Aortic Valve Replacement for Severe Aortic Stenosis
    Beach, Jocelyn M.
    Mihaljevic, Tomislav
    Svensson, Lars G.
    Rajeswaran, Jeevanantham
    Marwick, Thomas
    Griffin, Brian
    Johnston, Douglas R.
    Sabik, Joseph F., III
    Blackstone, Eugene H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (08) : 837 - 848
  • [9] Accuracy of multislice computed tomography in the preoperative assessment of coronary disease in patients with aortic valve stenosis
    Gilard, M
    Cornily, JC
    Pennec, PY
    Joret, C
    Le Gal, G
    Mansourati, J
    Blanc, JJ
    Boschat, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (10) : 2020 - 2024
  • [10] Accuracy of multislice computed tomography in the preoperative assessment of coronary disease in patients with aortic valve stenosis
    Gilard, M.
    Cornily, J. -C.
    Pennec, P. -Y.
    Le Gal, G.
    Joret, C.
    M, J.
    Boschat, J.
    EUROPEAN HEART JOURNAL, 2006, 27 : 431 - 431